On this page
- Key facts
- How should you use this CES engine practice set?
- Which rules and numbers come up most in engine CES-style tests?
- What traps catch engineers in screening tests?
- How do you work the calculation questions in a CES engine test?
- Which traps does this CES engine set use, and what is the rule?
- CES engine revision table
- Where is this engine knowledge examined besides company tests?
- What should you do after finishing this set?
- 40 practice questions
- Frequently asked questions
- Sources
Key facts
- Questions
- 38 original MCQs
- Who it is for
- Engine cadets, 4/E, 3/E, 2/E, ETO
- Subjects
- Main and auxiliary engines, purifiers, boilers, electrical, pumps, MARPOL, safety
- Suggested pace
- About 1 minute per question (our estimate)
- Real CES bank size
- Over 6,500 questions[1]
- Real CES pass mark
- Set by each company[1]
- Cost
- Free
Checked 14 November 2026. Fees and rules change: confirm with the authority before you book.
How should you use this CES engine practice set?
Treat this set as a timed rehearsal for a company's Seagull CES test for engineers, then study every explanation. All 40 questions were written by us around STCW engine-department knowledge. They are not CES items and nothing here is copied from a test bank.
Engine CES tests are department-specific and the vendor says it can also build vessel-specific and company-specific tests from a bank of over 6,500 questions[1]. In practice that means questions on main and auxiliary engines, electrical plant, pumps, purifiers, boilers, refrigeration, pollution rules and engine-room safety, mixed together.
How to work through it:
- Sit all 40 questions in one go with a timer, at about one minute per question. We estimate this is close to the pace most candidates need; your company sets the real limit.
- Mark every guess, even correct ones.
- Study each weak area on its topic page: two-stroke main engine, fuel oil purifiers, marine boilers, marine electrical systems, steering gear, oily water separator.
- Repeat the set after three days, then go deeper with main engine MCQs and marine electrical MCQs.
- Finish with a mixed run in the practice test tool.
For what changes at second engineer and chief engineer level, read CES for engineers.
Which rules and numbers come up most in engine CES-style tests?
A short list of limits and intervals appears again and again in engine screening tests. Learn them with the rule number so you can answer in seconds.
| Topic | What to know | Reference |
|---|---|---|
| Oily bilge discharge | Not more than 15 ppm, ship en route, approved equipment working | MARPOL Annex I Reg. 15 |
| Oil Record Book | Kept 3 years after the last entry | MARPOL Annex I Reg. 17 |
| Sulphur in fuel | 0.50% m/m globally; 0.10% m/m inside ECAs | MARPOL Annex VI Reg. 14 |
| NOx Tier III | North American and US Caribbean ECAs for ships built from 1 Jan 2016; Baltic and North Sea from 1 Jan 2021 | MARPOL Annex VI Reg. 13 |
| Steering gear | 35° to 35°; 35° to 30° in not more than 28 s | SOLAS Ch. II-1 Reg. 29 |
| Emergency steering drill | At least every three months | SOLAS Ch. V Reg. 26.4 |
| Fuel flashpoint | Minimum 60°C (limited exceptions) | SOLAS Ch. II-2 Reg. 4 |
| Critical equipment | Identify and maintain under the SMS | ISM Code Section 10.3 |
| Hours of rest | At least 10 h in any 24 h and 77 h in any 7 days | MLC Standard A2.3 |
| Enclosed space | Ventilate, test, permit, rescue plan | SOLAS Ch. XI-1 Reg. 7; IMO Res. MSC.581(110) |
What traps catch engineers in screening tests?
Most engineers who lose marks know the machinery but misread the question or swap two figures. Watch for these.
- 15 ppm vs 30 litres per mile. The first is for machinery-space bilge water; the second is a tanker cargo-area limit. See MARPOL and the oily water separator page.
- 0.50% vs 0.10% sulphur. Global cap vs ECA. See fuel sulphur rules and scrubbers.
- Gravity disc direction. A bigger disc moves the interface outwards. Many candidates learn it the wrong way round.
- Opening the crankcase too early. The safe answer always includes cooling time. See auxiliary diesel engines for the same logic on generators.
- Synchroscope direction. Close the breaker on slow clockwise rotation just before 12 o'clock, not when the pointer is stopped somewhere else.
- First action questions. When a question asks for the first action in an emergency, choose the one that makes people safe or removes fuel and air, not the repair. See engine room watchkeeping.
- Rank wording. A question may say 'the duty engineer' or 'the chief engineer'. The right answer can change with who has the authority.
How do you work the calculation questions in a CES engine test?
CES-style engine tests mix in a few short calculations. Each one takes under two minutes if you write the formula first and keep the units. These are the four types we see most often in engineering practice sets.
Example 1: propeller slip (question 39). Engine speed in knots = pitch (m) × rpm × 60 ÷ 1,852. With 5.0 m pitch and 100 rpm: 5.0 × 100 × 60 = 30,000 m per hour, and 30,000 ÷ 1,852 = 16.20 kn. Apparent slip = (engine speed − ship speed) ÷ engine speed = (16.20 − 14.0) ÷ 16.20 = 0.136, or 13.6%. Always divide by the engine speed. Negative slip is possible with a strong following current, because ship speed over the ground can exceed engine speed.
Example 2: indicated power from a power card (question 31). Indicated power per cylinder = mean indicated pressure × swept volume × power strokes per second. Take a two-stroke cylinder with a mean indicated pressure of 18 bar (1,800,000 Pa), a bore of 0.60 m and a stroke of 2.40 m at 90 rpm. Piston area = π × 0.30² = 0.2827 m². Swept volume = 0.2827 × 2.40 = 0.6786 m³. A two-stroke fires every revolution, so strokes per second = 90 ÷ 60 = 1.5. Power = 1,800,000 × 0.6786 × 1.5 = 1,832,000 W, about 1,832 kW per cylinder. On a four-stroke you would halve the strokes per second. The enclosed area of the card gives the mean indicated pressure once you divide by the card length and apply the spring scale.
Example 3: fuel consumption per day. A main engine at 12,000 kW with a specific fuel oil consumption of 175 g/kWh burns 12,000 × 24 × 175 = 50,400,000 g, that is 50.4 tonnes per day. If the bunker figure on board says 46 tonnes, the difference is too big to ignore: check soundings, the flowmeter and the density used.
Example 4: insulation resistance trend (question 16). A motor measured 50 MΩ last month and 2 MΩ today with the same tester at a similar temperature. The absolute value may still pass a low limit, but a fall of 96% in a month means moisture or contamination. The CES answer is to investigate and dry or clean the winding, not to accept it because it is above the minimum.
Examiner's note: In a company technical interview the follow-up to a slip question is usually "what does a rising slip tell you?" The strong answer: fouled hull or propeller, or heavy weather, so you compare slip at the same draught and weather over several voyages before blaming the engine.
Which traps does this CES engine set use, and what is the rule?
The common-traps list above names the mix-ups. This table goes one step further: it shows which questions use each pattern and the rule you can apply in the test when the wording changes.
| Trap pattern | Questions | Rule that defeats it |
|---|---|---|
| Repair before safety | 1, 3, 35, 36 | In a scavenge fire, oil mist alarm or engine room fire, the first action reduces fuel, air or load and keeps people safe. Opening, inspecting or repairing comes after cooling, ventilation and a permit. |
| Direction reversed | 4, 17 | A larger gravity disc moves the interface outwards and oil goes out with the water. On earth lamps, the dim lamp marks the faulty phase, not the bright ones. |
| Cycle states swapped | 9, 10 | Compressor out: high-pressure superheated vapour. Expansion valve out: low-pressure wet mixture. Condenser out: high-pressure liquid. |
| Similar numbers, different rule | 11, 13, 32, 38 | 15 ppm (bilges), 0.10% (ECA sulphur), 60 °C (fuel flash point), Tier III only in NOx ECAs. Read which annex and which area the question names. |
| Steering angles mixed | 14, 15 | Main gear: 35° one side to 30° the other within 28 s at deepest draught and full speed. Emergency steering drills at least every three months. |
| Governor vs AVR | 18, 30 | The governor holds speed and frequency and shares kW; kVAr belongs to the AVR. |
| Protection devices confused | 19, 20 | Reverse power trips a set being motored; preferential trips shed non-essential loads on overload. |
| Pump type confused | 21, 22 | Centrifugal pumps cavitate when NPSH is low. Reciprocating pumps are positive displacement, so they need a discharge relief valve. |
| Absolute value vs trend | 16, 25, 28 | A salinometer alarm dumps water; a crackle test shows water in oil; falling insulation resistance is a warning even above the limit. |
| Wrong formula base | 39 | Slip is divided by engine speed, not ship speed. |
| Tank valve rule | 40 | Tanks of 500 litres and above, above the double bottom: valve on the tank closable from outside the space. |
When two answers look possible, choose the one that matches the exact rule wording ("within 28 seconds", "outside the space", "automatically stop"), not a general good practice.
CES engine revision table
Ten lines to reread before the test. Each line maps to the questions that test it.
| Topic | Recall | Questions |
|---|---|---|
| Crankcase and scavenge safety | Slow down, cut fuel, stop; wait to cool before opening | 1–3 |
| Purifier | Larger gravity disc moves interface outwards | 4 |
| Boilers | Low water overheats tubes; chlorides mean sea water; blow down removes sludge | 6–8 |
| Refrigeration | Superheated vapour leaves the compressor; TXV holds superheat | 9, 10 |
| MARPOL | 15 ppm with alarm and auto-stop; 0.10% in ECAs; Tier III in NOx ECAs | 11–13, 38 |
| Steering gear | 35° to 30° within 28 s; drills every three months | 14, 15 |
| Electrical | Megger for insulation; dim earth lamp is the faulty phase; close just before 12 | 16–20 |
| Pumps | Low NPSH causes cavitation; reciprocating pumps need relief valves | 21, 22 |
| Starting air and fuel | Flame arresters; drain receivers; 60 °C flash point; remote tank valves | 23, 24, 32, 40 |
| Performance | Power card area = work per cycle; slip divided by engine speed | 31, 39 |
Where is this engine knowledge examined besides company tests?
The same knowledge is examined for your certificate, so practice here also helps your next CoC exam. The vendor says CES was built to check that crew hold the STCW knowledge their certificates require[2].
- India: MEO Class 4 oral and MEO Class 2 oral.
- UK: MCA EOOW oral and MCA second engineer oral.
- Philippines: MARINA officer exams.
Most companies follow the CES with a technical interview. Read marine engineer interview questions and practise speaking with the mock oral drill. Our AI voice examiner, which asks questions aloud and follows up, is open for early access.
What should you do after finishing this set?
After the set, write down every number you missed and fix your two weakest systems before you take another mixed test. Then continue with pumps and purifiers MCQs, marine boilers MCQs, refrigeration MCQs and MARPOL MCQs. Other topics worth a read: air compressors and starting air, fresh water generator, refrigeration and air conditioning, pumps and pumping systems and UMS and automation. Before you sign on, use the joining a new company checklist.
Practice set
40 practice questions with answers
Pick an answer to see if it is right and why. Your score stays on this page only.
- 1
On a two-stroke main engine you suspect a scavenge fire in one unit. What is the correct first action?
Show answer
Answer: B. Slowing down and cutting fuel to the unit removes heat, and extra cylinder oil protects the liner. Opening the scavenge doors while the fire is active lets in air and can spread it. Fixed extinguishing is used only if the fire does not die out.
- 2
What does an oil mist detector on a main engine crankcase do?
Show answer
Answer: D. A hot spot on a bearing or piston rod evaporates oil, which condenses into a fine mist. The detector warns early so the engine can be slowed or stopped before the mist reaches an explosive mixture.
- 3
After an oil mist alarm, why must the crankcase doors not be opened straight after the engine is stopped?
Show answer
Answer: A. A hot spot plus oil mist plus fresh air is the recipe for a crankcase explosion. The engine must be left to cool for the time the maker states before the doors are opened.
- 4
In a fuel oil purifier, what happens if the gravity disc chosen is too large for the oil density?
Show answer
Answer: C. A larger gravity disc moves the oil-water interface outwards towards the bowl wall. If it goes too far, the water seal breaks and oil is lost through the water outlet. Heavier oils need a smaller disc.
- 5
What is the job of the viscosity controller in the fuel system of a diesel engine running on heavy fuel?
Show answer
Answer: B. Heavy fuel must be heated to bring its viscosity into the range the injection system needs. The controller measures viscosity and adjusts steam or electric heating to hold it there.
- 6
What is the main danger of a very low water level in a running boiler?
Show answer
Answer: D. When heating surfaces are not covered by water they overheat quickly and can bulge or rupture. That is why low-low water level trips the burner.
- 7
A boiler water test shows a sudden rise in chloride level. What is the most likely cause?
Show answer
Answer: A. Chloride comes from sea water. A sudden rise points to a leak, often in the condenser or a drain cooler, and must be traced before it causes scale and corrosion.
- 8
Why is a boiler blown down?
Show answer
Answer: C. Bottom blow-down removes settled sludge and surface blow-down removes scum and dissolved solids, keeping the water within treatment limits. Blowing down overboard must respect local rules.
- 9
In a vapour compression refrigeration system, in what state does refrigerant leave the compressor?
Show answer
Answer: B. The compressor raises the pressure and temperature of the vapour, so it leaves as high-pressure superheated gas. It then gives up heat and condenses in the condenser.
- 10
What does the thermostatic expansion valve do in a refrigeration plant?
Show answer
Answer: D. The valve throttles liquid refrigerant to evaporator pressure and controls the flow by sensing superheat at the evaporator outlet. Too little flow starves the evaporator, too much floods it.
- 11
Under MARPOL Annex I, what is the maximum oil content of effluent that a ship outside special areas may discharge from machinery spaces through the oily water separator?
Show answer
Answer: A. Machinery-space oily bilge water may be discharged only when the ship is en route, the oil content without dilution does not exceed 15 ppm and the approved equipment is working. 30 litres per nautical mile is a cargo-area limit for oil tankers.
- 12
What should the 15 ppm bilge alarm do when the oil content of the effluent exceeds the limit?
Show answer
Answer: C. Annex I requires the 15 ppm equipment to give an alarm and to stop the discharge automatically, or recirculate it, when the effluent goes above 15 ppm. An alarm alone is not enough, and diluting the effluent to get under the limit is prohibited; tampering with the system is a serious offence.
- 13
What is the maximum sulphur content of fuel oil used inside a sulphur emission control area?
Show answer
Answer: B. Inside an ECA the limit is 0.10% m/m. The global limit outside ECAs has been 0.50% m/m since 1 January 2020. Fuel changeover must be logged before entering the ECA.
- 14
Under SOLAS, what must the main steering gear be able to do at maximum ahead service speed and deepest draught?
Show answer
Answer: D. The main steering gear must move the rudder from 35° to 35°, and from 35° on either side to 30° on the other in not more than 28 seconds, at deepest seagoing draught and maximum ahead service speed. The 28-second limit applies to the 35° to 30° movement, not 35° to 35°; 15° to 15° in 60 seconds is the auxiliary steering gear requirement at half speed or 7 knots.
- 15
How often must emergency steering drills be held?
Show answer
Answer: A. SOLAS Chapter V requires emergency steering drills at least once every three months, including direct control from the steering gear compartment and the communication procedure with the bridge. Checking and testing the steering gear within 12 hours before departure is a separate requirement, which is why the last option tempts.
- 16
Which instrument is used to measure the insulation resistance of a motor winding?
Show answer
Answer: C. An insulation resistance tester applies a test DC voltage and reads resistance in megohms. A falling trend over time is as important as one low reading.
- 17
On a 440 V insulated neutral system, the earth lamps show one lamp dim and the other two brighter. What does this indicate?
Show answer
Answer: B. With an earth fault on one phase that phase's lamp goes dim or dark, while the lamps on the other two phases glow brighter. Find and clear the fault, because a second earth on another phase causes a short circuit.
- 18
When paralleling an incoming generator using a synchroscope, when should the breaker be closed?
Show answer
Answer: D. Slow clockwise rotation means the incoming machine is slightly faster, so it takes load at once. Closing just before 12 o'clock allows for the breaker closing time. Voltage and frequency must also be matched.
- 19
What does a reverse power trip protect against?
Show answer
Answer: A. If a prime mover loses fuel or power, its alternator can draw power from the busbar and run as a motor. The reverse power relay trips its breaker to protect the engine and the plant.
- 20
What is the purpose of a preferential trip system?
Show answer
Answer: C. Preferential tripping drops non-essential loads such as galley or air conditioning in stages, so the essential services stay on when the running generators are overloaded.
- 21
What is the most likely cause of cavitation in a centrifugal pump?
Show answer
Answer: B. When suction pressure falls too low, vapour bubbles form and then collapse at the impeller, causing noise and pitting. A high suction tank level actually helps by adding suction head; check strainers, suction valves and liquid temperature.
- 22
Why must a reciprocating pump have a relief valve on the discharge side?
Show answer
Answer: D. A positive displacement pump keeps delivering fluid whatever the back pressure. If the discharge is closed, pressure rises until something fails unless a relief valve opens. Pulsation is smoothed by an air vessel, not the relief valve.
- 23
What is the purpose of the flame arrester or bursting disc fitted in the starting air line near each cylinder?
Show answer
Answer: A. If a starting air valve leaks, hot combustion gas can enter the air line and ignite oil deposits. The arrester and bursting disc limit the effect of such an explosion.
- 24
Why are starting air receivers drained regularly?
Show answer
Answer: C. Compressed air carries moisture and some compressor oil, which settle in the receiver. Draining removes them before they cause corrosion, freezing or an oil fire.
- 25
A fresh water generator's salinometer shows high salinity. What should happen to the product water?
Show answer
Answer: B. The salinometer controls a dump valve. Water above the set salinity is sent away from the storage tanks so it cannot contaminate drinking or boiler water.
- 26
Before fresh water from the evaporator is used for drinking, what must be done?
Show answer
Answer: D. Distilled water is too pure to be pleasant or healthy to drink and may pick up bacteria in tanks. It is normally mineralised and disinfected before use as drinking water.
- 27
Why is jacket cooling water treated with a chemical inhibitor?
Show answer
Answer: A. Treatment such as nitrite-based inhibitors protects the cooling spaces from corrosion and scale. Chloride and inhibitor levels are tested regularly.
- 28
Which simple on-board test checks lubricating oil for water?
Show answer
Answer: C. A drop of oil on a hot plate crackles if it contains water. It is a quick check before sending a sample for laboratory analysis.
- 29
Which of these is a common cause of turbocharger surging?
Show answer
Answer: B. Surging happens when the compressor cannot deliver against the air pressure in the receiver. Fouling, damage and sudden load changes are typical causes.
- 30
What is the main job of the governor on a diesel generator engine?
Show answer
Answer: D. The governor adjusts fuel to hold speed as electrical load rises and falls, which keeps frequency steady and shares active load (kW) in parallel. Reactive load (kVAr) sharing is the job of the automatic voltage regulator, not the governor.
- 31
On a power card (indicator diagram) taken from a cylinder, what does the area enclosed by the diagram represent?
Show answer
Answer: A. The enclosed area is proportional to the work done per cycle. With the mean indicated pressure from the area, you can calculate indicated power and compare cylinders.
- 32
Under SOLAS, what is the general minimum flashpoint of fuel oil used on board?
Show answer
Answer: C. SOLAS sets a minimum flashpoint of 60 °C for oil fuel, with limited exceptions such as 43 °C fuel for emergency generators. From 1 January 2026 the ship must also be given a declaration of the flashpoint, or that it is at or above 70 °C, before bunkering.
- 33
Before bunkering starts, what should be done on deck to prevent oil reaching the sea?
Show answer
Answer: B. Plugged scuppers keep any spill on deck, and SOPEP equipment must be ready. Agreed pumping rates, communication and tank sounding plans are also set before starting.
- 34
On a ship with periodically unattended machinery spaces, what is the dead-man (engineer safety) alarm for?
Show answer
Answer: D. An engineer who enters an unattended machinery space alone must reset the dead-man alarm at set intervals; if it is not reset, it alarms on the bridge and in the accommodation so help is sent. Calling engineers from their cabins is the separate engineers' alarm required by SOLAS Reg. 38.
- 35
In an engine room fire, which controls outside the space help to stop the fire spreading?
Show answer
Answer: A. SOLAS requires means to stop ventilation and fuel oil pumps and to close fuel tank outlet valves from outside the space. Cutting fuel and air is the first step before fixed fire-fighting.
- 36
Before an engineer enters a main engine scavenge space or crankcase for inspection, what must be in place?
Show answer
Answer: C. Crankcases and scavenge spaces can be enclosed spaces. They must be ventilated and the atmosphere tested, starting air and turning gear made safe, and the company permit followed. Engaging the turning gear is part of immobilising the engine but is not enough on its own.
- 37
Under the ISM Code, what must the company do for equipment whose sudden failure may result in hazardous situations?
Show answer
Answer: B. Section 10.3 of the ISM Code asks the company to identify critical equipment and systems and to include specific measures, such as regular testing of stand-by units, in the planned maintenance system.
- 38
In which emission control area do NOx Tier III limits apply to engines on ships built on or after 1 January 2016?
Show answer
Answer: D. Tier III applies in the North American and US Caribbean Sea ECAs to ships built from 1 January 2016. For the Baltic and North Sea NOx ECAs the date is 1 January 2021.
- 39
A propeller has a pitch of 5.0 m and turns at 100 rpm. The ship makes 14.0 knots through the water. What is the apparent slip?
Show answer
Answer: A. Engine distance per hour = 5.0 × 100 × 60 = 30,000 m = 16.20 nm, so engine speed is 16.20 kn. Slip = (16.20 − 14.0) ÷ 16.20 = 13.6%. Dividing by the ship's speed instead gives 15.7%; 2.2 is the speed difference in knots, not a percentage.
- 40
A 2 m³ fuel oil daily service tank sits above the double bottom in the engine room. Under SOLAS, the outlet valve on the tank must be:
Show answer
Answer: C. Tanks of 500 litres and above situated above the double bottom need a valve on the tank that can be closed from a safe position outside the space, so a fire fed by a broken pipe can be starved of fuel. A local-only valve cannot be reached in a fire.
Reading answers is not the same as saying them. Our AI voice examiner asks these out loud, listens to your answer, asks the follow-up and marks you against the rule. Join early access or try the free timed mock oral drill.
Frequently asked questions
Are these the real CES engine questions?
No. Every question here is our own, written around STCW engine knowledge and the conventions. We do not copy or reproduce CES items. The set trains the same knowledge and the same pace.
How many questions are in an engine CES test?
The vendor does not publish a fixed number. Tests are built by rank, department and vessel type, and companies can make their own. Ask the crewing office about question count and time before you sit it.
What score do I need on an engine CES test?
Each company sets its own pass mark and it may differ by rank. See what is a good CES score for how results are usually read.
Do ETOs take the same CES test as engineers?
Usually not. The vendor describes rank- and department-specific tests, so an electro-technical officer would normally get an electrical-focused test. Check with the company which test you are booked for.
Will I get questions on my ship type?
Possibly. Vessel-specific tests exist, so a tanker engineer may see cargo pump, inert gas and tank cleaning machinery questions, while an LNG engineer may see boil-off and gas handling questions.
How should a fourth engineer prepare?
Focus on watchkeeping, purifiers, pumps, compressors, OWS and basic electrical safety. Use this set and the main engine MCQs, then read marine engineer interview questions.
How should a second engineer prepare?
Add maintenance planning, critical equipment under the ISM Code, crankcase and scavenge safety, and emission rules. Expect deeper questions on why, not only what.
Can I retake a CES test?
That depends on the company. Some allow a retake after study, some use the first result. Use any wrong-answer feedback to revise before trying again.
Does the CES test include calculations?
Engine tests can include simple calculations such as fuel consumption or power from an indicator card. Practise basic formulas and keep a calculator handy if the company allows one.
Is there a separate English test?
Many companies also use an English test such as Marlins. See the Marlins English test page and CES vs Marlins.
Where can deck officers practise?
Deck officers should use our CES deck practice set, which covers COLREG, stability, safety and pollution rules.
Sources 2 documents
Each number in the text links to the source below. Labels show the type of source; see our editorial policy.
- Reported OneOcean: CES as a maritime recruitment and onboarding tool · 20 December 2024
- Reported OneOcean: Improving Port State Control Performance with the OneOcean Crew Evaluation System (CES) · 11 October 2024