NautemyCoC orals · exams · job testsEarly access
Oral topic39 min readJump to 38 questions

Two-stroke main engine oral questions and model answers for MEO and MCA engineers

Examiners use the slow-speed two-stroke main engine to test whether you can run it, find faults and handle emergencies. Know scavenge fire and crankcase explosion actions, relief valve and oil mist detector rules, starting air safety and crankshaft deflections.

On this page
  1. Key facts
  2. What do examiners ask about the two-stroke main engine at each rank?
  3. How does a two-stroke crosshead engine work?
  4. Which main engine safety rules and numbers must you know?
  5. How should you structure a main engine answer in the oral?
  6. What do you do in a scavenge fire?
  7. What causes a crankcase explosion and how do you prevent it?
  8. What mistakes do candidates make on the main engine?
  9. Which main engine scenarios do examiners give you?
  10. Which main engine measurements do you need to explain?
  11. How do you fault-find a two-stroke main engine problem in the oral?
  12. What does a strong main engine answer sound like compared with a weak one?
  13. What should you read to revise the main engine?
  14. How can you practise main engine questions before the exam?
  15. 38 practice questions
  16. Frequently asked questions
  17. Sources

Key facts

Examined at
MEO Class 4, 2 and 1 (India); MCA EOOW, Second and Chief Engineer (UK)
STCW function
Marine engineering, operational and management level[1]
Crankcase relief valves needed
Bore 200 mm and above, or crankcase 0.6 m³ and above[2]
Relief valve fully open
Not more than 0.2 bar[3]
Relief area
At least 115 cm² per m³ of crankcase volume[3]
Oil mist detection
Engines of 2,250 kW and above or bore over 300 mm[4]
Overspeed limit
Governor 115%; separate trip 120% where fitted[5]
Key regulations
SOLAS Ch. II-1 Regs. 27, 31; IACS UR M3, M9, M10, M35

Checked 13 November 2026. Fees and rules change: confirm with the authority before you book.

What do examiners ask about the two-stroke main engine at each rank?

Every engine oral spends time on the main engine, but the depth changes with rank. At operational level you must run it, watch it and react to alarms; at management level you must plan overhauls, judge wear and make decisions the chief engineer signs.

The operational level in the STCW Code covers the officer in charge of an engineering watch and the designated duty engineer of an unmanned engine room[6]. That is the MEO Class 4 oral in India and the MCA EOOW oral in the UK. Second and chief engineer are management level[6]: the MEO Class 2 oral, MEO Class 1 oral, MCA Second Engineer oral and MCA Chief Engineer oral. In the UK the engineering oral syllabus is MIN 654[7], and the EOOW oral is built around routine, non-routine and contingency scenarios[7]. Expect the same scenario style in India.

How main engine depth changes with rank
Rank / examTypical depthQuestions to expect
India MEO Class 4Working cycle, systems, watchkeeping checks, alarms, first actions in emergenciesDraw the uniflow scavenge cycle. What do you check before starting? Scavenge fire: first actions?
India MEO Class 2Fault-finding, overhaul procedures, measurements, safety devices and their purposeWalk me through a piston overhaul. How do you take crankshaft deflections and what do the readings tell you?
India MEO Class 1Decisions, risk, class and flag, performance, fuel and lube strategy, company reportingCrankcase explosion happened: what do you report and to whom, and when do you restart? How do you set cylinder oil feed rate on low-sulphur fuel?
MCA EOOWScenario-based watchkeeping on ships of 750 kW or moreYou are alone on watch and the oil mist detector alarms. Talk me through it.
MCA Second EngineerMaintenance planning, measurements, root cause, permit to workLiner wear is high on one unit. What could cause it and how would you prove it?
MCA Chief EngineerManagement, legal and class matters, performance analysisThe engine must run with one unit cut out. How do you decide, who do you tell, what limits apply?

How does a two-stroke crosshead engine work?

A modern slow-speed main engine is a two-stroke, single-acting, crosshead, uniflow-scavenged diesel with one exhaust valve per cylinder and a turbocharger. It completes the cycle in one revolution: scavenge air enters through ports at the bottom of the liner and leaves with the exhaust through the valve in the cover.

Examiners often ask you to sketch the timing diagram and explain why each feature exists. The crosshead lets the piston rod move in a straight line, so the stuffing box can seal the crankcase from the scavenge space. That keeps dirty, acidic scavenge drainage out of the system oil and lets you use separate cylinder oil and system oil. Learn the main components and their purpose, then learn how the starting air system and the auxiliary blowers fit around them.

Main parts and why they matter in the oral
PartPurposeWhat examiners probe
Scavenge ports and air boxAdmit charge air and sweep out exhaustPort inspection: ring condition, liner surface, deposits, scavenge fire risk
Exhaust valve (hydraulically opened, air spring closed)Uniflow exhaust; timing controls compressionValve not closing, burnt seat, air spring pressure loss
Piston rod stuffing boxSeals crankcase from scavenge space; scrapes oilDrain oil analysis, leak-off, system oil contamination
Crosshead and guidesConverts straight-line rod motion to connecting rod swingCrosshead bearing loading, lubrication pressure
Main and crankpin bearingsCarry the crankshaft and connecting rodClearances, hot spots, oil mist, deflections
Turbocharger and air coolerRaise charge air densitySurging, fouling, water mist catcher drains
Auxiliary blowersSupply air at low load when the turbocharger cannotAuto start and stop on scavenge pressure; interlock with starting
Tie rods, bedplate, chocks, holding-down boltsKeep the structure in compression and alignedTie-rod tension checks, chock fretting, loose bolts
Thrust blockTransfers propeller thrust to the hullThrust pad temperature, axial clearance

Which main engine safety rules and numbers must you know?

The numbers examiners expect are the ones written in SOLAS and the IACS unified requirements, not maker settings. Learn the thresholds for crankcase relief valves, oil mist detection and overspeed, and say clearly which rule they come from.

SOLAS requires crankcase explosion relief valves on engines with a bore of 200 mm or more or a crankcase volume of 0.6 m³ or more, arranged so the discharge does not injure people[2]. IACS UR M9 adds the details: number of valves, minimum area and opening pressure[3]. UR M10 covers oil mist detection, scavenge space relief valves and the warning notice on the crankcase doors[4]. UR M3 covers governors and overspeed[5], and UR M35 lists the alarms and slowdowns for engines in unattended machinery spaces[8]. For starting air, SOLAS requires a limit on automatic repeated start attempts and a low starting air pressure alarm[9]. Maker values such as jacket water temperature, lube oil pressure or exhaust temperatures vary by engine. Quote the range from your own ship's manual and say that it is maker-specific.

Main engine rules to quote
ItemRequirementSource
Crankcase relief valves fittedBore 200 mm and above, or crankcase gross volume 0.6 m³ and aboveSOLAS Ch. II-1 Reg. 27; IACS UR M9.1
Number of relief valvesBore up to 250 mm: one near each end (plus middle if more than 8 throws); over 250 to 300 mm: every alternate throw, minimum two; over 300 mm: every main throwIACS UR M9.1
Relief valve areaEach at least 45 cm²; total at least 115 cm² per m³ of crankcase gross volumeIACS UR M9.2, M9.3
Relief valve openingQuick-acting, self-closing, fully open at not more than 0.2 bar, flame arrester fittedIACS UR M9.4 to M9.7
Oil mist detectionEngines of 2,250 kW and above or bore over 300 mm; low-speed engines alarm and slowdownIACS UR M10; SOLAS Ch. II-1 Part E
Scavenge spacesExplosion relief valves where open to the cylindersIACS UR M10
Crankcase door noticeDo not open until the engine has cooled after suspected overheatingIACS UR M10
GovernorSpeed cannot exceed rated by more than 15%IACS UR M3.1.1
Separate overspeed trip120% of rated for engines of 220 kW and above that can be declutched or drive a CP propellerIACS UR M3.1.2
Starting airLimit on automatic start attempts; low pressure alarm on bridge and in engine roomSOLAS Ch. II-1 Reg. 31

How should you structure a main engine answer in the oral?

Answer in the order an examiner marks: safety first, then the immediate action, then the cause, then the follow-up. For a description question, give purpose, construction, operation and checks, in that order.

A good pattern for any emergency is: recognise (which alarm, what you see), inform (bridge and chief engineer), act (reduce load, isolate, stop when the bridge agrees), protect people (keep clear of relief valves and doors), investigate (only after cooling and with a permit) and record (log book, report to company and class where needed). For a procedure, use steps you would really follow on board: isolation, permit, tools, measurements, limits from the manual, box-up and trial. Examiners stop candidates who start opening doors or pulling units before they have made the engine safe. Practise saying it out loud in the mock oral drill; written knowledge alone does not show up well under questioning.

What do you do in a scavenge fire?

A scavenge fire is a fire of oil and carbon residue in the scavenge air space, usually started by blow-by of hot gas past worn or stuck piston rings. Reduce speed, cut fuel to the affected unit, increase cylinder lubrication on it, and stop the engine and use the fixed system if it spreads.

Signs are high scavenge air temperature at one unit (the UR M35 list includes a scavenge box fire alarm[8]), high exhaust temperature on that cylinder, loss of power, sparks or smoke from the scavenge drains and, in bad cases, hot paint on the scavenge doors. The exact sequence and extinguishing medium (CO2, steam or dry powder) are in the engine maker's instructions, so quote those for your engine. The steps below are the generic order examiners expect.

  1. 1
    Inform

    Tell the bridge and call the chief engineer. Ask the bridge to reduce speed; the engine should go to slow or dead slow as the maker requires.

  2. 2
    Starve the fire of fuel

    Cut off fuel to the affected cylinder (fuel pump lifted or the electronic unit cut out) and increase cylinder oil feed to that unit to protect the liner and rings.

  3. 3
    Close drains and watch

    Close scavenge drain cocks so sparks are not blown into the engine room. Keep everyone clear of scavenge doors and relief valves. Monitor scavenge temperatures on adjacent units.

  4. 4
    Stop if it spreads

    If the fire does not die out or spreads to other units, stop the engine with the bridge's agreement, stop the auxiliary blowers, engage turning gear and use the fixed scavenge fire extinguishing system.

  5. 5
    Cool before opening

    Do not open the scavenge doors until the fire is out and the space has cooled; fresh air can re-ignite deposits. Opening early can cause an explosion.

  6. 6
    Inspect and repair

    Inspect liners, rings, piston rod, stuffing box, air box and scavenge relief valves. Clean the space. Find and remove the cause before restarting under observation.

  7. 7
    Record and report

    Log times, positions and actions. Report to the company; class may need to be informed if there is damage.

What causes a crankcase explosion and how do you prevent it?

A crankcase explosion needs oil mist in the explosive range and an ignition source. A hot spot (bearing, crosshead, piston rod rubbing, chain drive) vaporises oil, the vapour condenses into a fine mist, and the hot spot ignites it. The first explosion can be followed by a stronger secondary one when air rushes in.

Prevention is about the hot spot and the protection. Monitor oil mist[4], bearing temperatures and splash oil temperatures; keep lube oil clean and at the right pressure and temperature; keep water out. Relief valves limit the pressure rise, close again to stop air entering and carry flame arresters to stop flame reaching the engine room[3]. Crankcase doors must be strong enough and fastened well enough not to blow off, and lube oil drain pipes end below the oil level so the explosion cannot travel into the sump tank[4]. The main fire risk is to the people standing next to the engine, which is why examiners care about your first actions.

Crankcase protection devices
DeviceWhat it doesCommon oral trap
Oil mist detector (OMD)Samples each crankcase compartment and alarms at a set mist density; low-speed engines slow downIt alarms on mist, not on temperature; a sensor fault can mask a real alarm
Bearing temperature monitoringAlternative or addition to OMD under UR M10Main bearing sensors may not see crankpin or crosshead hot spots
Crankcase relief valvesRelieve the first pressure rise and closeThey do not prevent the explosion; they limit damage
Flame arrester on relief valveStops the flame leaving the crankcaseOil-soaked or painted arresters lose effect
Warning notice on doorsDo not open until cooledOpening early admits air and can cause the secondary explosion
Submerged drain pipe endsStop flame travel to the sump tankOften forgotten in the answer

What mistakes do candidates make on the main engine?

The most common failure is jumping to repairs before making the engine and the people safe. Examiners also mark down candidates who quote one ship's settings as rules, or who cannot explain what a reading means.

  • Opening the crankcase after an oil mist alarm. The UR M10 warning notice exists because people have been killed doing this. Say you stop, wait for cooling and keep clear of the relief valves.
  • Saying the relief valve prevents the explosion. It only limits the pressure and closes to stop air inrush.
  • Mixing up slowdown and shutdown. Low-speed main engines slow down on oil mist; medium-speed generator engines shut down[4]. Look at the auxiliary diesel engine topic for the difference.
  • Quoting maker numbers as law. Jacket water outlet temperatures, lube oil pressures and deflection limits come from the maker's manual.
  • Ignoring the bridge. The main engine belongs to the ship's safety. Always ask for or inform about speed changes.
  • No cause. For every emergency, give at least two likely causes and how you would confirm them.
  • Forgetting records. Logbook, maintenance system, class report and, for fuel matters, the sulphur records.

More on how candidates lose marks: why seafarers fail oral exams and what oral examiners look for.

Which main engine scenarios do examiners give you?

Scenario questions start simple and get worse: an alarm, then a second fault, then a time pressure such as a narrow channel. Practise each one aloud, with the bridge in the story.

Scenario What a strong answer covers
Oil mist alarm at sea, engine slowed down automatically Inform bridge and chief, check if the alarm is real (trend, all sensors, smell, temperatures), stop when safe, do not open doors until cool, find the hot spot
One exhaust temperature rising, others normal Fuel valve, exhaust valve leaking, scavenge fire start, blow-by, fuel pump problem; check scavenge temperature and indicator diagram
Engine fails to start on air from the bridge Starting air pressure, main start valve, distributor, turning gear interlock, slow-turning, fuel limiter, control air; change to local control
Turbocharger surging Fouled nozzle ring or air cooler, damaged blades, sudden load change, scavenge port blockage, exhaust valve faults; reduce load, clean, inspect
Engine overspeed in heavy weather Governor and overspeed trip behaviour, propeller racing, ask bridge to reduce speed and change course
Main engine must run with one unit cut out Maker's guidance, barred speed range changes, reduced load limits, inform bridge, class and company

For starting problems see the air compressors and starting air topic. For the alarm and slowdown philosophy see UMS and automation. For fire fighting in the engine room see the fire-fighting topic.

Which main engine measurements do you need to explain?

At Class 2 and above you must explain how each measurement is taken, what affects it and what a bad reading means. You do not need to remember maker limits, but you must say where you would find them and what you would do if a reading was out.

Measurement How it is taken What it tells you
Crankshaft deflection Dial gauge between webs, readings at set crank positions, engine at stated temperature and loading condition Bearing alignment and wear, hull deflection, chocking; compare with previous readings and the maker's limits
Main bearing clearance Feeler gauge or bridge gauge with the top shell in place, or lift method per maker Wear of white metal; compare with deflections
Liner wear Internal micrometer at set heights and in two directions (fore-aft, port-stbd) Wear rate per 1,000 running hours, ovality, cylinder oil and fuel quality effects
Piston ring clearances Ring groove (axial) clearance and butt gap in a gauge ring Ring wear, groove wear, collapse risk
Indicator diagrams / cylinder pressure Electronic pressure measuring of Pmax and Pcomp Injection timing, compression loss, fuel valve faults, load balance
Tie-rod tension Hydraulic jack to the maker's pressure Structural integrity of the frame
Bearing temperatures and OMD trend Continuous monitoring Early warning of hot spots

Revise these with the main engine MCQ bank and the MEO Class 4 vs Class 2 comparison, which shows how the depth changes.

How do you fault-find a two-stroke main engine problem in the oral?

Work from symptom to cause in a fixed order: make the plant safe, tell the bridge, check the cheapest and most likely causes first, and only then open anything up. The three walk-throughs below are the kind examiners give at MEO Class 4 and MEO Class 2 level.

Walk-through 1: exhaust temperature high on one cylinder

Symptom. At sea on steady load, one unit's exhaust outlet temperature has risen well above the others and keeps rising. Scavenge and turbocharger readings are normal.

Checks in order.

  1. Compare with the trend, not just the other units. A slow rise over days points to fouling or wear; a sudden rise points to a fault such as a stuck injector or a burnt valve.
  2. Check the thermocouple and its reading against the cylinder's other indications (cooling water outlet, piston cooling outlet). A faulty sensor is common and costs nothing to rule out.
  3. Check the fuel pump index for that unit. A higher index than the others means the unit is taking more fuel to give its share of power.
  4. Take an indicator card or read the cylinder pressure monitoring: compare Pcomp and Pmax with the other units (see fuel injection and governors for what each pattern means).
  5. Listen at the scavenge drain and check its temperature. Blow-by past the rings heats the scavenge space and starts scavenge fires.
  6. If the unit has an exhaust valve with hydraulic actuation, check its timing and closing indication.

Likely cause. Normal Pcomp with low Pmax and late, smoky combustion points to a dribbling or worn injector, or fuel pump timing. Low Pcomp and low Pmax together point to blow-by (broken or stuck rings, worn liner) or an exhaust valve that does not seat.

Action. Ask the bridge for a load reduction if the temperature is near the alarm and slowdown point. Change the injector (normally a quick job with the engine stopped, done at a convenient time agreed with the bridge). If the problem is blow-by, inspect through the scavenge ports at the next stop. Do not simply cut the fuel to that unit to bring the number down; that hides the cause and unbalances the engine.

Report. Inform the chief engineer, log the readings and the action, and record the injector change or port inspection findings in the maintenance system.

Examiner's note: The weak answer is "reduce the fuel on that unit". Panels want to hear you separate a sensor fault, a combustion fault and a sealing fault using readings you already have, before you stop the engine.

Walk-through 2: the engine does not start on air

Symptom. On a start order from the bridge the engine turns over slowly or not at all, or turns but does not fire.

Checks in order.

  1. Starting air pressure in the receivers and the main starting valve open. Low air is the most common cause on arrival after a long sea passage (see air compressors and starting air).
  2. Turning gear disengaged and its interlock made. Control air pressure available. Any "start blocked" alarm on the control system.
  3. If the engine turns but does not fire: fuel index, fuel pressure and temperature at the engine inlet, and whether the fuel is at the right viscosity after a changeover.
  4. If the engine does not turn at all with good air: the starting air distributor, the automatic starting valve, and a cylinder starting valve stuck closed.
  5. After repeated failed starts, stop and look before you waste the remaining air.

Likely cause. No turn with good air: control air, interlock or distributor fault. Turns but no firing: fuel supply, wrong viscosity or a governor or fuel limiter setting.

Action. Tell the bridge at once that the engine is not available and how long you expect to need, because this is a navigation emergency in confined waters. Fix the cause or change to local control.

Report. Log every start attempt and the cause, and inform the chief engineer.

Examiner's note: Candidates often keep trying to start. The strong answer tells the bridge first, counts the air left, and knows that the rules limit automatic repeated start attempts on remote control so that air is kept for local starting[9].

Walk-through 3: cooling water expansion tank level rising or gassing

Symptom. The jacket water expansion tank level rises, the water smells of exhaust, or the tank vents show bubbles. Jacket water pressure may fluctuate.

Checks in order.

  1. Isolate the obvious: is someone filling the system, or is the fresh water generator feed linked to it?
  2. Watch which unit's cooling outlet temperature fluctuates or which unit shows gas at its outlet test cock, where fitted.
  3. Check the cooling water for oil or high chloride; test for exhaust gas products (low pH).
  4. When the engine is stopped, pressure-test the cooling spaces and inspect the cylinder cover and liner for cracks.

Likely cause. Combustion gas entering the cooling water through a cracked cylinder cover, a cracked liner or a leaking cooling joint.

Action. Reduce load on the advice of the chief engineer, prepare to isolate that unit, and plan the change of cover or liner. Running with a cracked cover risks water entering the cylinder and a hydraulic lock on starting, so turn the engine on the turning gear with indicator cocks open before any start.

Report. Chief engineer, bridge (power reduction), company technical department.

Examiner's note: The trap is to treat this as a simple make-up job. The strong answer links gas in the cooling water to a cracked cover or liner and mentions the hydraulic lock risk.

What does a strong main engine answer sound like compared with a weak one?

A strong answer gives the safety point first, then the reason, then the steps in order, using the ship's own limits rather than invented numbers. The table compares typical answers.

Weak and strong answers on main engine questions
QuestionWeak answerStrong answer
Scavenge fire on one unit: what do you do?Stop the engine and put CO2 in.Inform bridge, reduce load, cut fuel to that unit, increase cylinder oil feed, keep the engine turning slowly if safe; only stop and use the fixed system if the fire spreads; inspect after cooling.
Why is the crosshead bearing hard to lubricate?Because it is heavily loaded.The load never reverses on a two-stroke crosshead and the oscillating motion is slow, so a hydrodynamic film is hard to form; hence high-pressure lube oil and careful bearing design.
How do you know the cylinder oil feed rate is right?Follow the chart.Set it from the maker's guidance for the fuel sulphur, then confirm by scavenge drain oil analysis (iron and remaining base number) and liner inspections.
Engine fails to start: first action?Try again.Tell the bridge, check air pressure, turning gear and control air, then diagnose before using more air.

What should you read to revise the main engine?

Read one standard textbook properly, the maker's manual for the engine type you sailed on, and the SOLAS and IACS rules listed above. Examiners prefer a candidate who knows one engine well over one who has memorised ten engines badly.

  • Pounder's Marine Diesel Engines and Gas Turbines (Doug Woodyard): the reference for engine types, construction and operation.
  • Introduction to Marine Engineering (D.A. Taylor): clear explanations and sketches for Class 4 and EOOW level.
  • Reed's Marine Engineering and Technology series, Vol. 12, Motor Engineering Knowledge for Marine Engineers: written-exam level detail, useful for Class 2.
  • Reed's Vol. 8, General Engineering Knowledge for Marine Engineers: auxiliary systems around the engine.
  • The engine maker's instruction and operating manuals for MAN or WinGD engines you have sailed with: emergency procedures, limits, overhaul steps.
  • SOLAS Chapter II-1 (Regs. 26 to 31 and Part E) and IACS Unified Requirements M3, M9, M10, M35.

For a fuller reading list see books for MEO Class 4. To plan the weeks before your exam, use the 30-day oral preparation plan and the oral exam day checklist. Check your readiness with the oral readiness check.

How can you practise main engine questions before the exam?

Practise by answering out loud to someone who interrupts you, because that is how the oral feels. Use our free tools first, then the voice examiner when it opens.

Run the mock oral drill with the questions on this page: read the question, answer without looking, then compare with the model answer. Test numbers with the main engine MCQ bank and the CES engine practice set, which also helps for CES tests for engineers and marine engineer interviews. Our AI voice mock examiner asks these questions aloud, follows up like an examiner and scores you; it is not live yet, and you can join early access.

Oral practice

38 oral questions with model answers

Read the question, answer it out loud as if the examiner is across the table, then open the model answer and mark yourself honestly.

–0/38 done
  1. 1
    Core

    Explain the working cycle of a two-stroke uniflow scavenged engine. Where do the events happen on the timing diagram?

    Model answer points
    • One power stroke every revolution; the piston uncovers scavenge ports near bottom dead centre.
    • Exhaust valve opens first (before the ports open) so cylinder pressure drops below scavenge pressure; this is the blowdown period.
    • Ports open, charge air sweeps upward through the cylinder and out through the exhaust valve (uniflow).
    • Ports close, then the exhaust valve closes; compression starts from valve closing.
    • Fuel is injected near top dead centre; combustion and expansion follow.
    • Uniflow gives better scavenging efficiency than loop or cross scavenge, which is why all modern slow-speed engines use it.
    The examiner may follow up with
    • Why does the exhaust valve open before the ports?
    • How does exhaust valve timing change compression pressure?
    How did you do?
  2. 2
    Core

    Why does a large slow-speed engine use a crosshead instead of a trunk piston?

    Model answer points
    • Side thrust from the connecting rod is taken by the crosshead guides, not the liner, so liner and ring wear are lower.
    • The piston rod moves in a straight line, so a stuffing box can seal it.
    • That separates the scavenge space from the crankcase, keeping combustion products and acidic residues out of the system oil.
    • Separate cylinder oil (high BN, matched to fuel sulphur) and system oil can then be used.
    • Allows very long stroke and low speed for a direct-coupled, efficient propeller.
    The examiner may follow up with
    • What happens if the stuffing box leaks?
    • How do you check stuffing box condition?
    How did you do?
  3. 3
    CoreEngine maker's instructions; company pre-departure checklist

    What checks do you make before starting the main engine after a port stay?

    Model answer points
    • Permits closed, all personnel clear, tools removed; turning gear disengaged and its interlock indicator showing.
    • Lube oil, cylinder oil, jacket water, fuel and cooling systems running, at temperature and pressure; jacket water preheated per maker.
    • Starting air receivers full, drains blown, main starting valve and distributor ready; control air on.
    • With the bridge's permission (propeller and surroundings clear), indicator cocks open and engine turned on air (blow-through) to show any water or oil in the cylinders; then indicator cocks closed.
    • Fuel at correct viscosity and temperature; auxiliary blowers on auto.
    • Bridge, engine room and local control positions tested; telegraph, clocks and communication checked; steering gear tested by the bridge.
    The examiner may follow up with
    • Why blow through with indicator cocks open?
    • What if water comes out of one indicator cock?
    How did you do?
  4. 4
    CoreIACS UR M35 (scavenge air box temperature alarm)

    What is a scavenge fire, what causes it and how do you recognise one?

    Model answer points
    • A fire of oil and carbon deposits in the scavenge air space.
    • Fuel comes from cylinder oil drained down the liner, unburnt fuel, carbon, and system oil leaking past the stuffing box.
    • Ignition comes from blow-by of hot combustion gas past worn, broken or stuck rings, or from a liner problem.
    • Causes: excessive cylinder oil feed, poor combustion (bad fuel valves, late injection), worn rings or liner, blocked scavenge drains, overload.
    • Signs: high scavenge temperature at one unit (scavenge fire alarm), high exhaust temperature, power loss, smoke or sparks from drains, hot doors.
    The examiner may follow up with
    • How would you reduce scavenge fire risk in daily practice?
    • What extinguishing systems are fitted to the scavenge space?
    How did you do?
  5. 5
    CoreEngine maker's instructions; IACS UR M10 (scavenge space relief valves and fire extinguishing)

    Walk me through your actions if a scavenge fire alarm sounds on your watch.

    Model answer points
    • Inform the bridge and call the chief engineer; ask the bridge to reduce speed (slow or dead slow as the maker requires).
    • Cut off fuel to the affected cylinder; increase cylinder lubrication to it.
    • Close scavenge drain cocks; keep everyone clear of scavenge doors and relief valves.
    • Watch adjacent units; small fires often burn out within minutes at reduced load.
    • If it spreads or does not die out: stop the engine (bridge agreement), stop auxiliary blowers, engage turning gear, use the fixed extinguishing system.
    • Do not open scavenge doors until it is out and cool; then inspect, clean, find the cause and log it.
    The examiner may follow up with
    • Why not open the doors to fight the fire?
    • When would you use the fixed system?
    How did you do?
  6. 6
    CoreIACS UR M10

    What is the purpose of the scavenge space relief valves and the fire extinguishing connections?

    Model answer points
    • Relief valves on scavenge spaces open to the cylinders limit pressure if deposits explode or a fire flashes; UR M10 requires them.
    • They are spring-loaded and should be tested and kept free of oil and paint.
    • The fixed extinguishing connections (CO2, steam or dry powder, depending on the maker and ship) let you smother a fire without opening doors.
    • The medium is only used with the engine stopped; injecting CO2 into a running engine would be drawn through the cylinders.
    • Check their condition at every scavenge inspection.
    The examiner may follow up with
    • How would you test a scavenge relief valve?
    How did you do?
  7. 7
    CoreIACS UR M9, M10

    How does a crankcase explosion happen, and why is the secondary explosion more dangerous?

    Model answer points
    • A hot spot (an overheated bearing or other part) vaporises lube oil splashing on it.
    • The vapour condenses into a fine white mist; when the mist is in the explosive range and meets the hot spot, it ignites.
    • The primary explosion builds pressure; relief valves open and then close.
    • If doors or relief valves fail, or someone opens a door, air rushes into the partial vacuum after the flame.
    • The fresh air mixes with remaining mist and the hot spot ignites it again: the secondary explosion.
    • It is more violent because the crankcase now has plenty of oxygen and turbulence, so the flame runs through the whole crankcase; it often blows doors off and starts an engine-room fire. That is why relief valves must reclose at once and doors must stay shut.
    • Hot spots: bearings, crosshead, piston rod rubbing in the stuffing box, chain drive, blow-by heating, fire in the scavenge space.
    The examiner may follow up with
    • What makes the secondary explosion worse?
    • Which hot spots does a main bearing temperature sensor miss?
    How did you do?
  8. 8
    CoreIACS UR M10; engine maker's instructions

    The oil mist detector alarms on the main engine at sea. What do you do?

    Model answer points
    • Engine slows down automatically (low-speed engine); inform the bridge and call the chief engineer.
    • Check whether it is real: look at all sensor readings and trends, bearing temperatures, splash oil temperature, smell and noise at a safe distance.
    • Ask the bridge for permission to stop; stop the engine when safe for navigation.
    • Keep people away from crankcase doors and relief valves; do not open doors until the engine has cooled (warning notice).
    • Follow the maker's procedure on lube oil circulation and turning gear, then open under a permit and look for the hot spot.
    • Find and repair the cause, test the OMD, record and report before restarting.
    The examiner may follow up with
    • How long would you wait before opening the crankcase?
    • How do you prove the OMD works after repair?
    How did you do?
  9. 9
    CoreSOLAS Ch. II-1 Reg. 27; IACS UR M9.1, M10

    Which engines need crankcase explosion relief valves and how many?

    Model answer points
    • SOLAS: engines with cylinder bore 200 mm and above, or crankcase volume 0.6 m³ and above.
    • IACS UR M9: bore up to 250 mm, one valve near each end, plus a middle one if more than eight throws.
    • Bore over 250 mm up to 300 mm: one valve at each alternate crank throw, minimum two.
    • Bore over 300 mm: one valve at each main crank throw.
    • Gear or chain cases over 0.6 m³ need their own relief valves (UR M10).
    The examiner may follow up with
    • What area must each valve have?
    How did you do?
  10. 10
    CoreIACS UR M9.2 to M9.11

    Describe a crankcase relief valve and how you maintain it.

    Model answer points
    • Lightweight spring-loaded disc (or other quick-acting device) seated on the door, with a flame arrester inside.
    • Opens quickly and is fully open at not more than 0.2 bar (0.02 N/mm²), then closes again at once to stop air inrush.
    • Each valve at least 45 cm² free area; total at least 115 cm² per m³ of crankcase gross volume.
    • Discharge is directed away from where people stand; a shield may be fitted.
    • Maintenance: check free movement, spring, seal and flame arrester cleanliness (oil or paint blocks it) as per the maker's manual kept on board.
    The examiner may follow up with
    • Why must it close again after opening?
    How did you do?
  11. 11
    CoreIACS UR M35; IACS UR M30

    What alarms and slowdowns protect the main engine in an unattended engine room?

    Model answer points
    • Lube oil: low inlet pressure, high temperature; bearing or oil mist alarms with slowdown.
    • Cooling: low jacket water pressure, high outlet temperature, oil in cooling water where relevant.
    • Scavenge: high scavenge box temperature (fire), high water level in the scavenge receiver.
    • Exhaust: high temperature after each cylinder and deviation from average, before and after turbocharger.
    • Starting and control air low pressure; wrong-way running; overspeed shutdown; control system power failure.
    • Least drastic action first: alarm, then slowdown, then shutdown.
    The examiner may follow up with
    • Which of these can the bridge override?
    How did you do?
  12. 12
    CoreSOLAS Ch. II-1 Reg. 27; IACS UR M9, M10

    How do you prevent a crankcase explosion in day-to-day running?

    Model answer points
    • Stop hot spots forming: correct bearing clearances, good lube oil pressure, temperature and cleanliness, and checks of crosshead, crankpin and main bearing temperatures.
    • Keep oil quality: purify system oil, analyse samples, watch for water and fuel dilution.
    • Keep the OMD (or bearing temperature monitoring) working and tested; act on the first alarm.
    • Maintain relief valves and flame arresters so they open and reclose; keep crankcase doors tight.
    • Watch stuffing box drains and piston cooling; blow-by and scavenge fires can heat the crankcase.
    • Never open crankcase doors soon after stopping a hot engine; follow the cooling time on the warning notice.
    The examiner may follow up with
    • What is a hot spot?
    • Why does a falling lube oil pressure matter here?
    How did you do?
  13. 13
    DeeperSOLAS Ch. II-1 Reg. 31; SOLAS Ch. II-1 Reg. 34

    Explain the starting air sequence on a reversible two-stroke engine.

    Model answer points
    • Bridge or local start order opens the main starting valve; air goes to the starting air manifold.
    • Starting air distributor (cam or timed control) sends pilot air to the starting valve of the cylinder in the right position for the selected direction.
    • Starting valves admit air to cylinders on the power stroke in turn until the engine reaches firing speed.
    • Fuel is then admitted and air is shut off; repeated failed attempts are limited so air remains for local starting.
    • Interlocks: turning gear engaged, wrong-way, telegraph mismatch, auxiliary blowers not running, low control air.
    • Non-return valves and flame arresters or bursting discs on the starting air pipes protect against starting air line explosions.
    The examiner may follow up with
    • What causes a starting air line explosion?
    • What happens if a starting valve sticks open?
    How did you do?
  14. 14
    DeeperSOLAS Ch. II-1 Reg. 31

    The engine fails to start from the bridge. Walk me through the fault-finding.

    Model answer points
    • Check the obvious: alarms on the control panel, turning gear indicator, starting air pressure, control and safety air pressure.
    • Is the main starting valve opening? Is the distributor getting air? Is a slow-turning or other interlock active?
    • If it turns on air but does not fire: fuel limiter, fuel pressure and temperature, fuel pumps or injection control, start-level setting.
    • If it does not turn: main start valve, starting valves, distributor timing, blocked or leaking starting air pipes.
    • Change to engine control room or local control and try again, informing the bridge.
    • Find the root cause before the next manoeuvre and record it.
    The examiner may follow up with
    • What is slow turning and why is it done?
    How did you do?
  15. 15
    Deeper

    What is the purpose of the auxiliary blowers and when do they run?

    Model answer points
    • At low load the turbocharger cannot supply enough scavenge air.
    • Auxiliary (electric) blowers supply air during starting and at low load.
    • They start automatically when scavenge pressure falls below a set value and stop when it rises.
    • Starting is often interlocked so the engine does not start without blowers running.
    • A blower fault at low load causes poor combustion, smoke, fouling and scavenge fire risk.
    The examiner may follow up with
    • What happens to a blower during a blackout?
    How did you do?
  16. 16
    Deeper

    What is turbocharger surging, what causes it and what do you do?

    Model answer points
    • Surging is a breakdown of airflow through the compressor: air flows back, causing a loud bark or roar and pressure fluctuation.
    • Causes: fouled air cooler or air filter, fouled nozzle ring or turbine, damaged blades, scavenge ports blocked, sudden load change, exhaust valve or fuel faults on one unit, heavy weather racing.
    • Action: reduce load, inform the bridge, check exhaust and scavenge temperatures per cylinder, check air cooler pressure drop.
    • Cleaning: compressor water wash and turbine dry or wet wash at intervals given by the maker.
    • Persistent surging needs inspection of the turbocharger and cylinders.
    The examiner may follow up with
    • How do you water wash the compressor side?
    How did you do?
  17. 17
    DeeperIACS UR M35

    Why does the engine slow down on high scavenge air temperature and high cooler water level?

    Model answer points
    • High scavenge temperature on one unit suggests a scavenge fire or blow-by; slowing down reduces heat and fuel.
    • High general scavenge temperature reduces air density, raising thermal load.
    • Water in the scavenge receiver (from a leaking or condensing air cooler) can be carried into cylinders, washing oil off the liner and causing cold corrosion and ring breakage.
    • Water mist catchers and drains should be checked every watch.
    The examiner may follow up with
    • What causes condensation in the air cooler?
    How did you do?
  18. 18
    Deeper

    How do you take crankshaft deflections and what do the readings show?

    Model answer points
    • Engine stopped and isolated, turning gear engaged, permit to work, crankcase ventilated and safe to enter.
    • Dial gauge placed in the punch marks between webs at the maker's position.
    • Readings at set crank angles (near BDC both sides, horizontal both sides, near TDC) and recorded with engine temperature and ship's draught.
    • Closing at TDC and opening at BDC (or the reverse) shows bearing misalignment: high or low bearings.
    • Compare with earlier readings, adjacent units and maker's limits; consider hull deflection with loading.
    • Out-of-limit readings: check bearing clearances, chocks, holding-down bolts, then report to the chief engineer and class if needed.
    The examiner may follow up with
    • Why does ship loading change deflections?
    • How does a worn main bearing show on the deflection readings?
    How did you do?
  19. 19
    DeeperEngine maker's overhaul instructions

    Walk me through a piston overhaul on a two-stroke engine.

    Model answer points
    • Plan: spares, tools, lifting gear, permit to work, bridge informed, engine isolated, turning gear engaged and locked, starting air shut and vented.
    • Drain cooling water as needed; remove cylinder cover with hydraulic tools; remove exhaust valve or cover assembly.
    • Clean the liner top and ridge; lift the piston with the maker's lifting tool after disconnecting the piston rod from the crosshead.
    • Inspect and measure: crown burning, ring grooves, ring clearances, piston rod, stuffing box.
    • Measure liner wear and inspect liner surface; renew rings and parts as per manual.
    • Reassemble with correct torques and hydraulic pressures, renew O-rings, pressure test cooling, turn on air, run in and record.
    The examiner may follow up with
    • How do you measure piston crown burning?
    • What run-in procedure follows new rings or a new liner?
    How did you do?
  20. 20
    Deeper

    How do you inspect the cylinders through the scavenge ports and what are you looking for?

    Model answer points
    • Engine stopped, isolated, turning gear engaged, scavenge space ventilated and safe, permit to work.
    • Turn each piston past the ports and look at rings, piston crown edge, skirt, liner surface and ports.
    • Look for: broken, stuck or collapsed rings, scuffing or scratches, clover-leafing, black dry or very wet liner surface, deposits, cracks.
    • Check ring movement with a soft tool, and condition of the stuffing box and drains.
    • Record per unit; compare trends; adjust cylinder oil feed or plan overhauls.
    The examiner may follow up with
    • What does a wet black liner tell you?
    • What is clover-leafing?
    How did you do?
  21. 21
    DeeperMARPOL Annex VI Reg. 14 (sulphur limits)

    How do you set the cylinder oil feed rate when the ship changes between fuels of different sulphur content?

    Model answer points
    • Cylinder oil base number (BN) neutralises sulphuric acid formed from fuel sulphur.
    • High BN oil with low-sulphur fuel leaves excess alkaline additives: deposits, bore polishing, ring sticking.
    • Low BN oil with high-sulphur fuel (scrubber ships) gives cold corrosion and high liner wear.
    • Feed rate follows the maker's guidance (often load and sulphur dependent) with a minimum feed rate.
    • Use scavenge drain oil analysis (residual BN and iron content) and port inspections to fine-tune.
    • Plan cylinder oil changeover with the fuel changeover, especially entering an ECA.
    The examiner may follow up with
    • What is cold corrosion?
    • How does a scrubber ship's cylinder oil plan differ?
    How did you do?
  22. 22
    Deeper

    What causes high liner wear on one unit?

    Model answer points
    • Under-lubrication or blocked quill, wrong cylinder oil BN for the fuel, cold corrosion from water or low liner temperature.
    • Abrasive wear: cat fines (aluminium and silicon) in poorly purified fuel, dirt in scavenge air.
    • Adhesive wear (scuffing) from overload, poor ring condition, breaking in too fast.
    • Poor combustion: faulty fuel valve, wrong timing, water in fuel.
    • Prove it with liner calipering, drain oil analysis, port inspection, fuel analysis and cylinder pressures.
    The examiner may follow up with
    • How would you check the fuel purifier performance against cat fines?
    How did you do?
  23. 23
    DeeperIACS UR M3.1

    What is the purpose of a governor and an overspeed trip, and what do the rules require?

    Model answer points
    • Governor keeps speed at the set value as load changes (heavy weather, propeller racing).
    • IACS UR M3: governor so that speed cannot exceed rated speed by more than 15%.
    • Separate overspeed protective device, independent of the governor, for engines of 220 kW and above that can be declutched or drive a CP propeller: speed limited to 120% of rated.
    • Overspeed on the main engine is a shutdown, not a slowdown.
    • Test the overspeed trip as per the planned maintenance system and record.
    The examiner may follow up with
    • How do you test an overspeed trip on a direct-drive engine?
    How did you do?
  24. 24
    Deeper

    What is a barred speed range and why does it exist?

    Model answer points
    • A range of engine speeds where torsional vibration of the shafting is too high (critical speed).
    • Marked on the bridge and engine room tachometers; the engine should pass through it quickly, not run in it.
    • Running in it can cause crankshaft or shaft failure, gear damage or loosening.
    • The range can change when a unit is cut out or a vibration damper fails.
    • Control systems may pass through it automatically; the bridge must know.
    The examiner may follow up with
    • What happens to the barred range if a cylinder is cut out?
    How did you do?
  25. 25
    Deeper

    Explain the purpose and checks of the main engine lube oil system.

    Model answer points
    • System oil lubricates and cools bearings, crossheads, camshaft or hydraulic systems, and in many engines cools pistons.
    • Circulates from the sump tank via pumps, coolers, fine filters and back; a purifier runs continuously on the sump tank.
    • Checks: pressure at inlet and to crossheads, temperature in and out, filter differential pressure, sump level, purifier running.
    • Regular sample analysis: viscosity, water, BN, insolubles, metals.
    • Rising sump level may mean water ingress (cooler leak, jacket water) or fuel contamination; falling level means leakage or high consumption.
    The examiner may follow up with
    • What would you do if water is found in the system oil?
    How did you do?
  26. 26
    Deeper

    Jacket water temperature is rising on all units. What could be the cause and what do you do?

    Model answer points
    • Check: central cooler sea water side fouled, sea water pump problem, sea chest blocked, thermostatic valve fault, low expansion tank level.
    • Air in the system or a gas leak into the jacket water (cracked cover or liner) will show as falling level or bubbles in the expansion tank.
    • Reduce load if needed and inform the bridge; start standby pumps.
    • Check cooling water treatment and the fresh water generator, which uses jacket water heat (see the FWG topic).
    • Record and find the root cause before full load.
    The examiner may follow up with
    • How would you detect a cracked cylinder cover?
    How did you do?
  27. 27
    Deeper

    What is the role of the thrust block and how is it monitored?

    Model answer points
    • Transfers propeller thrust from the shaft to the hull through the engine bedplate or a separate seating.
    • Thrust collar runs between pads (Michell type) on an oil film.
    • Monitored by thrust pad temperature alarms and periodic axial clearance checks.
    • High temperature: lubrication failure, overload, misalignment, wiped pads.
    • Fault means reducing speed and possibly stopping, as loss of the thrust bearing can damage the engine.
    The examiner may follow up with
    • How do you measure thrust clearance?
    How did you do?
  28. 28
    DeeperISM Code (safe working procedures)

    What are the hazards when working inside the crankcase and how do you control them?

    Model answer points
    • Engine rotating unexpectedly: turning gear engaged and locked, starting air shut and vented, control system blocked, warning signs.
    • Hot surfaces and residual oil mist; allow cooling and ventilate.
    • Enclosed space risks if large and poorly ventilated; follow the ship's entry procedure.
    • Slippery surfaces, falling objects, trapping between webs.
    • Permit to work, toolbox talk, a standby person and a count of tools in and out.
    The examiner may follow up with
    • What is your procedure if a tool is left inside?
    How did you do?
  29. 29
    Deeper

    What is the stuffing box drain telling you and when do you overhaul it?

    Model answer points
    • Upper part drains scavenge oil and dirt; lower part drains system oil scraped from the rod.
    • Rising flow or dirty drain oil means worn rings or springs, or a scored piston rod.
    • System oil contamination (high insolubles, BN rising) can come from a leaking stuffing box.
    • Overhaul at piston overhauls or when drain checks show leakage: rings, springs, clearances per maker.
    • Piston rod surface is checked for scoring and polished or repaired as needed.
    The examiner may follow up with
    • How does a leaking stuffing box affect system oil BN?
    How did you do?
  30. 30
    DeeperIACS UR M10; IACS UR M67; maker's instructions

    How do you test an oil mist detector, and how do you know it is healthy?

    Model answer points
    • Know the type first: older sampling types draw air from each unit through pipes to a measuring and reference cell; modern point-type detectors have a sensor at each crankcase compartment measuring light scatter.
    • Daily: no fault alarm, readings steady and similar between units, sampling fan or suction working, sensor heaters normal.
    • Function test as per the maker and the PMS: apply test smoke or the maker's test device at each sensor (or use the built-in self-test) and confirm the alarm sounds and the slowdown signal reaches the safety system.
    • Clean lenses and sampling pipes and check pipe drains so oil or water does not block them; a blocked pipe hides a hot spot.
    • After any repair or sensor change, test that unit's channel before relying on it.
    • Record the test; OMDs must be type-approved (IACS UR M67) and fitted where UR M10 requires them.
    The examiner may follow up with
    • What is the difference between an alarm and a slowdown from the OMD?
    • What other system can be accepted instead of an OMD?
    How did you do?
  31. 31
    Trap

    The main engine must run with one cylinder cut out. What do you do?

    Model answer points
    • This is a decision for the chief engineer with company input, not just the watchkeeper.
    • Follow the maker's instructions for cutting out (fuel only, or fuel and exhaust valve, or piston removed and covers blanked).
    • Reduce load to the maker's limit; watch exhaust temperatures, turbocharger behaviour and surging.
    • The barred speed range can change: check the maker's torsional vibration guidance and inform the bridge.
    • Inform company and class; record in the log; plan repair at the next port.
    • Trap: candidates keep full speed. The answer is reduced, controlled load with documented limits.
    The examiner may follow up with
    • Who must you inform outside the ship?
    How did you do?
  32. 32
    TrapIACS UR M10 (warning notice on crankcase doors)

    After an oil mist alarm, the second engineer wants to open a crankcase door straight away to look. What do you say?

    Model answer points
    • No: the warning notice required by UR M10 says not to open doors or sight holes until the engine has cooled enough.
    • Opening admits air into a crankcase that may still have mist and a hot spot: secondary explosion risk.
    • Stop the engine, keep people away from the doors and relief valves, wait the maker's cooling period.
    • Ventilate before entry and follow the permit and enclosed space rules.
    • Escalate to the chief engineer if there is disagreement; safety overrides rank.
    The examiner may follow up with
    • What would you do if you saw smoke from the relief valves?
    How did you do?
  33. 33
    TrapIACS UR M9, M10

    If the crankcase relief valves are there, why do you still need an oil mist detector?

    Model answer points
    • Relief valves only limit the damage once an explosion has started; they do not prevent it.
    • The OMD gives early warning while the mist is building, so you can slow down and stop before ignition.
    • Both are required, each for a different job: UR M9 for relief, UR M10 for detection.
    • Bearing temperature monitoring may be accepted as an equivalent for detection, not for relief.
    The examiner may follow up with
    • What equivalent to an OMD may be accepted?
    How did you do?
  34. 34
    TrapEngine maker's instructions

    Is it a good idea to inject CO2 into the scavenge space while the engine is still running?

    Model answer points
    • No. With the engine running the medium is drawn through the cylinders and lost, and the fire continues.
    • The fixed system is used with the engine stopped and the auxiliary blowers off.
    • First actions are reducing load, cutting fuel to the unit and increasing cylinder oil; many scavenge fires die out at reduced load.
    • Follow the maker's instruction, which states the medium and the procedure for your engine.
    The examiner may follow up with
    • What is the risk of opening scavenge doors too early?
    How did you do?
  35. 35
    TrapISM Code section 5 (master's overriding authority); IACS UR M35 (slowdown override)

    The bridge asks for full ahead immediately after you report a scavenge fire. What do you do?

    Model answer points
    • Explain the risk to the master: high load feeds the fire and can spread it to other units or cause an explosion.
    • If the ship is in danger (collision, grounding), the master decides; the bridge has the override for slowdowns.
    • Give the safest power you can, cut fuel to the affected unit and monitor closely.
    • Record the order and the times; inform the chief engineer at once.
    • Trap: candidates either refuse outright or comply silently. The right answer is advise, then follow the master's decision for ship safety.
    The examiner may follow up with
    • Which shutdowns can never be overridden?
    How did you do?
  36. 36
    TrapSOLAS Ch. II-1 Reg. 34 (protection against internal explosion)

    A starting air pipe to one cylinder is very hot after manoeuvring. What does it mean and what is the danger?

    Model answer points
    • The cylinder starting valve is leaking or stuck open, letting hot combustion gas back into the starting air line.
    • Oil in the starting air line (from compressor carry-over) can ignite: starting air line explosion.
    • Action: inform the bridge, stop the engine when safe, shut the starting air, find and overhaul the leaking valve.
    • Flame arresters or bursting discs and non-return valves on the line limit the damage; check them after the incident.
    • Prevention: drain receivers and lines, keep compressor oil carry-over low, maintain starting valves.
    The examiner may follow up with
    • Where are bursting discs fitted on the starting air system?
    How did you do?
  37. 37
    Trap

    You find white metal flakes in the main engine lube oil filter. Do you keep running?

    Model answer points
    • White metal means a bearing is wiping; this is a hot spot risk and an oil mist risk.
    • Inform the chief engineer and bridge; reduce load and prepare to stop when safe.
    • Check OMD readings, bearing temperatures and the filter for quantity and type of metal.
    • Stop, isolate, allow cooling, then inspect bearings in order (crosshead, crankpin, main) to find the source.
    • Do not just clean the filter and carry on; record and report.
    The examiner may follow up with
    • How would you identify which bearing it came from?
    How did you do?
  38. 38
    TrapMARPOL Annex VI Reg. 14

    Fuel in use is changed before entering an ECA and the engine starts to lose power with high exhaust temperatures. What could be wrong?

    Model answer points
    • Low-viscosity distillate may cause fuel pump and injector leakage and low injection pressure; check viscosity at engine inlet and cooler operation.
    • Incompatibility between residual and low-sulphur fuels can form sludge, blocking filters and purifiers.
    • Thermal shock if temperature changed too fast during changeover, causing pump sticking.
    • Cylinder oil BN may now be wrong for the new fuel.
    • Follow the ship's fuel changeover procedure and keep the records the sulphur rules require.
    The examiner may follow up with
    • What records do you keep for the changeover?
    How did you do?

Reading answers is not the same as saying them. Our AI voice examiner asks these out loud, listens to your answer, asks the follow-up and marks you against the rule. Join early access or try the free timed mock oral drill.

Frequently asked questions

What is the most asked main engine question in the MEO Class 4 oral?

Scavenge fire and crankcase explosion come up in almost every engine oral, with the starting air system close behind. Expect to explain causes, first actions and the safety devices involved. Practise the sequence until you can say it without pausing.

Why do two-stroke engines get scavenge fires and four-stroke engines do not?

In a crosshead two-stroke engine the scavenge space collects cylinder oil and carbon that drain down from the liner, and hot gas can blow past the rings into it. A four-stroke trunk piston engine has no separate scavenge space; its risk is in the crankcase instead.

At what pressure do crankcase relief valves open?

IACS UR M9 requires the valves to be quick-acting and fully open at a pressure not greater than 0.2 bar. Each valve needs at least 45 cm² of free area and the total must be at least 115 cm² per cubic metre of crankcase volume.

Which engines must have an oil mist detector?

Under IACS UR M10 and the SOLAS rules for unattended machinery spaces, diesel engines of 2,250 kW and above or with bores over 300 mm need oil mist detection or an accepted equivalent such as bearing temperature monitoring. On low-speed engines it gives alarm and slowdown.

Should you stop the main engine on an oil mist alarm?

The engine slows down automatically on a low-speed engine. You inform the bridge and the chief engineer, check that the alarm is genuine and stop the engine when the bridge says it is safe to do so. You do not open the crankcase until the engine has cooled.

What is the difference between slowdown and shutdown?

A slowdown reduces engine load to protect it while keeping propulsion, for example on high scavenge temperature or oil mist on a main engine. A shutdown stops the engine, for example on overspeed or loss of lube oil pressure. The bridge can override some slowdowns and shutdowns in an emergency.

What causes high exhaust temperature on one cylinder?

Common causes are a leaking or sticking fuel valve, a burnt or leaking exhaust valve, blow-by past the rings, a scavenge fire starting, a fuel pump fault or late injection. Compare scavenge temperature and the cylinder pressure readings to narrow it down.

How are crankshaft deflections taken?

A dial gauge is fitted between the crank webs at the maker's marked position and read at set crank angles as the engine is turned. Readings are compared with earlier ones and with the maker's limits, taking hull loading and engine temperature into account.

What is the stuffing box for on a crosshead engine?

It seals the piston rod where it passes from the scavenge space into the crankcase. The upper rings keep scavenge air and dirt out, and the lower scraper rings keep system oil in. Its drain oil is checked for leakage and contamination.

Is the main engine examined in the MCA EOOW oral?

Yes. The MCA EOOW oral uses routine, non-routine and contingency scenarios for engineers on ships of 750 kW or more, so main engine alarms, starting failures and emergencies are typical. The syllabus is in MIN 654.

How long should I study the main engine for the oral?

Most candidates need several weeks on engines alone, alongside other topics. Spread it over your preparation plan and practise aloud every few days rather than reading in one block.

Do examiners ask about electronic engines?

Yes, especially at Class 2 and Class 1. Expect questions on common rail or hydraulically actuated fuel injection and exhaust valves, the control system and what you do if the engine control system fails. Know your ship's backup and local control arrangements.

Sources 9 documents

Each number in the text links to the source below. Labels show the type of source; see our editorial policy.

  1. Official MSN 1857 (M+F) Amendment 1: UK requirements for engineer officers and engineer operators
  2. Official Isle of Man SD 603/98 Merchant Shipping (Cargo Ship Construction) Regulations 1998 (transposing SOLAS Ch. II-1 Reg. 27.4) · 1 January 1998
  3. Reported Turk Loydu TL-R M (January 2023), reproducing IACS UR M9 Crankcase explosion relief valves · 1 January 2023
  4. Reported Turk Loydu TL-R M (January 2023), reproducing IACS UR M10 Protection of internal combustion engines against crankcase explosions · 1 January 2023
  5. Reported Turk Loydu TL-R M (January 2023), reproducing IACS UR M3 Speed governor and overspeed protective device · 1 January 2023
  6. Official STCW Code Section A-I/1 (as amended 2010) · 25 June 2010
  7. Official MIN 654 (M) Engineering and Electro-technical Officer Oral Exam Syllabus, Amendment 1 (April 2026) · 21 April 2026
  8. Reported Turk Loydu TL-R M (January 2023), reproducing IACS UR M35 · 1 January 2023
  9. Official Isle of Man SD 603/98 Merchant Shipping (Cargo Ship Construction) Regulations 1998, machinery controls (transposing SOLAS Ch. II-1 Reg. 31) · 1 January 1998

Where should you go next?

  • Oral topics14 pages: examiner questions with model answer points, deck and engine
  • Question banks7 pages: free MCQ sets with answers and explanations
  • CoC exam guides16 pages: every oral and written exam, authority by authority
  • Free tools4 pages: mock oral drill, lights trainer, sea-time calculator, practice tests
Exam Prep DeskMaritime exam researchers

We write from the conventions (STCW, COLREG, SOLAS, MARPOL), the authorities' own notices and published syllabi, and cite the source for every fee, rule and date. We are independent and not linked to any maritime administration or test provider. Found an error? It matters at sea: tell us and see how we correct · Disclaimer.

Related guides

AI voice mock oral

Say it out loud before the examiner asks.

Our examiner asks CoC oral questions by rank and function, listens to your answer, asks the follow-up and scores you against the rule. Early access is open for India first.

  • Deck and engine, every rank
  • Answers referenced to the conventions
  • Independent, not linked to any authority
WhatsApp us