NautemyCoC orals · exams · job testsEarly access
Oral topic41 min readJump to 38 questions

Fire-fighting oral exam questions and model answers for deck officers

Fire-fighting oral questions ask what you would do, step by step, when a fire breaks out, then probe the SOLAS Chapter II-2 and FSS Code numbers behind your actions. Learn the sequence (alarm, contain, attack, boundary cool, account for people) and the key figures below.

On this page
  1. Key facts
  2. What do examiners ask about fire-fighting at each rank?
  3. What fire science must you know for the oral?
  4. Which SOLAS Chapter II-2 and FSS Code numbers do examiners expect?
  5. How often must fire-fighting equipment be tested and inspected?
  6. How should you structure a fire-fighting answer?
  7. How often are fire drills held and what must they include?
  8. What changed in fire safety rules in 2024–2026?
  9. What mistakes make candidates fail fire-fighting questions?
  10. Which fire scenarios should you rehearse?
  11. How do you calculate CO2 quantity, spare charges and emergency fire pump capacity?
  12. How do you walk through a fire scenario in the oral?
  13. What do weak and strong fire-fighting answers sound like?
  14. What should you read to revise fire-fighting?
  15. 38 practice questions
  16. Frequently asked questions
  17. Sources

Key facts

Main rules
SOLAS Ch. II-2, FSS Code, SOLAS Reg. III/19 (drills)
Examined at
2nd mate, chief mate and master orals (India MMD, UK MCA and others)
Maintenance guide
MSC.1/Circ.1432 (weekly to ten-yearly)[1]
CO2 system guide
MSC.1/Circ.1318/Rev.1 (2021)[2]
Portable extinguishers
A.951(23): service yearly, discharge test 5-yearly, hydraulic test 10-yearly[3]
Fire drills (cargo ship)
Every crew member at least once a month (SOLAS III/19)
Latest change
PFOS foam banned from 1 Jan 2026[4]
Practice
38 oral questions below plus a free MCQ bank

Checked 14 November 2026. Fees and rules change: confirm with the authority before you book.

What do examiners ask about fire-fighting at each rank?

Examiners at every level ask what you would do when a fire starts; the difference is depth. A second mate must act correctly and know the equipment. A chief mate must organise the fire party and maintenance. A master must decide, communicate and protect the ship and crew.

Fire-fighting sits in the safety function of the oral at every rank: the 2nd mate oral in India, the MCA OOW deck oral, the chief mate oral, the MCA chief mate oral, the master oral and the MCA master oral. It overlaps with SOLAS, emergency procedures and, on tankers, tanker operations.

Depth expected by rank
RankWhat the examiner wantsTypical question
Second mate / OOW (operational level)Fire chemistry, classes of fire, extinguisher choice, what is on your ship and where, first actions as OOW, muster and drills, fireman's outfit, EEBD, fire control planThe fire alarm panel shows a fire in the engine room at 0200. What do you do?
Chief mate (management level)Organising fire parties, boundary cooling, cargo hold and tanker fires, fixed systems (CO2, foam, water mist), maintenance plan under MSC.1/Circ.1432, drill planning and training records, stability effect of fire-fighting waterHow do you plan and record fire drills, and what do you check monthly on the fire main?
MasterCommand decisions: when to release CO2, when to call shore help, port of refuge, communication with company, flag and coastal state, crew welfare, abandoning ship, legal recordsFire in a container hold 200 miles from port. Talk me through your decisions for the next 24 hours.

What fire science must you know for the oral?

You must explain how a fire starts and how each extinguishing medium stops it. Examiners start here because every later answer (why CO2, why foam, why boundary cooling) depends on it.

  • Fire triangle: fuel, heat and oxygen. Remove one and the fire goes out. The fire tetrahedron adds the uninhibited chain reaction, which dry powder and some gaseous agents break.
  • Flash point: the lowest temperature at which a liquid gives off enough vapour to form a flammable mixture that flashes when a flame is applied. Fire point is a little higher; the vapour keeps burning. Auto-ignition temperature is the temperature at which the vapour ignites with no flame or spark.
  • Methods: starving (remove fuel, close valves), smothering (exclude oxygen: foam, CO2, blanket), cooling (water), and chain-breaking (dry powder).
  • Heat transfer: conduction through steel bulkheads, convection through ducts and stairways, radiation across open spaces. This is why you boundary-cool on all six sides of a compartment.
  • Classes of fire: the letters depend on the standard. Under ISO/EN use: A solids, B flammable liquids, C gases, D metals, F cooking oils; electrical fire is a hazard, not a class. Under US NFPA, class C means energised electrical equipment. Say which system you use.
Extinguishing agents and how they work
AgentMain actionUse onDo not use on
Water (jet, spray, fog)Cooling; fog also smothers by steamClass A, boundary coolingLive electrical equipment; burning oil with a jet
Foam (low expansion)Smothering blanket, some coolingOil spills, tank tops, bilgesLive electrics; some foams break down on alcohols (use alcohol-resistant foam)
High-expansion foamFills the space, smothersMachinery spaces, holdsSpaces where people are still inside
CO2Smothering by reducing oxygenElectrical, machinery spaces, holdsAccommodation (extinguishers not stowed there); self-oxygenating cargoes
Dry powderBreaks chain reaction, some smotheringLiquids, gases, electricalSensitive electronics if avoidable; it does not cool, so re-ignition is a risk
Wet chemicalCools and forms a soap layerCooking oil (class F)Electrical

Which SOLAS Chapter II-2 and FSS Code numbers do examiners expect?

Know the figures in the table below exactly; examiners use them to check whether you have read the rules or only a guidebook. All come from SOLAS Reg. II-2/10 and the FSS Code; quote the chapter when you answer.

Also know the structure of SOLAS Chapter II-2: Part A general (Regs 1–3), Part B prevention of fire and explosion (4–6), Part C suppression of fire (7–11), Part D escape (12–13), Part E operational requirements (14–16), Part F alternative design (17), Part G special requirements (18–20, including helicopter facilities, dangerous goods and ro-ro spaces). Reg. 10 is fire-fighting, Reg. 13 means of escape, Reg. 14 operational readiness and maintenance, Reg. 15 instructions, training and drills, Reg. 16 operations.

Must-know fire-fighting numbers (SOLAS II-2 and FSS Code)
ItemRequirementReference
Fire pumps, cargo ship 1,000 GT and overAt least two independently driven pumpsSOLAS II-2/10.2.2.2
Each main fire pumpAt least 80% of total required capacity divided by number of pumps, not less than 25 m³/hSOLAS II-2/10.2.2.4.2
Emergency fire pumpAt least 40% of total fire pump capacity; not less than 25 m³/h (cargo ships 2,000 GT and over) or 15 m³/h (under 2,000 GT)FSS Code Ch. 12
Fire main pressure at hydrants, cargo ships0.27 N/mm² (6,000 GT and over); 0.25 N/mm² (under 6,000 GT)SOLAS II-2/10.2.1.6
Fire main pressure, passenger ships0.40 N/mm² (4,000 GT and over); 0.30 N/mm² (under 4,000 GT)SOLAS II-2/10.2.1.6
Hydrant coverageTwo jets, not from the same hydrant, one from a single length of hose, to reach any normally accessible partSOLAS II-2/10.2.1.5.1
Fire hose lengthAt least 10 m; not more than 15 m in machinery spaces, 20 m in other spaces and open decks, 25 m on open decks of ships over 30 m breadthSOLAS II-2/10.2.3.1.1
Nozzle sizesStandard 12, 16 and 19 mm; accommodation and service spaces need not exceed 12 mmSOLAS II-2/10.2.3.3
International shore connectionShips of 500 GT and over; flange outside diameter 178 mm, inside 64 mm, bolt circle 132 mm, four 19 mm slots, four 16 mm boltsFSS Code Ch. 2
Portable extinguishersPowder or CO2 at least 5 kg, foam at least 9 l, mass not over 23 kg; ships 1,000 GT and over carry at least five in accommodation, service spaces and control stationsFSS Code Ch. 4; SOLAS II-2/10.3.2.1
Spare charges100% of the first ten extinguishers and 50% of the rest; not more than 60 in totalSOLAS II-2/10.3.3.1
Fire-fighter's outfitsAt least two on every ship; two more on tankersSOLAS II-2/10.10.2
Fire party radiosAt least two two-way portable radiotelephones per fire party, explosion-proof or intrinsically safeSOLAS II-2/10.10.4
Breathing apparatusAt least 1,200 l of air or 30 min; fireproof lifeline at least 30 m; two spare charges each (one if cylinders can be recharged on board); low-air audible alarm before 200 l remainFSS Code Ch. 3; SOLAS II-2/10.10.2.5
Safety lampApproved type, at least 3 h burning; explosion-proof on tankersFSS Code Ch. 3
EEBDService duration at least 10 min; for escape onlyFSS Code Ch. 3
CO2, machinery spacesLarger of 40% of gross volume (excluding casing above the 40% area level) or 35% including casing; 85% of gas in 2 minFSS Code Ch. 5
CO2, cargo spaces30% of gross volume of largest cargo space; two-thirds of the gas within 10 min for container and general cargo spaces, 20 min for solid bulk (ships built from 1 July 2012)FSS Code Ch. 5
CO2 free gas volume0.56 m³/kgFSS Code Ch. 5
Pre-discharge alarmLong enough to evacuate, never less than 20 sFSS Code Ch. 5
Tanker deck foamGreatest of 0.6 l/min/m² of cargo deck area, 6 l/min/m² of largest tank area, or 3 l/min/m² of largest monitor area (not less than 1,250 l/min); 20 min of foam with inert gas, 30 min withoutFSS Code Ch. 14
Inert gasSupply at not more than 5% oxygen; tanks kept at not more than 8% oxygen and positive pressureFSS Code Ch. 15; SOLAS II-2/4.5.5
Fire detectorsSmoke: operate before 12.5% obscuration per metre, not below 2%; heat: 54–78°C at under 1°C/min riseFSS Code Ch. 9

How often must fire-fighting equipment be tested and inspected?

SOLAS Reg. II-2/14 requires an onboard maintenance plan; IMO guidance MSC.1/Circ.1432 gives the minimum weekly to ten-yearly checks[1]. Fixed CO2 systems follow MSC.1/Circ.1318/Rev.1[2] and portable extinguishers follow A.951(23)[3]. Chief mate candidates should be able to recite this table.

Key maintenance intervals (MSC.1/Circ.1432, Circ.1318/Rev.1, A.951(23))
IntervalMain items
WeeklyLamp test on fire detection and fixed system panels; control valves in correct position; public address and general alarm working; BA and EEBD cylinder gauges in range; low-location lighting check; water mist and sprinkler panel alarms and pump unit
MonthlyAll hydrants, hoses and nozzles in place; run all fire pumps for pressure; emergency fire pump fuel; fireman's outfit lockers complete; fixed gas cylinder gauges; sprinkler pressure tank levels and automatic pump start; test a sample of detectors and call points so all are tested within five years; CO2 system visual check every 30 days
QuarterlyInternational shore connection serviceable; foam concentrate quantity; fire dampers local operation; fire doors in main vertical zone bulkheads (passenger ships)
AnnualFlow test all fire pumps; test emergency fire pump with isolation valves closed; test all hydrant valves; pressure test a sample of hoses so all are tested within five years; test detection systems and emergency power switchover; fixed gas system alarms and fuel shut-offs; foam concentrate samples sent for testing (first test of most foams after three years); fire dampers remote operation; galley ducts free of grease; BA masks, demand valves and air quality; portable extinguishers serviced
Two-yearlyFixed gas cylinders weighed: above 95% of nominal charge under Circ.1432; for CO2, above 90% under Circ.1318/Rev.1 (in cargo ships at each intermediate, periodical or renewal survey); blow through discharge piping and nozzles
Five-yearlyInternal inspection of control valves; foam proportioner accuracy (+30% to −10%); flush high-expansion foam piping; hydrostatic test of steel BA cylinders; low-location lighting luminance; one portable extinguisher of each type and year test-discharged
Ten-yearlyHydrostatic test and internal check of 10% of fixed gas cylinders (50% if one fails, then all); flexible hoses replaced (not more than 10 years); portable extinguishers hydraulically tested; all CO2 cylinders tested before the 20-year anniversary

How should you structure a fire-fighting answer?

Answer situational fire questions in the order you would act, out loud, and name the rule only after the action. Examiners mark the sequence first and the numbers second.

  1. Raise the alarm: general alarm or fire alarm, inform the master and engine room, announce location on the public address.
  2. Locate and assess: what is burning, where, are people inside, what is next to it (fuel tanks, dangerous goods, cargo).
  3. Contain: close doors, fire dampers and ventilation, stop fans and fuel pumps (remote stops), isolate electrical supply.
  4. Muster and account for everyone: headcount at muster stations before any fixed gas release.
  5. Attack: first-aid with portable extinguisher if small and safe; otherwise fire party in BA with charged hoses; fixed system if the space must be sealed.
  6. Boundary cool all six sides and keep checking adjacent spaces.
  7. Ship handling and communications: put the fire downwind (wind on the opposite side), reduce speed, consider urgency or distress message, inform company.
  8. After the fire: re-flash watch, ventilate carefully, gas-test before entry, pump out fire-fighting water and check stability, record in the log book.

This order is the core of how to answer oral exam questions. Practise saying it aloud with our mock oral drill.

  1. 1
    Alarm

    Sound the fire alarm, inform the master and engine room, give the location on the public address.

  2. 2
    Assess

    Find out what is burning, whether anyone is missing and what hazards are next to the fire.

  3. 3
    Contain

    Close doors, dampers and ventilation; stop fans and fuel pumps; isolate power.

  4. 4
    Account for people

    Muster and do a headcount before any fixed gas release.

  5. 5
    Attack

    Use portable extinguishers if safe, then hose teams in breathing apparatus, then a fixed system if needed.

  6. 6
    Boundary cool

    Cool all six sides of the space and watch the next compartments for heat.

  7. 7
    Handle the ship

    Put the fire on the lee side, reduce speed, send urgency or distress messages if needed.

  8. 8
    Recover

    Keep a re-flash watch, ventilate and gas-test before entry, pump out water, check stability and record everything.

How often are fire drills held and what must they include?

On a cargo ship every crew member must take part in at least one fire drill and one abandon ship drill every month (SOLAS Reg. III/19.3.2). If more than 25% of the crew have not taken part in a drill on that ship in the previous month, both drills must be held within 24 hours of leaving port.

A fire drill must, as far as practicable, be planned as if a real emergency happened in different parts of the ship. Under SOLAS III/19 it includes reporting to stations and preparing for duties on the muster list, starting a fire pump with at least two jets of water to show the system works, checking fireman's outfits and other personal rescue equipment, checking relevant communication equipment, checking watertight doors, fire doors, fire dampers and main inlets and outlets of ventilation, and checking the arrangements for later abandoning ship.

Enclosed space entry and rescue drills are held at least every two months[5]; see our enclosed space entry page. Officers need STCW basic training (Reg. VI/1) and advanced fire fighting (Reg. VI/3), with proof of maintained standards every five years. Linked topics: life-saving appliances and ISM Code drill records.

What changed in fire safety rules in 2024–2026?

The big date is 1 January 2026. A package of SOLAS Chapter II-2 and FSS Code amendments came into force then[4]. Examiners now like to ask about these because they test whether you keep up.

  • PFOS foam ban: foams containing PFOS may not be used or stored[4]. Existing ships must comply by the first survey on or after 1 January 2026[6]. Know how to check: the foam data sheet or a certificate from the supplier.
  • Oil fuel flashpoint: the 60°C minimum flashpoint already existed in Reg. II-2/4; the new text adds a supplier declaration of flashpoint before bunkering[7].
  • Ro-ro and vehicle spaces: new detection, video monitoring and fixed water-based systems on weather decks. These apply to ships constructed on or after 1 January 2026; existing passenger ships with these spaces must add the new detection and video monitoring by their first survey on or after 1 January 2028[8].
  • Cargo ship fire detection: changes to detection and alarm in control stations and cargo control rooms[4].

For life-saving appliance changes in the same period, see life-saving appliances.

What mistakes make candidates fail fire-fighting questions?

Most fails on this topic come from a wrong sequence, not from a missing number. The examiner hears that you would send people into danger or release gas before checking the space is clear.

  • Releasing CO2 before a headcount. Always muster and account for everyone first, then close the space, then release.
  • Forgetting to stop ventilation and fuel. A fire with fans running and fuel pumps feeding it will not go out.
  • Opening the space too early after CO2. Wait for it to cool; re-entry is a planned operation with BA and charged hoses.
  • Ignoring stability. Tonnes of fire-fighting water high in the ship cause free surface effect and list. Mention pumping out and checking GM. See ship stability.
  • Using water on oil or live electrics. Say spray or fog, not jet, and isolate power.
  • Saying EEBD for fire-fighting. An EEBD is for escape only.
  • Mixing up guidance numbers. For CO2 cylinders the content check is above 90% (Circ.1318/Rev.1); the 95% figure in Circ.1432 is for other fixed gas systems.
  • No communication with the bridge or master. Each answer should include who you inform.

Our article on why seafarers fail oral exams covers more patterns.

Which fire scenarios should you rehearse?

Rehearse at least these six scenarios aloud, timing yourself to about two minutes each. Examiners often change one detail (night, port, heavy weather, missing person) to see if you adapt.

Scenario First three actions Key risk the examiner waits for
Engine room fire, ship at sea Alarm, stop ventilation and fuel via remote stops, muster and headcount Releasing CO2 with people inside; loss of propulsion near land
Galley deep fat fryer fire Isolate power, use fixed galley system or fire blanket, close hood damper Water on burning oil causes an explosion of steam and oil
Cabin fire in accommodation at night Alarm, search and rescue with BA team, close doors and fire dampers Smoke spread through stairways; missing crew
Container hold fire Close hatches and ventilation, CO2 per FSS Code, boundary cool Dangerous goods: check the IMDG manifest and EmS before choosing water or gas
Tanker deck fire at manifold Stop cargo, close valves, foam monitors, emergency shutdown Inert gas pressure and oxygen; fire spreading to vents (see tanker operations)
Fire in port Alarm, call shore fire brigade, hand over fire control plan and crew list International shore connection, cargo plan, stability as water builds up

After each scenario, the examiner may ask for the log entries and reports; see ISM Code non-conformity reporting.

How do you calculate CO2 quantity, spare charges and emergency fire pump capacity?

Use the FSS Code and SOLAS II-2 percentages: CO2 for a machinery space is the larger of 40% of the gross volume without the casing or 35% with it, at 0.56 m³ of free gas per kg[9]. The worked examples below use example volumes; your ship's figures are in its fire control plan.

Worked example 1: engine room CO2. Gross volume of the engine room without the upper casing: 6,000 m³. With the casing: 7,500 m³.

  • 40% × 6,000 = 2,400 m³ of free gas.
  • 35% × 7,500 = 2,625 m³ of free gas.
  • Take the larger: 2,625 m³.
  • Mass of CO2: 2,625 ÷ 0.56 = 4,687.5 kg.
  • With 45 kg cylinders (a common size; check your ship): 4,687.5 ÷ 45 = 104.2, so 105 cylinders.
  • Discharge: 85% within 2 minutes, so 0.85 × 4,687.5 = about 3,984 kg in the first 2 minutes.

Worked example 2: cargo hold CO2. Largest cargo hold: 12,000 m³.

  • 30% × 12,000 = 3,600 m³ of free gas.
  • 3,600 ÷ 0.56 = 6,428.6 kg, or 143 cylinders of 45 kg (6,428.6 ÷ 45 = 142.9).
  • In a container or general cargo space, two-thirds of the gas within 10 minutes: about 4,286 kg.

Worked example 3: spare charges (SOLAS II-2/10.3.3.1). Spare charges are 100% for the first ten extinguishers and 50% for the rest, with no more than 60 in total. The table shows three ships. For extinguishers that cannot be recharged on board, extra extinguishers are carried instead.

Worked example 4: emergency fire pump. It must deliver at least 40% of the total capacity of the main fire pumps, and never less than 25 m³/h on cargo ships of 2,000 GT and above[10]. If the main pumps must deliver 150 m³/h in total, the emergency pump needs 0.40 × 150 = 60 m³/h. If they must deliver 50 m³/h, 40% is 20 m³/h, so the 25 m³/h minimum applies.

Recompute each line aloud in the oral. Examiners care less about the final figure than about whether you pick the larger of the two machinery space figures and know the 0.56 factor. Practise these with the fire-fighting and LSA MCQ bank and the engine room fire systems topic.

Spare charges for portable extinguishers (SOLAS II-2/10.3.3.1)
Extinguishers on boardFirst ten (100%)Remainder (50%)Spare charges
8808
261016 × 50% = 818
15010140 × 50% = 7080, capped at 60

How do you walk through a fire scenario in the oral?

Answer in five steps: Situation, Assessment, Rule, Action, Report. Act first, then name the rule. These three walk-throughs are the ones examiners build their follow-ups on.

1. You are OOW at 0300. A smoke detector alarms in the accommodation.

  • Situation: The bridge panel shows zone 4, deck C, port side cabins.
  • Assessment: It may be a real fire or a false alarm. People are asleep in that zone.
  • Rule: SOLAS II-2/7 (detection) and the muster list under SOLAS III/8 and III/37. STCW A-VIII/2: call the master in any emergency.
  • Action: Call the master and send the lookout or a rating to check, without opening a hot door. If fire is confirmed, sound the fire alarm, announce the location, stop accommodation ventilation and close fire doors. Keep the ship safe: reduce speed and turn so the wind takes smoke away from the accommodation.
  • Report: Headcount at muster. Log the times, the zone and every action.

Examiner's note: The panel listens for "check before opening the door" and "headcount". The follow-up: "The headcount shows the third engineer missing. What now?" Search and rescue team in breathing apparatus, with a charged hose and a lifeline.

2. You are chief mate. Smoke is coming from a container hold with dangerous goods aboard.

  • Situation: Bay 14 below deck. The DG manifest shows class 3 and class 9 lithium batteries in that bay.
  • Assessment: The burning unit and its contents decide the medium. Water may be wrong for some classes.
  • Rule: SOLAS II-2/10.7 (fixed systems for cargo spaces), FSS Code Ch. 5 (CO2), IMDG Code EmS Guide and MFAG; SOLAS II-2/19 for dangerous goods.
  • Action: Close hatches and hold ventilation. Muster and confirm nobody is in the hold. Read the EmS fire schedules for the UN numbers. With the master's decision, release CO2 into the hold. Boundary cool the hatch covers and the next bays.
  • Report: The master informs the company and the nearest coastal State, and prepares for a port of refuge. Log the gas release time and the quantity.

Examiner's note: Strong candidates say "EmS for the UN number" before choosing the medium. Follow-up: "How long do you keep the hold closed after CO2?"

3. You are master. The engine room fire is out of control and one oiler is missing.

  • Situation: Hose teams were pulled out. The chief engineer wants CO2 now.
  • Assessment: Releasing gas with a person inside may kill him; waiting may lose the ship.
  • Rule: FSS Code Ch. 5 (pre-discharge alarm, two separate controls) and SOLAS II-2/5.2 (remote stops and closing openings).
  • Action: Order an urgent search of the escape routes and the emergency escape trunk by a BA team, if safe. Stop ventilation, fuel pumps and fans by remote stops; close skylights and dampers. Release CO2 only when the person is found, or when you decide the ship and the rest of the crew are at greater risk.
  • Report: Send an urgency or distress message if propulsion is lost near danger. Inform the company. Log the decision and the reasons.

Examiner's note: The panel does not want a quick "release" or a flat "never release". It wants the decision, the reasons and the log entry. Follow-up: "When do you re-enter?"

What do weak and strong fire-fighting answers sound like?

Weak fire answers name equipment. Strong answers give the order of actions and the rule. These four questions are where candidates fumble most.

Examiner's note: Weak answer: "I would use the EEBD to go in and rescue him." Strong answer: "An EEBD is for escape only and lasts at least 10 minutes (FSS Code Ch. 3). Rescue is done by a team in full breathing apparatus with a lifeline and a charged hose." The weak one puts a second person at risk.

Examiner's note: Weak answer: "Close the engine room and release CO2." Strong answer: "Stop fans and fuel pumps, close openings, muster and do a headcount, then release on the master's order after the pre-discharge alarm." The weak one skips the headcount.

Examiner's note: Weak answer: "Class C fires are electrical." Strong answer: "It depends on the standard. Under ISO and EN, C is gases and electrical fire is a hazard, not a class. Under the US NFPA system, C is energised electrical equipment." The weak answer is right only in one system and the candidate does not know which.

Examiner's note: Weak answer: "CO2 cylinders are refilled below 95%." Strong answer: "For CO2, MSC.1/Circ.1318/Rev.1 says refill below 90% of the charge; the 95% figure in MSC.1/Circ.1432 is for other fixed gas systems." The weak answer uses the wrong circular[2].

What should you read to revise fire-fighting?

Read the rule texts first, then one practical book. Examiners expect you to quote the regulation, not a training handout.

  • SOLAS Consolidated Edition, Chapter II-2 (IMO publication) and Chapter III Reg. 19 for drills.
  • FSS Code (International Code for Fire Safety Systems), IMO publication.
  • MSC.1/Circ.1432, MSC.1/Circ.1318/Rev.1 and resolution A.951(23) for maintenance.
  • STCW Code Tables A-VI/1-2 and A-VI/3 for the fire-fighting competences.
  • Your ship's fire control plan, fire safety operational booklet (SOLAS II-2/16) and training manual (SOLAS II-2/15).
  • A standard textbook such as Ship Fire Fighting titles used on STCW advanced fire-fighting courses, and your company safety management system manual.

See our list of books for second mate orals, test yourself with the fire-fighting and LSA MCQ bank and the SOLAS MCQ bank, then book a mock with early access to our AI voice examiner. The 30-day oral preparation plan shows where to fit this topic.

Oral practice

38 oral questions with model answers

Read the question, answer it out loud as if the examiner is across the table, then open the model answer and mark yourself honestly.

–0/38 done
  1. 1
    CoreFSS Code; SOLAS Ch. II-2 Reg. 10

    Explain the fire triangle and the fire tetrahedron. How does each extinguishing method attack them?

    Model answer points
    • Fire needs fuel, heat and oxygen (triangle); the tetrahedron adds the self-sustaining chemical chain reaction.
    • Starving removes fuel: close fuel valves, use quick-closing valves, move combustibles.
    • Smothering removes oxygen: CO2, foam, fire blanket, closing doors and ventilation.
    • Cooling removes heat: water jet, spray or fog; also boundary cooling.
    • Chain-breaking stops the reaction: dry powder and some clean agents.
    • Most fires are fought with two methods together, for example foam (smothering plus cooling).
    The examiner may follow up with
    • Which method does dry powder use?
    • Why can a fire re-ignite after dry powder?
    How did you do?
  2. 2
    CoreSOLAS Ch. II-2 Reg. 4

    Define flash point, fire point and auto-ignition temperature. What is the minimum flash point for marine fuel oil?

    Model answer points
    • Flash point: lowest temperature at which a liquid gives off enough vapour to form a mixture that flashes when a flame is applied, but does not keep burning.
    • Fire point: slightly higher; the vapour keeps burning after ignition.
    • Auto-ignition temperature: the vapour ignites by itself with no flame or spark (for example on a hot exhaust).
    • SOLAS II-2/4.2.1 sets 60°C as the general minimum flash point for oil fuel (emergency generator fuel may be lower as permitted).
    • Since 1 January 2026 the supplier must declare the flash point before bunkering (MSC.520(106)).
    The examiner may follow up with
    • Why are hot surfaces in the engine room insulated?
    • What is the flammable range of a vapour?
    How did you do?
  3. 3
    CoreFSS Code Ch. 4; resolution A.951(23)

    What are the classes of fire and which extinguisher do you use on each?

    Model answer points
    • State the standard first: under ISO 3941 / EN 2: A solids, B flammable liquids, C gases, D metals, F cooking oils and fats.
    • A: water or foam. B: foam, dry powder, CO2. C: isolate the gas supply first; dry powder. D: special metal-fire powder. F: wet chemical or fixed galley system.
    • Electrical fire is not a separate class under ISO; isolate power, then use CO2 or dry powder.
    • Under the US NFPA system, class C means energised electrical equipment, so say which system you mean.
    • On board, extinguishers are colour-coded or labelled by agent; read the label before use.
    The examiner may follow up with
    • Why not water on a class B fire?
    • What would you use on an electrical fire in the bridge console?
    How did you do?
  4. 4
    CoreSOLAS Ch. II-2 Reg. 7; STCW Code A-VIII/2

    You are OOW at 0200 and the fire detection panel on the bridge shows a fire in the engine room. What do you do?

    Model answer points
    • Acknowledge the alarm, note the zone and time, and call the duty engineer and the master at once.
    • If confirmed or no answer from the engine room, sound the fire alarm and announce the location on the public address.
    • Keep the navigational watch: check traffic, keep a lookout, be ready for loss of propulsion or power; consider safe water and anchoring options.
    • Prepare for the master to decide on ventilation shut-down, fuel stops and fixed system; muster the crew and get a headcount.
    • Put the wind on the side away from the fire if you have steering; reduce speed if safe.
    • Record the times and actions in the log book; prepare an urgency or distress message if the master orders it.
    The examiner may follow up with
    • What if the detector shows a fault rather than a fire?
    • Who leads the attack party?
    How did you do?
  5. 5
    CoreSOLAS Ch. II-2 Reg. 10; SOLAS Ch. II-2 Reg. 15

    List the fire-fighting equipment carried on your last ship and where it is kept.

    Model answer points
    • Fire main: fire pumps (at least two on a cargo ship of 1,000 GT and over), emergency fire pump outside the machinery space, hydrants, hoses and nozzles.
    • Portable and wheeled extinguishers in accommodation, machinery spaces and control stations; at least five in accommodation, service spaces and control stations on ships of 1,000 GT and over.
    • Fixed systems: CO2 or other gas for machinery spaces and holds, local water mist in machinery spaces where required, galley hood system, deck foam on tankers.
    • Fire-fighter's outfits: at least two (two more on tankers), BA with spare cylinders, EEBDs.
    • Fire detection and alarm, manual call points, fire doors and dampers, international shore connection.
    • All shown on the fire control plan, with a copy in a weathertight case outside the deckhouse.
    The examiner may follow up with
    • Where is the CO2 room and who has the key?
    • What is shown on a fire control plan?
    How did you do?
  6. 6
    CoreFSS Code Ch. 3; SOLAS Ch. II-2 Reg. 10.10

    What is in a fire-fighter's outfit?

    Model answer points
    • Personal equipment: protective clothing (outer surface water-resistant), boots of rubber or non-conducting material, rigid helmet, approved electric safety lamp with at least 3 hours burning (explosion-proof on tankers), axe with insulated handle.
    • Breathing apparatus: self-contained compressed air with at least 1,200 litres of air, or another type working for at least 30 minutes; cylinders interchangeable.
    • Fireproof lifeline at least 30 m long, with snap-hook to the harness.
    • BA has an audible alarm and a visual or other device that warns the user before the air left falls to 200 litres (FSS Code Ch. 3; ships built from 1 July 2014).
    • At least two two-way portable radiotelephones for each fire party, explosion-proof or intrinsically safe (SOLAS II-2/10.10.4).
    • Two spare charges per BA (one if the ship can fully recharge cylinders on board).
    • Every ship carries at least two outfits; tankers carry two more.
    The examiner may follow up with
    • How do you check a BA before use?
    • What is the whistle warning on a BA set?
    How did you do?
  7. 7
    CoreSOLAS Ch. II-2 Reg. 13.3.4 and 13.4.3; FSS Code Ch. 3

    What is an EEBD and how many must be carried?

    Model answer points
    • Emergency escape breathing device: a supplied-air or oxygen device used only to escape from a hazardous atmosphere.
    • Service duration at least 10 minutes, with a hood or full face piece; can be carried hands-free.
    • Not for fire-fighting, entering oxygen-deficient tanks or rescue work.
    • Cargo ships carry EEBDs in accommodation (at least two) and in machinery spaces at positions on escape routes as approved; spares and training units as required.
    • Weekly check of cylinder gauge (MSC.1/Circ.1432); annual check per maker's instructions.
    The examiner may follow up with
    • Can you use an EEBD to rescue a collapsed person in a tank?
    • Where would you expect to find EEBDs in the engine room?
    How did you do?
  8. 8
    CoreSOLAS Ch. II-2 Reg. 10.2.3

    Give the requirements for fire hoses and nozzles.

    Model answer points
    • Hoses of non-perishable approved material, length at least 10 m, not more than 15 m in machinery spaces, 20 m in other spaces and open decks, 25 m on open decks of ships over 30 m breadth.
    • Each hose with a nozzle and couplings, kept at the hydrant ready for use.
    • Standard nozzle sizes 12, 16 and 19 mm; accommodation and service spaces need not exceed 12 mm; machinery spaces and exterior positions sized for maximum discharge from two jets, not over 19 mm.
    • Dual-purpose (spray and jet) nozzles with shut-off.
    • Annual pressure test of a sample so all hoses are tested within five years (MSC.1/Circ.1432).
    The examiner may follow up with
    • Why is the machinery space hose shorter?
    • What pressure must be at the hydrant?
    How did you do?
  9. 9
    CoreSOLAS Ch. II-2 Reg. 10.2.1.7; FSS Code Ch. 2

    What is the international shore connection and when do you use it?

    Model answer points
    • Required on ships of 500 GT and over (SOLAS II-2/10.2.1.7): a standard flange that lets the ship's fire main be connected to shore water or another ship, whatever the hose couplings.
    • Dimensions: outside diameter 178 mm, inside 64 mm, bolt circle 132 mm, four 19 mm slots, flange at least 14.5 mm thick, four 16 mm bolts 50 mm long.
    • Kept on board with gasket, bolts and nuts, ready for use on either side of the ship.
    • Used in port when the ship's pumps are not available, for example during a dead-ship dry dock or engine room fire.
    • Checked quarterly under MSC.1/Circ.1432.
    The examiner may follow up with
    • Where is it stowed on your ship?
    • Why must it fit both sides?
    How did you do?
  10. 10
    CoreSOLAS Ch. II-2 Reg. 10.3; FSS Code Ch. 4; resolution A.951(23)

    What are the rules for portable fire extinguishers and spare charges?

    Model answer points
    • Powder or CO2 extinguishers at least 5 kg, foam at least 9 litres; total mass not over 23 kg (FSS Code Ch. 4).
    • Ships of 1,000 GT and over carry at least five in accommodation, service spaces and control stations; one stowed near the entrance of each space.
    • No CO2 extinguishers in accommodation spaces.
    • Spare charges for 100% of the first ten and 50% of the rest, not more than 60 in total; if they cannot be recharged on board, carry extra extinguishers instead.
    • A.951(23): serviced at intervals not exceeding one year, one of each type and year test-discharged every five years, hydraulic test at intervals not exceeding ten years.
    The examiner may follow up with
    • How do you know an extinguisher has been used?
    • What extinguisher goes outside the paint locker?
    How did you do?
  11. 11
    CoreSOLAS Ch. III Reg. 19.3; SOLAS Ch. II-2 Reg. 15

    How often are fire drills held on a cargo ship, and what must a fire drill include?

    Model answer points
    • Every crew member takes part in at least one fire drill a month; if more than 25% of crew have not done a drill on that ship in the last month, drills within 24 hours of leaving port.
    • Plan it as a realistic emergency in different parts of the ship.
    • Report to stations per the muster list; start a fire pump and show at least two jets of water.
    • Check fireman's outfits, personal rescue equipment and communication equipment.
    • Check watertight doors, fire doors, fire dampers and main ventilation inlets and outlets; check arrangements for abandoning ship.
    • Record in the log book; debrief and update training needs.
    The examiner may follow up with
    • What is a debrief for?
    • How do you train a new joiner who missed the drill?
    How did you do?
  12. 12
    CoreSOLAS Ch. II-2 Reg. 15.2.4

    What is a fire control plan and where are copies kept?

    Model answer points
    • General arrangement plans for each deck showing control stations, fire sections (A and B class divisions), fire detection and alarm, sprinklers, extinguishing appliances, means of access, ventilation with fan controls and dampers, and the international shore connection.
    • Kept up to date; displayed permanently for the officers' guidance.
    • A duplicate set kept in a prominently marked weathertight enclosure outside the deckhouse for shore fire-fighters.
    • Descriptions in the language required by the flag; if that is not English or French, a translation into one of them is included.
    • Supported by the fire training manual and the fire safety operational booklet.
    The examiner may follow up with
    • Who would you hand the plan to in port?
    • What symbols are used?
    How did you do?
  13. 13
    CoreSOLAS Ch. II-2 Reg. 7; FSS Code Ch. 9

    What types of fire detector are fitted on your ship, where, and at what settings do they operate?

    Model answer points
    • Smoke detectors in accommodation stairways, corridors and escape routes (cargo ships, SOLAS II-2/7.5); they must operate before smoke density exceeds 12.5% obscuration per metre, but not below 2% per metre (FSS Code Ch. 9).
    • Heat detectors where smoke detection would give false alarms (galley, laundry, drying rooms): operate between 54°C and 78°C when the rise is under 1°C per minute; higher settings allowed in galleys and drying rooms.
    • Flame detectors in machinery spaces near hazards such as purifiers and boilers, as approved.
    • Manual call points at exits and in corridors; detectors grouped in sections shown on the panel on the bridge or fire control station.
    • System powered from the main and emergency sources, with fault alarms as well as fire alarms.
    • Test as per MSC.1/Circ.1432: weekly panel check, monthly sample of detectors so all are tested within five years.
    The examiner may follow up with
    • Why are heat detectors used in the galley instead of smoke detectors?
    • What do you do when the panel shows a fault rather than a fire?
    How did you do?
  14. 14
    DeeperFSS Code Ch. 5; SOLAS Ch. II-2 Reg. 10.4

    Walk me through releasing CO2 into the engine room.

    Model answer points
    • Master's decision, usually when the fire cannot be controlled by hoses and portables.
    • Stop main and auxiliary engines if the master agrees, stop all ventilation fans, close fire dampers, skylights, doors, stop fuel pumps and close quick-closing valves remotely.
    • Muster and headcount: confirm nobody is in the space.
    • Open the release cabinet (pre-discharge alarm sounds, at least 20 seconds before discharge), open the main valve, then release the cylinders as per the instructions.
    • System must deliver 85% of the gas in 2 minutes.
    • Boundary cool, keep the space closed, monitor temperatures; do not re-open until cooled, then enter with BA team and charged hoses.
    The examiner may follow up with
    • How long would you keep it closed?
    • What would you do if one crew member is missing?
    How did you do?
  15. 15
    DeeperFSS Code Ch. 5 para 2.2

    How is the quantity of CO2 required for machinery spaces and cargo holds calculated?

    Model answer points
    • Cargo spaces: free gas at least 30% of the gross volume of the largest cargo space protected.
    • Machinery spaces: the larger of 40% of gross volume (excluding casing above the level where its area is 40% or less of the space) or 35% including the casing.
    • For cargo ships under 2,000 GT these become 35% and 30%.
    • Free gas volume calculated at 0.56 m³/kg.
    • Machinery spaces: 85% of the gas discharged within 2 minutes. Container and general cargo spaces: at least two-thirds within 10 minutes; solid bulk cargo spaces: two-thirds within 20 minutes (ships built from 1 July 2012).
    • One supply can protect several spaces; size it for the largest.
    The examiner may follow up with
    • Why is the machinery space discharge so fast?
    • Why do you release CO2 into a cargo hold more slowly?
    How did you do?
  16. 16
    DeeperSOLAS Ch. II-2 Reg. 10.7 and Reg. 19; IMDG Code; FSS Code Ch. 5

    A container in a hold is on fire. What do you do?

    Model answer points
    • Alarm, master informed, find bay and stack from detection and smoke; muster and headcount.
    • Close hatch covers, ventilation and openings; stop fans.
    • Check the dangerous goods manifest and stowage plan; read the EmS guide for the cargo next to the fire (some cargoes react with water, others are not stopped by CO2).
    • Release CO2 into the hold per the system instructions; keep the hold sealed.
    • Boundary cool hatch covers and adjacent bulkheads; watch stacks on deck above.
    • Report to company and coastal state, consider port of refuge; check stability as water collects.
    The examiner may follow up with
    • Why might water be the wrong choice for some cargoes?
    • What is the EmS guide?
    How did you do?
  17. 17
    DeeperSOLAS Ch. II-2 Reg. 10.6.4; MSC.1/Circ.1432

    There is a fire in the galley deep fat fryer. What do you do and what must you not do?

    Model answer points
    • Never use water: it turns to steam and throws burning oil out (a fireball).
    • Isolate power or gas to the fryer and stop the extraction fan; close the hood damper.
    • Use the fixed galley fire-extinguishing system if fitted, or a fire blanket, or a wet chemical extinguisher.
    • Raise the alarm; boundary cool if spreading into the ducting.
    • Keep checking the galley exhaust duct — grease fires often travel inside it.
    • Prevention: clean filters and ducts; MSC.1/Circ.1432 annual check that galley ducts are free of grease.
    The examiner may follow up with
    • Why does a CO2 extinguisher not work well on a fryer?
    • What class of fire is cooking oil?
    How did you do?
  18. 18
    DeeperSOLAS Ch. II-2 Reg. 15; SOLAS Ch. III Reg. 19; STCW Reg. VI/3

    A cabin is on fire at night and a crew member is missing. As chief mate, how do you organise the response?

    Model answer points
    • Alarm and muster; headcount confirms the missing person; inform master.
    • Send a search and rescue team in BA with lifeline and charged hose, working in pairs; brief them on the cabin location and escape routes.
    • Close fire doors, stop ventilation in that zone, close fire dampers to stop smoke spread.
    • Attack team with spray to cool and protect the rescue team; boundary cooling team on decks above and below.
    • Set up a BA control point with entry times and air pressure log.
    • First aid and medical advice ready; record all times.
    The examiner may follow up with
    • How do you calculate a BA wearer's turn-around time?
    • How do you communicate with the team inside?
    How did you do?
  19. 19
    DeeperSOLAS Ch. II-2 Reg. 3; FTP Code

    What are A, B and C class divisions?

    Model answer points
    • A class: steel or equivalent, stiffened, prevents passage of smoke and flame to the end of the one-hour standard fire test; insulated so the unexposed side's average temperature does not rise more than 140°C and no point more than 180°C within the rated time (A-60, A-30, A-15, A-0).
    • B class: approved non-combustible material, prevents passage of flame to the end of the first half hour; temperature limits 140°C average and 225°C at any point within the rating (B-15, B-0).
    • C class: approved non-combustible material, no smoke or temperature limits.
    • Used to divide the ship into fire zones and to protect escape routes and control stations.
    The examiner may follow up with
    • Where do you find A-60 on a cargo ship?
    • Why must penetrations keep the rating?
    How did you do?
  20. 20
    DeeperMSC.1/Circ.1432; SOLAS Ch. II-2 Reg. 14

    What does MSC.1/Circ.1432 require you to check weekly and monthly on the fire-fighting systems?

    Model answer points
    • Weekly: lamp test on fire detection and fixed system panels; control and section valves in the right position; public address and general alarm working; BA and EEBD cylinder gauges in range; low-location lighting; water mist and sprinkler alarms and pump unit.
    • Monthly: all hydrants, hoses and nozzles in place and serviceable; run all fire pumps for pressure; emergency fire pump fuel and heating; fireman's outfit lockers complete; fixed gas cylinder gauges; sprinkler tank levels and auto-start; foam system valves.
    • Monthly sample of detectors and manual call points so that all are tested within five years.
    • Records kept on board (paper or computer).
    • Some tasks need trained service technicians; the maintenance plan says which.
    The examiner may follow up with
    • What is checked quarterly?
    • Who signs the maintenance records?
    How did you do?
  21. 21
    DeeperMSC.1/Circ.1432 para 7.1

    What annual tests do you carry out on the fire main and pumps?

    Model answer points
    • Visually inspect accessible components.
    • Flow test all fire pumps for pressure and capacity.
    • Test the emergency fire pump with the isolating valves closed, so it proves it can supply the main on its own.
    • Test all hydrant valves; check relief valves are set; clean filters and strainers; check nozzle types are correct.
    • Pressure test a sample of hoses at maximum fire main pressure so that all hoses are tested within five years.
    • Record results in the planned maintenance system.
    The examiner may follow up with
    • Why close the isolating valve during the emergency pump test?
    • What pressure would you expect at the furthest hydrant?
    How did you do?
  22. 22
    DeeperMSC.1/Circ.1318/Rev.1

    What maintenance does a fixed CO2 system need?

    Model answer points
    • Monthly (every 30 days): stop valves closed, release controls in position and accessible, piping intact, cylinders secured, alarms not damaged; low-pressure tanks: gauge and level.
    • Annual: check boundaries for new openings, cylinders for damage or corrosion, piping and nozzles, hoses tight, warning signs and release instructions.
    • Two-yearly (cargo ships: at each intermediate, periodical or renewal survey): weigh cylinders — refill if below 90% of nominal charge; blow through piping with dry air or nitrogen; specialists test the release heads and time delay.
    • Five-yearly: internal inspection of control valves.
    • Ten-yearly: hydrostatic test of at least 10% of cylinders (50% if one fails, then all); all cylinders tested before the 20-year anniversary; flexible hoses replaced at not more than 10 years.
    The examiner may follow up with
    • What safety precautions apply when working in the CO2 room?
    • How do you check the contents of a low-pressure tank?
    How did you do?
  23. 23
    DeeperFSS Code Ch. 14; SOLAS Ch. II-2 Reg. 10.8

    Describe the deck foam system on an oil tanker.

    Model answer points
    • Fixed low-expansion foam from monitors and applicators covering the cargo tank deck.
    • Foam solution rate: the greatest of 0.6 l/min/m² of cargo tank deck area, 6 l/min/m² of the largest single tank area, or 3 l/min/m² of the area covered by the largest monitor (not less than 1,250 l/min).
    • Enough concentrate for 20 minutes on tankers with inert gas, 30 minutes without.
    • Each monitor at least 3 l/min/m² of the deck area it protects and not less than 1,250 l/min; applicators at least 400 l/min with at least 15 m throw in still air.
    • The far end of the area a monitor protects must be within 75% of its still-air throw.
    • Foam samples tested periodically (MSC.1/Circ.1312).
    The examiner may follow up with
    • Why is the expansion ratio limited to about 12 to 1?
    • Where is the main control station?
    How did you do?
  24. 24
    DeeperSOLAS Ch. II-2 Reg. 4.5.5; FSS Code Ch. 15

    What oxygen levels must an inert gas system achieve on a tanker, and why?

    Model answer points
    • Inert gas delivered to the tanks at not more than 5% oxygen by volume.
    • Cargo tank atmosphere kept at not more than 8% oxygen and at positive pressure at all times, in port and at sea, except when gas-freeing.
    • Below about 11% oxygen most hydrocarbon vapours cannot burn, so 8% gives a safety margin.
    • Supply capacity at least 125% of the maximum cargo discharge rate.
    • If oxygen in the supply exceeds 8%, alarm and action; stop cargo operations if inert gas fails.
    • Link to tanker operations.
    The examiner may follow up with
    • What is the purpose of the deck water seal?
    • What do you do if the IG plant fails during discharge?
    How did you do?
  25. 25
    DeeperSOLAS Ch. II-2 Reg. 10; IS Code 2008 (stability)

    How do you plan boundary cooling and what do you watch for?

    Model answer points
    • Cool all six sides: decks above and below, both side bulkheads, forward and aft.
    • Use spray, not heavy jets, to cool steel without wasting water.
    • Feel or measure temperatures (thermal imaging camera if carried); mark hot spots and move teams.
    • Check adjacent fuel tanks, paint stores and cargo spaces for heat transfer.
    • Control the water: pump out fire-fighting water, watch for free surface effect and list.
    • Keep a record of times and areas for the post-fire report.
    The examiner may follow up with
    • How would 200 tonnes of water in the accommodation affect GM?
    • What is a re-flash watch?
    How did you do?
  26. 26
    DeeperSOLAS Ch. II-2 Reg. 15; ISPS/ISM reporting; FSS Code Ch. 2

    As master, a fire breaks out while you are alongside in port. What are your actions and who do you inform?

    Model answer points
    • Alarm, muster and headcount; ship's fire party starts first-aid fire-fighting.
    • Call the port fire brigade and harbour master at once; inform terminal, agent and company.
    • Stop cargo and bunkering operations; consider disconnecting arms or hoses.
    • Prepare for the brigade: fire control plan from the weathertight case, crew list, cargo and dangerous goods plan, international shore connection ready, a ship's officer to guide them.
    • Watch stability and moorings as water builds up; tugs if needed to move.
    • Record times and decisions; report to flag state and company, ISM non-conformity investigation.
    The examiner may follow up with
    • Who is in charge once the shore brigade arrives?
    • When would you ask to leave the berth?
    How did you do?
  27. 27
    DeeperSOLAS Ch. II-2 Regs 4, 7, 10 and 20; MSC.532(107)

    What are the latest SOLAS Chapter II-2 amendments that entered into force in 2026?

    Model answer points
    • Entry into force 1 January 2026, resolutions MSC.520(106), MSC.532(107), MSC.550(108) and FSS Code MSC.555(108).
    • PFOS ban: no use or storage of extinguishing media containing PFOS; existing ships by the first survey on or after 1 January 2026.
    • Oil fuel flashpoint: supplier's declaration of flashpoint before bunkering.
    • Ro-ro and vehicle spaces (Reg. 20): detection, video monitoring and fixed water-based systems for weather decks; existing ships by first survey after 1 January 2028.
    • Cargo ship detection: changes to fire detection and alarm in control stations and cargo control rooms.
    The examiner may follow up with
    • How do you check that your foam is PFOS-free?
    • Why were ro-ro fire rules tightened?
    How did you do?
  28. 28
    DeeperSTCW Reg. VI/1; STCW Reg. VI/3

    Which STCW fire-fighting training must officers hold, and how often is it refreshed?

    Model answer points
    • All seafarers with safety duties: basic training including fire prevention and fire fighting (STCW Reg. VI/1, Table A-VI/1-2).
    • Officers who control fire-fighting: advanced fire fighting (Reg. VI/3, Table A-VI/3), covering fire party organisation, ship-specific systems, investigation and reporting.
    • Both need evidence of maintained standards every five years (refresher training).
    • On board: familiarisation before duties, monthly drills and the fire training manual.
    • Link the answer to your STCW certificates and the CoC revalidation.
    The examiner may follow up with
    • What does advanced fire fighting add to basic training?
    • What is in the fire training manual?
    How did you do?
  29. 29
    DeeperFSS Code Ch. 5; SOLAS Ch. II-2 Reg. 10.4

    An engine room is 6,000 m³ without the casing and 7,500 m³ with it. How much CO2 is needed?

    Model answer points
    • FSS Code Ch. 5: the larger of 40% of the gross volume without the casing or 35% including the casing.
    • 40% × 6,000 = 2,400 m³; 35% × 7,500 = 2,625 m³. Take 2,625 m³.
    • Free gas is reckoned at 0.56 m³/kg: 2,625 ÷ 0.56 = 4,687.5 kg.
    • With 45 kg cylinders that is 105 cylinders (104.2 rounded up).
    • 85% must discharge within 2 minutes: about 3,984 kg.
    • For cargo ships under 2,000 GT the percentages may be 35% and 30%.
    The examiner may follow up with
    • How much CO2 for a 12,000 m³ cargo hold?
    • Why is the casing treated differently?
    How did you do?
  30. 30
    TrapSOLAS Ch. II-2 Reg. 10.3.2.3

    Can you keep a CO2 extinguisher in your cabin corridor or mess room?

    Model answer points
    • No. SOLAS II-2/10.3.2.3: carbon dioxide extinguishers shall not be placed in accommodation spaces.
    • In a small closed space, CO2 displaces oxygen and can suffocate the user and others.
    • Use water or foam extinguishers in accommodation; CO2 or powder near electrical equipment in control stations.
    • One extinguisher for a space is stowed near its entrance.
    • The trap is answering by fire class alone without the stowage rule.
    The examiner may follow up with
    • What extinguisher is kept on the bridge?
    • Why must extinguishers show if they have been used?
    How did you do?
  31. 31
    TrapFSS Code Ch. 5; SOLAS Ch. II-2 Reg. 15

    The engine room is on fire and one oiler is missing. The chief engineer wants to release CO2 now. What do you advise the master?

    Model answer points
    • Do not release while a person may be inside unless the master decides the ship is lost otherwise; CO2 at extinguishing concentration kills.
    • Re-check the headcount at all muster points, call by radio and public address, check cabins and other spaces.
    • If time and conditions allow, send a BA search team with lifeline under cover of hoses for a quick search near escape routes.
    • Meanwhile complete shut-downs: ventilation, fuel, dampers, doors; boundary cool.
    • The release decision belongs to the master, recorded with times and reasons.
    • Examiners want to hear both the human life priority and the fact that delay can lose the ship; show the balance.
    The examiner may follow up with
    • How long can a BA team search safely?
    • What would you record in the log?
    How did you do?
  32. 32
    TrapFSS Code Ch. 3 para 2.2; SOLAS Ch. II-2 Reg. 13

    An EEBD is the nearest breathing set. Can you use it to go into a smoke-filled store and rescue a colleague?

    Model answer points
    • No. An EEBD is for escape only; it lasts at least 10 minutes and gives no protection for fire-fighting or rescue.
    • The FSS Code says EEBDs shall not be used for fighting fires, entering oxygen-deficient voids or tanks, or by fire-fighters.
    • Raise the alarm, get a team in full fire-fighter's outfit with BA and lifeline, and a backup team.
    • The rescuer who becomes a second casualty is a common pattern in accident reports.
    The examiner may follow up with
    • What do you do while waiting for the BA team?
    • Where are the nearest BA sets?
    How did you do?
  33. 33
    TrapMSC.1/Circ.1318/Rev.1 para 6.1; MSC.1/Circ.1432 para 8.1

    When you weigh CO2 cylinders, is the acceptance limit 95% or 90% of the charge?

    Model answer points
    • For CO2 systems the guidance is MSC.1/Circ.1318/Rev.1: refill any cylinder below 90% of its nominal charge.
    • The 95% figure appears in MSC.1/Circ.1432 for other fixed gas systems; Circ.1432 itself says it does not cover CO2 systems.
    • Weighing or liquid-level checks are done at least every two years (passenger ships) or at each intermediate, periodical or renewal survey (cargo ships).
    • Follow the maker's manual and flag instructions where stricter.
    • The trap is quoting one circular for every system.
    The examiner may follow up with
    • How is a cylinder's contents checked without removing it?
    • Who may do this check?
    How did you do?
  34. 34
    TrapMSC.1/Circ.1432 para 7.1; FSS Code Ch. 12

    During the annual test you start the emergency fire pump with the main fire pump still running. Is the test valid?

    Model answer points
    • No. The emergency pump must prove it can supply the required jets on its own.
    • MSC.1/Circ.1432 asks you to test the emergency fire pump with the isolation valves closed (the machinery space section isolated).
    • Check pressure at the highest and furthest hydrants with two jets running.
    • Check priming, suction lift and fuel supply; check starting arrangements.
    • A passing result with the main pump running hides a failed emergency pump.
    The examiner may follow up with
    • Why is the emergency pump outside the machinery space?
    • What is the capacity requirement?
    How did you do?
  35. 35
    TrapIS Code 2008; SOLAS Ch. II-2 Reg. 10

    You have put 300 tonnes of water into a hold to fight a fire and the ship starts to list. What has gone wrong?

    Model answer points
    • Water has gone in high up and is free to move: free surface effect reduces GM, and an off-centre weight causes list.
    • Large loss of GM can lead to a loll or capsize; several ships have been lost this way after fires.
    • Stop adding more water than needed; use spray and boundary cooling, not flooding.
    • Pump or drain water out (bilge, scuppers, portable pumps), keep track of quantities.
    • Correct the list carefully: do not counter-ballast a list caused by loll; check whether it is loll or a weight list.
    • See free surface effect and ship stability.
    The examiner may follow up with
    • How do you tell angle of loll from list?
    • How does free surface affect GM?
    How did you do?
  36. 36
    TrapSOLAS Ch. II-2 Reg. 10 (MSC.532(107)); MSC.1/Circ.1432 para 7.4 and 7.11

    Can you still use AFFF foam that has been on board since 2015?

    Model answer points
    • First check if it contains PFOS: since 1 January 2026 SOLAS II-2 bans use and storage of extinguishing media containing PFOS; existing ships comply by the first survey on or after that date.
    • If it is PFOS-free, check its condition: MSC.1/Circ.1432 requires annual periodical control tests of fixed foam concentrates (most foams not until three years after supply).
    • Sealed portable foam containers under 10 years old (not protein-based) can normally be accepted without the test.
    • Protein-based concentrates over five years old must be tested or renewed.
    • Dispose of banned foam ashore as hazardous waste with records.
    The examiner may follow up with
    • Where do you send foam samples?
    • Why was PFOS banned?
    How did you do?
  37. 37
    TrapSOLAS Ch. II-2 Reg. 10.2.3.1.1

    Is the maximum fire hose length 25 m on every open deck?

    Model answer points
    • No. 25 m applies only on open decks of ships with a maximum breadth over 30 m.
    • Otherwise: not more than 20 m on open decks and other spaces, 15 m in machinery spaces.
    • Minimum length is 10 m everywhere.
    • Examiners use this to see if you know the regulation rather than a rounded figure.
    The examiner may follow up with
    • Why a shorter hose in the engine room?
    • How many hoses must a cargo ship carry?
    How did you do?
  38. 38
    TrapFSS Code Ch. 5; SOLAS Ch. II-2 Reg. 15; resolution MSC.581(110) (enclosed space entry)

    After the CO2 release the engine room temperature is falling. The chief engineer wants to open the skylight to clear the smoke. What do you say?

    Model answer points
    • Not yet. Opening the space lets oxygen in while metal is still hot; the fire can re-ignite or flash over.
    • Keep the space sealed and boundary cooling until temperatures on all boundaries have fallen well below ignition temperatures; this can take many hours.
    • Re-entry is planned: BA team, charged hoses, backup team, entry from low level, gas and temperature readings.
    • Ventilate only after the fire is confirmed out, then test the atmosphere (oxygen, CO2, toxic gases) before entry without BA, as for an enclosed space.
    • Keep a re-flash watch afterwards.
    The examiner may follow up with
    • What gas readings would you want before entry without BA?
    • Who decides to re-enter?
    How did you do?

Reading answers is not the same as saying them. Our AI voice examiner asks these out loud, listens to your answer, asks the follow-up and marks you against the rule. Join early access or try the free timed mock oral drill.

Frequently asked questions

Is fire-fighting asked in the 2nd mate oral?

Yes. Fire-fighting is a core safety topic in the 2nd mate oral. Expect fire chemistry, classes of fire, extinguishers, the fireman's outfit and what you do as OOW when a fire alarm sounds.

How many fire pumps must a cargo ship have?

A cargo ship of 1,000 GT and over needs at least two independently driven fire pumps under SOLAS II-2/10.2.2.2. If a fire in one compartment could put both out of action, an emergency fire pump is also required.

What is the capacity of an emergency fire pump?

Under FSS Code Chapter 12 it must deliver at least 40% of the total required fire pump capacity, and not less than 25 m³/h on cargo ships of 2,000 GT and over (15 m³/h below 2,000 GT). It must still give the required pressure at the hydrants.

What are the dimensions of the international shore connection?

The flange has an outside diameter of 178 mm, inside diameter 64 mm, bolt circle 132 mm and four 19 mm slots, with four 16 mm bolts 50 mm long. It is in FSS Code Chapter 2 and must be usable on either side of the ship.

How long is a fire hose on a ship?

At least 10 m but not more than 15 m in machinery spaces and 20 m in other spaces and open decks. On open decks of ships wider than 30 m the limit is 25 m (SOLAS II-2/10.2.3.1.1).

How much CO2 is needed for an engine room?

Enough free gas for the larger of 40% of the gross volume (excluding the upper casing) or 35% including the casing, under FSS Code Chapter 5. 85% of it must be discharged within 2 minutes.

What is the difference between an EEBD and a breathing apparatus?

An EEBD is an escape device with at least 10 minutes of air, used only to get out of a dangerous atmosphere. A breathing apparatus in the fireman's outfit holds at least 1,200 litres of air (or 30 minutes) and is for fighting fire and rescue.

How often is a fire drill held on a cargo ship?

Every crew member must take part in at least one fire drill every month under SOLAS III/19. If more than 25% of the crew have not done a drill on board in the last month, a drill is held within 24 hours of leaving port.

Why is a CO2 extinguisher not kept in accommodation?

SOLAS II-2/10.3.2.3 says CO2 extinguishers shall not be placed in accommodation spaces, because CO2 in a small cabin can suffocate people. Use water or foam extinguishers there.

What changed for fire-fighting foam in 2026?

From 1 January 2026, SOLAS II-2 bans the use or storage of fire-extinguishing media containing PFOS. Existing ships had to comply by their first survey on or after that date.

How often are fire hoses pressure tested?

MSC.1/Circ.1432 asks for an annual pressure test of a sample of hoses at maximum fire main pressure, so that every hose has been tested within five years.

What does A-60 mean?

An A class division is steel or equivalent that stops smoke and flame for one hour in the standard fire test. The 60 means the insulation keeps the unexposed side's average temperature rise within 140°C (and no point over 180°C) for 60 minutes.

Sources 10 documents

Each number in the text links to the source below. Labels show the type of source; see our editorial policy.

  1. Official Cayman Islands Shipping Notice CISN 2014/01 Rev 2, with MSC.1/Circ.1432 and MSC.1/Circ.1516 annexed
  2. Official Hong Kong Marine Department MSIN 2136, Annex 1: MSC.1/Circ.1318/Rev.1 · 25 May 2021
  3. Official IMO Resolution A.951(23): Improved guidelines for marine portable fire extinguishers · 5 December 2003
  4. Official MGN 713 (M): Fire protection regulations - adoption of amendments in IMO resolutions in force on 1 January 2026 · 15 December 2025
  5. Official IMO SOLAS Consolidated Edition supplement (December 2014) · 1 December 2014
  6. Official IMO: Raft of shipping rules in force from 1 January 2026
  7. Official IMO: Amendments to IMO instruments - upcoming and recent entry into force dates
  8. Official IMO Resolution MSC.550(108) (adopted 23 May 2024) · 23 May 2024
  9. Official IMO Resolution MSC.98(73), International Code for Fire Safety Systems (FSS Code), Chapter 5 · 5 December 2000
  10. Official IMO Resolution MSC.98(73), FSS Code Ch. 12 para 2.2.1.1 · 5 December 2000

Where should you go next?

  • Oral topics14 pages: examiner questions with model answer points, deck and engine
  • Question banks7 pages: free MCQ sets with answers and explanations
  • CoC exam guides16 pages: every oral and written exam, authority by authority
  • Free tools4 pages: mock oral drill, lights trainer, sea-time calculator, practice tests
Exam Prep DeskMaritime exam researchers

We write from the conventions (STCW, COLREG, SOLAS, MARPOL), the authorities' own notices and published syllabi, and cite the source for every fee, rule and date. We are independent and not linked to any maritime administration or test provider. Found an error? It matters at sea: tell us and see how we correct · Disclaimer.

Related guides

AI voice mock oral

Say it out loud before the examiner asks.

Our examiner asks CoC oral questions by rank and function, listens to your answer, asks the follow-up and scores you against the rule. Early access is open for India first.

  • Deck and engine, every rank
  • Answers referenced to the conventions
  • Independent, not linked to any authority
WhatsApp us