NautemyCoC orals · exams · job testsEarly access
Oral topic28 min readJump to 35 questions

Oily water separator oral exam questions and model answers for marine engineers

Oily water separator oral questions start with the 15 ppm rule and all its conditions (en route, through approved equipment, not in the Antarctic), then how the separator and the 15 ppm bilge alarm work, how you record each operation in the Oil Record Book, and why tampering ends careers.

On this page
  1. Key facts
  2. What do examiners ask about the oily water separator at each rank?
  3. What are the MARPOL rules for discharging machinery space bilge water?
  4. How does an oily water separator and 15 ppm bilge alarm work?
  5. Which Oil Record Book codes do you use for OWS operations?
  6. How should you structure an OWS answer in the oral?
  7. What mistakes do candidates make on the OWS?
  8. Which OWS situations do examiners give you?
  9. What do port State inspectors check on the OWS?
  10. How do you fault-find an oily water separator that keeps alarming?
  11. What makes an OWS answer strong rather than weak?
  12. What should you read to revise the OWS?
  13. Which other engine topics link to the OWS?
  14. 35 practice questions
  15. Frequently asked questions
  16. Sources

Key facts

Discharge limit
15 ppm oil, undiluted, ship en route
Equipment rule
MARPOL Annex I Reg. 14 (400 GT and above)
Discharge rule
MARPOL Annex I Reg. 15
Equipment standard
MEPC.107(49), equipment fitted from 1 January 2005[1]
Bilge alarm records
Stored at least 18 months[1]
Bilge alarm calibration
By maker, at most every 5 years[2]
Antarctic area
No oil discharge at all
Examined at
MEO Class 4, 2 and 1 (India); MCA EOOW, Second and Chief Engineer

Checked 14 November 2026. Fees and rules change: confirm with the authority before you book.

What do examiners ask about the oily water separator at each rank?

The OWS is asked at every engine rank, but the depth changes: a Class 4 candidate must operate and record it correctly, while a Class 2 or Class 1 candidate must manage the system, defend the records in a port State inspection and set up the ship's procedures.

The questions sit in the marine engineering function and in the pollution prevention part of the 'controlling the operation of the ship' function. The topic overlaps with the deck MARPOL oral topic, so expect the same 15 ppm question to come from both sides. For the regulation context, see the oily water separator glossary entry and the MARPOL glossary entry.

OWS questions by exam and rank (our view of typical depth)
ExamLevelWhat you must show
India MEO Class 4OperationalStart, run and stop the OWS; read the 15 ppm alarm; Reg. 15 conditions; write Code D and Code C entries
India MEO Class 2Management (second engineer)Fault-finding, emulsions, bilge management plan, alarm calibration certificate, PSC checks, sludge tank rules
India MEO Class 1Management (chief engineer)Company procedures, seals and access control, crew training, whistle-blower culture, consequences of a magic pipe, IOPP survey
MCA EOOW oralOperationalScenario: alarm sounds during pumping, what do you do and what do you record
MCA Second Engineer oralManagementDesign of the system, maintenance, why centrifugal feed pumps are a bad idea, testing the alarm
MCA Chief Engineer oralManagementLegal exposure, audits, Oil Record Book signatures, dealing with a reported bypass

What are the MARPOL rules for discharging machinery space bilge water?

A ship of 400 GT and above may discharge machinery space bilge water only if it is en route, the mixture passes through approved oil filtering equipment, the undiluted oil content is 15 ppm or less, and (for tankers) it is not from cargo pump-room bilges or mixed with cargo residues. In the Antarctic area no oil discharge is allowed at all.

Inside other Annex I special areas the same conditions apply, but the equipment must have the 15 ppm alarm with automatic stopping (Reg. 14.7). The Annex I special areas are the Mediterranean, Baltic, Black Sea, Red Sea, Gulfs area, Gulf of Aden, Antarctic, North West European waters, Oman area of the Arabian Sea and Southern South African waters (the Red Sea, Gulf of Aden and Oman area rules are not yet in effect)[3]; our MARPOL topic covers them in full.

MARPOL Annex I numbers for the engine room
ItemRuleWhere
Oil filtering equipment requiredShips of 400 GT and aboveAnnex I Reg. 14.1
Alarm and automatic stopping device requiredShips of 10,000 GT and above (and any ship discharging in a special area)Annex I Reg. 14.2, 14.7, 15.3
Oil content of effluentNot more than 15 ppm, without dilutionAnnex I Reg. 14.6, 15.2
Ship conditionEn routeAnnex I Reg. 15.2.1
Antarctic areaAny discharge of oil or oily mixture prohibitedAnnex I Reg. 15.4
Sludge tank pipingNo direct overboard connection other than the standard discharge connectionAnnex I Reg. 12
Oil Record Book retentionThree years after the last entryAnnex I Reg. 17
Bilge alarm data storageAt least 18 monthsMEPC.107(49) para 4.2.9
Bilge alarm response timeNot more than 5 secondsMEPC.107(49) para 4.2.6
Bilge alarm accuracy checkBy maker or authorised person, at most 5 years from commissioning or maker's shorter termMEPC.285(70)

How does an oily water separator and 15 ppm bilge alarm work?

A bilge separator first separates oil by gravity, helped by coalescing plates or packing, then polishes the water in a second stage (coalescing filter, absorbent cartridge, membrane or a flocculation unit). Separated oil is drawn off to the sludge or bilge oil tank when an oil-water interface probe senses oil.

The feed pump is a slow positive displacement pump (screw or piston type) so the oil droplets are not broken up. A centrifugal pump would shear the oil into a fine emulsion that gravity cannot separate. Some units pull the mixture through the separator by suction instead of pushing it, for the same reason.

The 15 ppm bilge alarm takes a continuous sample from the overboard line and measures oil content optically, usually by light scattering and absorption. If the reading goes above 15 ppm, or the alarm fails or is not ready, it sounds and the automatic stopping device (a three-way valve or overboard valve interlock) sends the effluent back to the bilge tank instead of overboard. Under MEPC.107(49) the alarm must respond within 5 seconds and store date, time, alarm status and separator status for at least 18 months.[1]

Main parts and what examiners ask about them
PartJobTypical question
Bilge holding tankLets oil and water settle before processingWhy draw from the bottom, not the top?
Positive displacement feed pumpMoves the mix gentlyWhy not a centrifugal pump?
First stage (gravity and coalescer plates)Removes free oilWhat stops it working? (emulsion, sludge, cold oil)
Second stage (filter, absorber or membrane)Takes effluent below 15 ppmWhen do you renew the elements?
Oil level probe and drain valveSends separated oil to sludge tankWhat happens if the probe fouls?
15 ppm bilge alarmMeasures effluent oil contentHow is it protected from tampering?
Automatic stopping device or three-way valveStops overboard discharge on alarmWhat does 'fail safe' mean here?
Clean water flushing lineCleans the cell and separatorWhy must the alarm sound when it is open?

Which Oil Record Book codes do you use for OWS operations?

Machinery space operations go in Oil Record Book Part I, using the letter codes from IMO's guidance, and each entry is signed by the officer in charge with each completed page signed by the master. Since 1 October 2020 the flag State may also approve an electronic Oil Record Book in place of the paper book.[4]

Examiners often hand you a scenario and ask for the code. Learn the letters below and the item numbers that go with them from the ORB itself.

Oil Record Book Part I codes for machinery spaces
CodeOperationOWS example
ABallasting or cleaning of fuel oil tanksRare on modern ships
BDischarge of dirty ballast or cleaning water from fuel tanksRare
CCollection, transfer and disposal of oil residues (sludge)Weekly sludge tank soundings; transfer to incinerator or shore
DNon-automatic discharge overboard, transfer or disposal of bilge waterPumping the bilge holding tank through the OWS
EAutomatic discharge overboard of bilge waterShips with automatic bilge pumping through the OWS
FCondition of the oil filtering equipmentOWS or alarm failure and repair
GAccidental or other exceptional discharges of oilAny spill or discharge outside the rules
HBunkering of fuel or bulk lubricating oilNot an OWS entry
IAdditional operational procedures and general remarksBilge tank transfers not covered elsewhere, as guidance allows

How should you structure an OWS answer in the oral?

Start with the rule, then the equipment, then the record. For '15 ppm' questions say the four conditions first (en route, approved equipment, 15 ppm undiluted, not from cargo pump-room bilges on tankers), then special areas and the Antarctic. Only then describe the machine.

For 'walk me through' questions, use the order you would follow on board: permission and checks, line-up, start, monitor, stop, flush, record. Name the Oil Record Book entry at the end; examiners mark you down if you forget the paperwork.

For fault questions, split the cause into feed (wrong tank, emulsion, solids, air), separator (fouled plates, oil probe, heater), and monitor (dirty cell, air bubbles, sample line). Practise saying this out loud with our mock oral drill; the how to answer oral questions guide explains the same method for every topic.

What mistakes do candidates make on the OWS?

Most marks are lost on conditions and records, not on the machine.

Which OWS situations do examiners give you?

Expect at least one practical scenario. The procedure below is the one most often asked as 'walk me through pumping bilges'. Always follow your ship's SMS and the chief engineer's standing orders; the steps describe the principle.

  1. 1
    Check you are allowed to discharge

    Confirm with the bridge that the ship is en route, outside the Antarctic area, and note position; inside a special area confirm the alarm and automatic stop are working. Check company rules, which are often stricter (some forbid discharge within port limits or coastal zones).

  2. 2
    Check the system

    Sound the bilge holding tank and sludge tank, check the separator is full of clean water, check the 15 ppm alarm is powered and reads zero on clean water, and check the seals on the alarm and overboard valve.

  3. 3
    Line up and start

    Open the suction from the bilge holding tank, start the feed pump, let the effluent recirculate until the alarm reads steady below 15 ppm, then allow overboard discharge as the system design permits.

  4. 4
    Monitor

    Stay near the unit. Watch the ppm reading, oil drain operation, pressures and the tank level. Stop at once if the reading climbs, the oil probe fails or the bridge reports a sheen.

  5. 5
    Stop and flush

    Stop the feed, flush the separator with clean water as the maker requires (the alarm will read high or alarm when clean water reaches the cell, which is intended), and close the overboard valve.

  6. 6
    Record

    Make the Code D entry: quantity discharged, tank, start and stop time and positions, and confirm the tank soundings agree with the quantity. Sign it.

What do port State inspectors check on the OWS?

Inspectors check the condition and operation of the separator, and Australia's AMSA treats a 15 ppm alarm that fails to stop the discharge when no representative sample reaches it as non-compliance[5]. They also look for bypass arrangements and compare the Oil Record Book with tank soundings and the 15 ppm alarm memory.

They compare the alarm's stored data (date, time, alarm status and separator status, kept for 18 months) against the ORB Code D entries. They look for flanges with fresh paint, spare pipes or hoses near the overboard line, and sludge quantities that do not match the fuel burned. A bypass ('magic pipe') can lead to detention, criminal prosecution of the engineers and the company, and loss of the CoC. The legal side is covered in our SOLAS and ISM Code topics, because a bypass is also a failure of the safety management system.

How do you fault-find an oily water separator that keeps alarming?

Treat a 15 ppm alarm as the equipment doing its job: let the three-way valve recirculate, stop, find the cause, and record what happened. Never adjust the monitor or the valve to make the alarm go away. These walk-throughs show the order.

Walk-through 1: 15 ppm alarm keeps operating during processing

Symptom. The bilge alarm activates soon after start-up; the automatic stopping device or three-way valve returns the effluent to the bilge or sludge side.

Checks in order.

  1. What are you processing? Bilge water with detergents, chemicals or emulsified oil from a recent tank cleaning or purifier upset will not separate by gravity. Stop and let the bilge holding tank settle.
  2. Oil content at the separator: drain accumulated oil from the separator's oil collecting space; a full oil chamber sends oil to the outlet.
  3. Coalescer or filter elements: choked or saturated elements pass oil.
  4. Feed pump: a centrifugal pump shears oil into fine droplets; separators are normally fed by a low-shear positive displacement pump at a steady rate. Check the flow is not above the rated capacity.
  5. Bilge alarm cell: dirty measuring cell windows give high readings. Flush with clean water as the maker allows and run the clean water check.

Likely cause. Emulsified or chemically contaminated bilge, saturated coalescer, overfeeding, or a dirty measuring cell.

Action. Stop processing, let the holding tank settle, drain oil to the sludge tank, change elements, clean the cell. Restart on settled water.

Report. Oil Record Book entries for each operation (processing, transfer to sludge tank); note the alarm and repair in the maintenance system.

Examiner's note: The weak answer "clean the sensor and restart" ignores why the bilge water is dirty. The strong answer starts with the source of the bilge water and keeps detergents and chemicals out of the bilge.

Walk-through 2: PSC asks you to demonstrate the OWS

Symptom. A port State control officer asks to see the separator and bilge alarm work.

Checks in order.

  1. Before arrival, make sure the Oil Record Book entries agree with the sludge and bilge tank soundings and the IOPP Supplement.
  2. Show the bilge alarm's stored records (date, time, alarm status and operating status) and its calibration certificate[1][2].
  3. Run the separator on clean water or settled bilge water as the inspector asks; show that when the alarm activates, the stopping device acts.
  4. Be ready for the inspector to check that the alarm stops discharge if no representative sample reaches it, which some administrations test specifically[5].

Likely cause of a deficiency. ORB inconsistent with soundings, alarm records missing, calibration overdue, or evidence of bypass pipes or flanges.

Action. Correct defects before sailing; never improvise.

Report. Master and chief engineer; company.

Examiner's note: Panels at management level ask how you would detect a bypass on your own ship. The strong answer names spool pieces, flexible hoses, recent paint on overboard flanges and ORB figures that do not reconcile.

What makes an OWS answer strong rather than weak?

Strong answers link the equipment to MARPOL records. The table shows common contrasts.

Weak and strong answers on OWS questions
QuestionWeak answerStrong answer
Why a positive displacement feed pump?It is stronger.It shears oil less, so droplets stay large enough to separate by gravity.
Alarm at 15 ppm: what happens?The pump stops.The automatic stopping device stops discharge overboard (or the three-way valve recirculates), and the alarm records the event.
Can you discharge in a special area?Never.Machinery space bilge water may be discharged in special areas (except the Antarctic area) only en route, through 15 ppm equipment with alarm and automatic stopping, under Reg. 15.3; tankers' cargo area discharges are banned there.
What is checked by PSC?The certificate.ORB versus soundings, alarm records, calibration, IOPP Supplement, and signs of bypass.

What should you read to revise the OWS?

Use primary texts first, then a textbook for the machine.

  • MARPOL Consolidated Edition (IMO): Annex I Regs. 12, 13, 14, 15 and 17, and the Oil Record Book Part I format.
  • IMO resolution MEPC.107(49) and its amendment MEPC.285(70): specifications for the separator and the 15 ppm bilge alarm.
  • Reed's Vol. 8 General Engineering Knowledge for Marine Engineers: separator design and bilge systems.
  • Introduction to Marine Engineering by D.A. Taylor: pumping systems and pollution equipment.
  • Your ship's OWS maker manual and the company bilge management procedure.

Then test yourself on the MARPOL MCQ bank and the pumps and purifiers MCQ bank. Our books for MEO Class 4 list and the 30-day oral preparation plan show where this topic fits.

Oral practice

35 oral questions with model answers

Read the question, answer it out loud as if the examiner is across the table, then open the model answer and mark yourself honestly.

–0/35 done
  1. 1
    CoreMARPOL Annex I Reg. 15.2

    What is the oil content limit for discharging machinery space bilge water, and what other conditions apply?

    Model answer points
    • Ships of 400 GT and above: discharge only if all conditions are met.
    • The ship is proceeding en route.
    • The mixture is processed through oil filtering equipment meeting Reg. 14.
    • Oil content of the effluent without dilution does not exceed 15 ppm.
    • On oil tankers, the mixture does not come from cargo pump-room bilges and is not mixed with cargo oil residues.
    • Inside the Antarctic area no discharge of oil or oily mixture at all.
    The examiner may follow up with
    • What changes inside a special area?
    • Which ships need the automatic stopping device?
    How did you do?
  2. 2
    CoreMARPOL Annex I Reg. 14

    Which ships must carry oil filtering equipment, and which need the alarm and automatic stopping device?

    Model answer points
    • Ships of 400 GT and above: oil filtering equipment that keeps effluent at or below 15 ppm (Reg. 14.1, 14.6).
    • Ships of 10,000 GT and above: equipment with a 15 ppm alarm and an automatic device that stops discharge when 15 ppm cannot be kept (Reg. 14.2, 14.7).
    • Any ship discharging in a special area must use the Reg. 14.7 type equipment.
    • Equipment must be type approved to MEPC.107(49) if installed from 1 January 2005.
    The examiner may follow up with
    • What standard applied before 2005?
    • Where is the equipment recorded on the IOPP?
    How did you do?
  3. 3
    CoreMEPC.107(49)

    Explain how a bilge separator works.

    Model answer points
    • Mixture is fed slowly by a positive displacement pump to avoid emulsifying it.
    • First stage: gravity separation; oil, being lighter, rises; coalescing plates or packing make small droplets join into bigger ones.
    • Separated oil collects at the top; an interface probe opens a valve to drain it to the sludge or bilge oil tank.
    • Second stage: coalescing filter, absorbent elements or a membrane polish the water below 15 ppm.
    • Effluent passes the 15 ppm bilge alarm before the overboard valve; if it reads high, flow returns to the bilge tank.
    • Some units have a heater to lower oil viscosity and help separation.
    The examiner may follow up with
    • Why is heating useful?
    • What is Stokes' law telling you here?
    How did you do?
  4. 4
    Core

    Why is the OWS feed pump a positive displacement pump and not a centrifugal pump?

    Model answer points
    • A centrifugal impeller shears oil into very fine droplets.
    • Fine droplets rise very slowly and form a stable emulsion.
    • The separator then cannot get below 15 ppm.
    • Screw or piston pumps move the liquid gently at steady flow.
    • Some designs pull the liquid through the separator by suction for the same reason.
    The examiner may follow up with
    • What else causes emulsions in bilge water?
    How did you do?
  5. 5
    CoreMEPC.107(49) Part 2

    How does the 15 ppm bilge alarm measure oil content?

    Model answer points
    • A continuous sample from the separator outlet passes through a measuring cell.
    • Light is passed through the sample; oil droplets scatter and absorb it; the detectors convert this into ppm.
    • Response time must not exceed 5 seconds.
    • It alarms above 15 ppm and also if it fails, is warming up or loses power.
    • The alarm signal operates the automatic stopping device or three-way valve.
    The examiner may follow up with
    • What gives a false high reading?
    • How do you clean the cell?
    How did you do?
  6. 6
    CoreMARPOL Annex I Reg. 15; Reg. 17

    Walk me through pumping the bilge holding tank overboard through the OWS.

    Model answer points
    • Check permission and conditions: ship en route, not in the Antarctic area, company rules followed; tell the bridge and get the position.
    • Sound the bilge holding tank and sludge tank; check the separator is full of water and the alarm reads normal.
    • Line up the suction from the bilge holding tank, start the feed pump, let effluent recirculate until steady below 15 ppm.
    • Allow overboard discharge as the system permits; stay with the unit and monitor the ppm and oil drain.
    • Stop, flush with clean water per maker, close the overboard valve.
    • Record a Code D entry: quantity, start and stop times and positions, tank, signature.
    The examiner may follow up with
    • What if the bridge reports a sheen?
    • Who signs the page?
    How did you do?
  7. 7
    CoreMARPOL Annex I Reg. 12

    What is the difference between the bilge holding tank and the sludge tank?

    Model answer points
    • Bilge holding tank: collects oily bilge water for processing through the OWS.
    • Sludge tank: holds oil residues from purifiers, filters, drains and leakage.
    • Sludge may be disposed of by a reception facility, the incinerator, or burning in a boiler or other approved means; never through the OWS.
    • Sludge tank piping must have no direct overboard connection other than the standard discharge connection.
    • Sludge transfers are Code C entries; bilge water operations are Code D or E.
    The examiner may follow up with
    • Why is evaporating water from sludge allowed?
    • What is the standard discharge connection?
    How did you do?
  8. 8
    CoreMARPOL Annex I Reg. 17

    Which Oil Record Book entries would you make in a normal week at sea?

    Model answer points
    • Code C: weekly retention of oil residues (sludge tank soundings) and any sludge transfers or incineration.
    • Code D: each bilge water discharge through the OWS or transfer to the holding tank, as guidance requires.
    • Code H: any bunkering of fuel or bulk lube oil.
    • Code F: any failure of the OWS or alarm and its repair.
    • Each entry signed by the officer in charge; each completed page signed by the master.
    • Quantities must match soundings and the alarm memory.
    The examiner may follow up with
    • Where do you find guidance on entries?
    • What does Code I cover?
    How did you do?
  9. 9
    CoreMARPOL Annex I Reg. 1.11, Reg. 15.3

    Which are the MARPOL Annex I special areas, and what changes for bilge discharge inside them?

    Model answer points
    • Annex I special areas: Mediterranean, Baltic, Black Sea, Red Sea, Gulfs area, Gulf of Aden, Antarctic, North West European waters, Oman area of the Arabian Sea, Southern South African waters (the Red Sea, Gulf of Aden and Oman area special-area discharge rules have not yet taken effect, pending reception facilities).
    • Bilge discharge in them (except Antarctic) needs Reg. 14.7 equipment with alarm and automatic stop.
    • Antarctic: total ban on oil discharge.
    • Check the ship's position on the chart and in the passage plan before you start.
    The examiner may follow up with
    • Which special area has a total ban?
    • Where does the ship check its position before pumping?
    How did you do?
  10. 10
    CoreMEPC.107(49) para 4.2.10

    How is the 15 ppm bilge alarm protected against tampering?

    Model answer points
    • Any access beyond routine checks needs a seal to be broken.
    • The alarm must activate whenever clean water is used for cleaning or zeroing.
    • It records date, time, alarm status and separator operating status, stored for at least 18 months.
    • Many companies also seal the overboard valve and flanges and log seal numbers.
    • Calibration only by the maker or an authorised person.
    The examiner may follow up with
    • Who keeps the seal log?
    • What does an inspector compare the memory with?
    How did you do?
  11. 11
    DeeperMEPC.107(49) para 4.2.11 as amended by MEPC.285(70)

    How often must the 15 ppm bilge alarm be calibrated, and by whom?

    Model answer points
    • Accuracy checked by calibration and testing by the manufacturer or persons it authorises.
    • Interval not exceeding five years after commissioning, or the maker's shorter term.
    • Alternatively, replace the unit with a calibrated one.
    • Calibration certificate kept on board; validity checked at IOPP annual, intermediate and renewal surveys.
    • Onboard, only the maker's routine tests (for example zero check) are allowed.
    The examiner may follow up with
    • What happens if the certificate has expired at a PSC inspection?
    How did you do?
  12. 12
    Deeper

    The OWS is running and the 15 ppm alarm keeps sounding. How do you find the fault?

    Model answer points
    • Stop overboard discharge at once (automatic stop should already have acted) and recirculate.
    • Feed side: wrong tank or low level drawing oil or sludge; emulsion from detergents or chemicals; solids; air drawn in.
    • Separator: oil not draining (fouled probe or valve), plates or coalescer fouled, heater off, first stage full of oil.
    • Monitor: dirty measuring cell, air bubbles or solids in sample, blocked sample line, sample valve partly closed.
    • Test the monitor with clean water to see if the alarm itself is faulty.
    • Record a Code F entry if equipment failed; tell the chief engineer.
    The examiner may follow up with
    • How can you tell emulsion from a monitor fault?
    How did you do?
  13. 13
    Deeper

    What causes bilge water emulsions and how do you prevent them?

    Model answer points
    • Cleaning chemicals and detergents used in the engine room drained into the bilge.
    • Centrifugal pumps used to transfer bilge water.
    • Very fine oil from purifier leaks or high-pressure leaks.
    • Prevention: use bilge-friendly (quick-separating) cleaners, keep detergents and boiler chemicals out of bilges.
    • Let the holding tank settle, skim oil from the top to the sludge tank.
    • Keep separate collection for clean and oily drains where the ship allows.
    The examiner may follow up with
    • What is an integrated bilge water treatment system?
    How did you do?
  14. 14
    Deeper

    What routine maintenance does the OWS need?

    Model answer points
    • Clean the 15 ppm cell and sample line per maker.
    • Clean or renew coalescer and filter elements at the interval or differential pressure set by the maker.
    • Check and clean the oil level probe and oil drain valve.
    • Check pump wear, relief valve and suction filter.
    • Test the alarm and automatic stop function and record it.
    • Drain and clean the separator internals at dry dock or as planned.
    The examiner may follow up with
    • Where do you record maintenance?
    How did you do?
  15. 15
    DeeperMARPOL Annex I Reg. 7; Supplement Form A/B

    What information does the IOPP certificate hold about the OWS?

    Model answer points
    • The IOPP certificate is issued under Annex I; the Supplement (Form A for ships other than tankers, Form B for tankers) lists the equipment.
    • It records the type of oil filtering equipment and whether it has the alarm and automatic stop.
    • It records sludge tank capacity, standard discharge connection and means of sludge disposal.
    • Surveyors check the equipment and the alarm calibration certificate at annual, intermediate and renewal surveys.
    The examiner may follow up with
    • What is the validity of the IOPP?
    How did you do?
  16. 16
    DeeperMARPOL Annex I Reg. 13

    What is the standard discharge connection and what is it used for?

    Model answer points
    • A flange of standard dimensions so any shore reception facility hose can connect.
    • Used to land sludge and oily bilge water to reception facilities.
    • Sludge tank discharge must go here; there must be no direct overboard line from the sludge tank.
    • Each landing is recorded (Code C for sludge, Code D for bilge water) and the receipt kept.
    The examiner may follow up with
    • What document do you get from the reception facility?
    How did you do?
  17. 17
    Deeper

    How do you test that the automatic stopping device works?

    Model answer points
    • Follow the maker's test procedure and the company PMS.
    • With the unit recirculating, simulate a high reading (maker's test function) or open the clean water flushing line, which must trigger the alarm.
    • Check the three-way valve or overboard valve moves to the recirculate or closed position.
    • Check the alarm is logged in the alarm memory.
    • Record the test in the PMS; not in the ORB unless guidance requires.
    The examiner may follow up with
    • Why should the system fail safe on power loss?
    How did you do?
  18. 18
    DeeperMARPOL Annex I Reg. 15.2.3

    What does 'without dilution' mean in the 15 ppm rule?

    Model answer points
    • The 15 ppm must be measured on the effluent as it leaves the separator.
    • You may not add seawater or fresh water to bring the reading down.
    • Dilution is a breach of MARPOL even if the reading is under 15 ppm.
    • The alarm is built to alarm whenever clean water reaches it, to show any such attempt.
    The examiner may follow up with
    • Can sea water be used to flush the separator?
    How did you do?
  19. 19
    DeeperMARPOL Annex I Reg. 15; SOPEP

    The bridge reports an oil sheen astern while you are pumping. What do you do?

    Model answer points
    • Stop the OWS and close the overboard valve at once.
    • Inform the chief engineer and bridge; check if the sheen comes from the OWS, another overboard, a leaking stern tube or another ship.
    • Check the alarm memory and the OWS for faults; sound tanks.
    • If oil escaped, follow the SOPEP: master reports to coastal State as required.
    • Record in the ORB: Code G for an accidental discharge, Code F for equipment failure.
    • Do not restart until the cause is found.
    The examiner may follow up with
    • Who reports to the coastal State?
    • What is the SOPEP?
    How did you do?
  20. 20
    DeeperMARPOL Annex I Reg. 12

    How do you dispose of sludge on board?

    Model answer points
    • Land it to a reception facility through the standard discharge connection.
    • Burn it in an approved incinerator or in a boiler designed for it.
    • Evaporate water from the sludge tank by heating, as allowed by guidance, and record it.
    • Mix with fuel only where the system is designed and approved for it.
    • Every operation is a Code C entry with quantities and tank soundings.
    The examiner may follow up with
    • Why must incinerator use be within its certified limits?
    How did you do?
  21. 21
    Deeper

    What does a port State control officer look for on the OWS during an inspection?

    Model answer points
    • Asks an engineer to run it and test the alarm and automatic stop.
    • Checks the calibration certificate and the alarm memory against ORB Code D entries.
    • Compares sludge and bilge quantities with fuel used and running hours.
    • Looks for fresh paint on flanges, loose spool pieces, hoses or blanks, and clean pipes that should be oily.
    • Interviews engine crew on how and when the OWS is used.
    • Any doubt can lead to a more detailed inspection and detention.
    The examiner may follow up with
    • What do you do if an inspector finds a defect?
    How did you do?
  22. 22
    DeeperMARPOL Annex I Reg. 15.2.4

    Can bilge water from the cargo pump room of a tanker go through the engine room OWS?

    Model answer points
    • No. Reg. 15 does not allow discharge of cargo pump-room bilges through the machinery space route.
    • Pump-room bilges go to the slop tank and are handled under the cargo rules (Reg. 34) or landed ashore.
    • Mixing with cargo residues is also excluded.
    • Records for cargo-related operations go in ORB Part II.
    The examiner may follow up with
    • What is in ORB Part II?
    How did you do?
  23. 23
    DeeperISM Code section 10; MARPOL Annex I Reg. 17

    What are the chief engineer's responsibilities for the bilge system and OWS?

    Model answer points
    • Set standing orders: who may operate the OWS, when and where.
    • Control seals, keys and spare parts for the overboard line and alarm.
    • Make sure the ORB is correct, checked against soundings, and signed.
    • Plan maintenance and keep the alarm calibration in date.
    • Train junior engineers and create a culture where anyone can report a bypass.
    • Report defects to the company and flag/class when equipment cannot be repaired.
    The examiner may follow up with
    • What would you do if a junior reports a bypass to you?
    How did you do?
  24. 24
    DeeperMARPOL Annex I Reg. 14; Reg. 17

    Can a ship with a broken OWS sail, and what must be done?

    Model answer points
    • The ship must not discharge bilge water overboard until the equipment is repaired.
    • Keep all bilge water on board and land it to a reception facility.
    • Record the failure as Code F, with date and time, and the repair when done.
    • Inform the company; flag State and class are informed as the company procedure and flag require.
    • PSC may require repair before sailing if the ship cannot hold its bilge water safely.
    The examiner may follow up with
    • How long can you go without discharging?
    How did you do?
  25. 25
    DeeperMARPOL Annex I Reg. 31; MEPC.108(49)

    What is an oil content meter and how is it different from the 15 ppm bilge alarm?

    Model answer points
    • The oil discharge monitoring equipment (ODME) is used on tankers for discharge of cargo slops and dirty ballast.
    • It measures oil content and flow and calculates litres per nautical mile and total quantity.
    • The 15 ppm bilge alarm only checks machinery space bilge effluent against 15 ppm.
    • ODME records go in ORB Part II; bilge alarm records relate to ORB Part I.
    The examiner may follow up with
    • What standard covers the ODME?
    How did you do?
  26. 26
    Deeper

    Explain Stokes' law and how it applies to the OWS.

    Model answer points
    • Stokes' law gives the rising (or settling) speed of a droplet: it is proportional to the square of the droplet diameter and to the density difference between oil and water, and inversely proportional to the water's viscosity.
    • So big droplets rise much faster: doubling the diameter gives four times the speed. That is why the OWS uses coalescing plates and why the feed must not be sheared by a centrifugal pump.
    • A larger density difference helps: heavy fuel close to water density separates poorly in a gravity unit.
    • Heating lowers viscosity and helps separation, within the maker's limits.
    • A purifier uses the same law but replaces gravity (g) with centrifugal acceleration thousands of times larger.
    • Emulsions fail because the droplets are too small to rise in the time the water spends in the separator.
    The examiner may follow up with
    • Why does a purifier separate better than a settling tank?
    • Which term in Stokes' law does a coalescer change?
    How did you do?
  27. 27
    Deeper

    What is the correct way to correct a wrong Oil Record Book entry?

    Model answer points
    • Never erase, tear out or overwrite.
    • Strike through the wrong entry with a single line so it stays readable.
    • Write the correct entry and sign and date the correction.
    • For electronic record books, the system keeps an audit trail of changes.
    • Follow the ORB guidance and company procedure.
    The examiner may follow up with
    • Who countersigns ORB pages?
    • How long is the ORB kept on board?
    How did you do?
  28. 28
    TrapMARPOL Annex I Reg. 15; ISM Code

    A rating tells you the second engineer has fitted a spool piece from the bilge line to the overboard. What do you do?

    Model answer points
    • Do not use the line and do not take part.
    • Report to the chief engineer and master at once; if they are involved, use the company's designated person ashore (DPA).
    • Do not destroy evidence; the line must be removed under control and recorded.
    • Make sure no false entry is written in the ORB.
    • The company must investigate under its SMS and inform the flag as required.
    • Protect the rating who reported it.
    The examiner may follow up with
    • Who is the DPA?
    • What are the consequences for the officers?
    How did you do?
  29. 29
    TrapMARPOL Annex I Reg. 15.2.3; MEPC.107(49) para 4.2.10

    The alarm reads 20 ppm. A senior engineer says: open the fresh water line, the reading will drop and you can carry on. Is that acceptable?

    Model answer points
    • No. That is dilution and is illegal.
    • The alarm is designed to alarm when clean water is used, and it records that event with date and time.
    • Stop the discharge and find the cause (emulsion, fouled separator, wrong tank).
    • Record the stop and any equipment failure.
    • Refuse politely and report if pressed.
    The examiner may follow up with
    • What does the alarm memory record when clean water is used?
    How did you do?
  30. 30
    TrapMARPOL Annex I Reg. 15.2.1

    Can you discharge bilge water through the OWS while the ship is at anchor?

    Model answer points
    • No. The ship must be proceeding en route.
    • At anchor, alongside or drifting the ship is not en route.
    • Keep the bilge water in the holding tank or land it.
    • Many company procedures also ban discharge near the coast, even when en route.
    The examiner may follow up with
    • Is drifting en route?
    How did you do?
  31. 31
    TrapMARPOL Annex I Reg. 15.4

    Is the ship allowed to discharge 15 ppm bilge water in the Antarctic if the equipment is working perfectly?

    Model answer points
    • No. In the Antarctic area any discharge of oil or oily mixture from any ship is prohibited.
    • The 15 ppm route does not apply there.
    • Hold all bilge water on board and land it.
    • Also note the separate Polar Code restrictions on the ship.
    The examiner may follow up with
    • Where is the Antarctic area boundary?
    How did you do?
  32. 32
    TrapMEPC.285(70)

    Can you calibrate the 15 ppm alarm yourself on board if you have the test kit?

    Model answer points
    • No. Calibration is by the manufacturer or a person the manufacturer authorises.
    • On board you may only do the maker's routine checks, such as zero and function tests.
    • Breaking the seal to adjust it is a red flag at inspection.
    • If it is out of calibration, replace with a calibrated unit or call the maker's service.
    The examiner may follow up with
    • What onboard checks are you allowed to make on the alarm?
    How did you do?
  33. 33
    TrapMARPOL Annex I Reg. 15.3

    Can a 3,000 GT ship without an alarm and automatic stop pump bilges in the Mediterranean?

    Model answer points
    • No. Inside a special area the equipment must meet Reg. 14.7, which includes the 15 ppm alarm and automatic stopping device.
    • The 10,000 GT threshold in Reg. 14.2 applies to fitting; Reg. 15.3 adds the condition for discharge in special areas.
    • In practice most ships carry the alarm and automatic stop anyway.
    • Check the IOPP Supplement: it shows whether the ship has Reg. 14.7 equipment.
    The examiner may follow up with
    • What does Reg. 14.7 equipment include?
    How did you do?
  34. 34
    TrapMARPOL Annex I Reg. 12.3

    Is it acceptable to transfer sludge to the bilge holding tank to be processed through the OWS?

    Model answer points
    • No. Sludge must be kept in the sludge tank and disposed of by approved means.
    • Moving sludge into the bilge system to 'process' it is treated as an attempt at illegal discharge.
    • Sludge tank piping must have no connection to the bilge system, bilge holding tank, tank top or OWS. The only exceptions are a drain with a manually operated self-closing valve (for settled water, to the bilge holding tank or bilge well) and a common line to the standard discharge connection.
    • Inspectors check these lines for unauthorised connections.
    The examiner may follow up with
    • Where do you record sludge transfers?
    How did you do?
  35. 35
    Trap

    The 15 ppm alarm shows 0 ppm even when you pump oily water. What does that tell you?

    Model answer points
    • The monitor is faulty or not getting a sample, not that the separator is perfect.
    • Check the sample line and valve are open and the sample pump or flow is working.
    • Check the cell is not blocked and the instrument is powered and not in test mode.
    • Stop overboard discharge until it is proved to work.
    • Record the failure (Code F) and repair; a blocked sample line is a common PSC finding.
    The examiner may follow up with
    • What is a common PSC finding on bilge alarm sample lines?
    How did you do?

Reading answers is not the same as saying them. Our AI voice examiner asks these out loud, listens to your answer, asks the follow-up and marks you against the rule. Join early access or try the free timed mock oral drill.

Frequently asked questions

What is the oil content limit for discharging bilge water?

15 parts per million, measured without dilution, through approved oil filtering equipment while the ship is en route. Tanker cargo pump-room bilges can never go through this route, and nothing may be discharged in the Antarctic area.

Which ships need an oily water separator?

Under MARPOL Annex I Reg. 14, ships of 400 GT and above need oil filtering equipment. Ships of 10,000 GT and above also need the 15 ppm alarm with automatic stopping, and any ship discharging inside a special area needs that equipment too.

Can you discharge bilge water in a special area?

Yes, in the special areas other than the Antarctic, if the ship is en route, the water passes through equipment with a 15 ppm alarm and automatic stop, and the effluent is 15 ppm or less. Many companies forbid it anyway as a matter of policy.

How long must the 15 ppm bilge alarm store its records?

MEPC.107(49) requires at least 18 months of recorded date, time, alarm status and separator operating status. If the alarm is replaced, the old data must still be available on board for 18 months.

Who can calibrate the 15 ppm bilge alarm?

Only the manufacturer or a person authorised by the manufacturer. Under MEPC.285(70) this is done at intervals not exceeding five years from commissioning, or the maker's shorter term, and the certificate stays on board.

Why must the bilge alarm sound when clean water is used?

To stop anyone hiding a high reading by flushing the sensor with fresh water while oily water goes overboard. MEPC.107(49) requires the alarm to be built so it always alarms when clean water is used for cleaning or zeroing.

What is the difference between bilge water and sludge?

Bilge water is the oily water that collects in machinery space bilges and may be processed through the OWS. Sludge is the oil residue from purifiers, filters and leaks; it must be kept in the sludge tank and burned, incinerated or landed ashore, never discharged through the OWS.

Which Oil Record Book code is used for pumping bilges through the OWS?

Code D, for non-automatic discharge overboard of bilge water. Code E is for automatic discharge, Code C for sludge, and Code F for the condition of the filtering equipment.

Why is a positive displacement pump used to feed the OWS?

It moves the mixture slowly without shearing it. A centrifugal pump breaks oil into very small droplets and makes an emulsion that the separator cannot split, so the effluent goes above 15 ppm.

What happens if a magic pipe is found during an inspection?

The ship can be detained, and the engineers and company can face criminal prosecution, heavy fines and loss of certificates. The Oil Record Book entries made to hide it are treated as false records, which is a separate offence in many countries.

How long must the Oil Record Book be kept?

MARPOL Annex I Reg. 17 requires it to be kept on board, readily available, for three years after the last entry. Electronic record books are allowed if approved by the flag State.

Is the OWS asked in the MCA EOOW oral?

Yes, usually as a scenario: the alarm sounds while you are pumping, or the bridge reports an oil sheen astern. The examiner wants to hear that you stop, investigate, inform the chief engineer and record it correctly.

Sources 5 documents

Each number in the text links to the source below. Labels show the type of source; see our editorial policy.

  1. Official IMO Resolution MEPC.107(49), Revised guidelines and specifications for pollution prevention equipment for machinery space bilges of ships, paras 4.2.6-4.2.10 · 18 July 2003
  2. Official IMO Resolution MEPC.285(70), Amendments to MEPC.107(49) para 4.2.11 · 28 October 2016
  3. Official IMO: Special Areas under MARPOL
  4. Reported DNV, MARPOL Electronic record books - option available from 1 October 2020 · 1 January 2020
  5. Reported Steamship Mutual: Testing and inspection of oil filtering equipment - AMSA Marine Notice 03/2024 · 4 July 2024

Where should you go next?

  • Oral topics14 pages: examiner questions with model answer points, deck and engine
  • Question banks7 pages: free MCQ sets with answers and explanations
  • CoC exam guides16 pages: every oral and written exam, authority by authority
  • Free tools4 pages: mock oral drill, lights trainer, sea-time calculator, practice tests
Exam Prep DeskMaritime exam researchers

We write from the conventions (STCW, COLREG, SOLAS, MARPOL), the authorities' own notices and published syllabi, and cite the source for every fee, rule and date. We are independent and not linked to any maritime administration or test provider. Found an error? It matters at sea: tell us and see how we correct · Disclaimer.

Related guides

AI voice mock oral

Say it out loud before the examiner asks.

Our examiner asks CoC oral questions by rank and function, listens to your answer, asks the follow-up and scores you against the rule. Early access is open for India first.

  • Deck and engine, every rank
  • Answers referenced to the conventions
  • Independent, not linked to any authority
WhatsApp us