NautemyCoC orals · exams · job testsEarly access
Question bank22 min readJump to 40 questions

MARPOL MCQ practice: 40 questions on Annexes I to VI with answers and explanations

These 40 free MARPOL MCQ questions cover all six annexes: oily bilge discharge at 15 ppm, oil record books, NLS categories, sewage and garbage distances, the 0.50% sulphur cap, ECAs, EEXI and CII. Every answer has a short explanation and the exact regulation.

On this page
  1. Key facts
  2. How should you use these MARPOL MCQs?
  3. What are the 10 MARPOL rules and numbers you must know?
  4. What are the common traps in MARPOL questions?
  5. How do you work the calculation questions on MARPOL?
  6. Which traps does this MARPOL set use, and what is the rule?
  7. MARPOL revision table
  8. Where is MARPOL examined?
  9. What should you study after this MARPOL set?
  10. 40 practice questions
  11. Frequently asked questions
  12. Sources

Key facts

Questions
38 multiple choice, 4 options each
Covers
MARPOL Annexes I, II, III, IV, V and VI, plus a little ballast water
Levels
Core, deeper and trap questions
Who it suits
2nd mate, chief mate, MEO Class 4 and 2, OOW and EOOW candidates
Global sulphur limit
0.50% m/m since 1 January 2020[1]
Newest SOx ECA
Mediterranean, from 1 May 2025[2]
Cost
Free, no sign-up

Checked 14 November 2026. Fees and rules change: confirm with the authority before you book.

How should you use these MARPOL MCQs?

Answer each question before you open the explanation, then check the regulation named in the reference. Mark every miss and come back to it after two days. That simple loop of test, check and retest is how the numbers stay in your head on exam day.

The set moves from core recall (what is the 15 ppm rule) to deeper application (which records, which certificates, which ships) and then to traps, where two options look right and only one matches the text of MARPOL. Trap questions are where most candidates lose marks in written papers and get pulled apart in orals.

Use the set three ways:

  • Timed run. Do all 40 in 30 minutes in the practice test tool. Aim for 34 or more before you book your exam.
  • Speak the answer. For each question, say the full answer aloud as if an examiner asked it, with the regulation number. Then drill the same ground in the mock oral drill, because an oral examiner never gives you four options.
  • Link to the topic page. When a question shows a gap, read the matching part of our MARPOL oral topic page, which has examiner-style questions and model answers.

If you want an examiner that asks MARPOL questions out loud and follows up on weak answers, join the early access list for our AI voice mock examiner.

What are the 10 MARPOL rules and numbers you must know?

These ten numbers answer about half of all MARPOL questions in written papers and orals. Learn each with its regulation number, because examiners ask "where does it say that".

MARPOL in 10 rules and numbers
Rule or numberWhat it meansReference
15 ppmMaximum oil content of processed machinery-space bilge water discharged at sea, ship en route, through oil filtering equipmentMARPOL Annex I Reg. 15
30 litres per nautical mileMaximum instantaneous rate of discharge of oil from the cargo area of an oil tanker, more than 50 nm from land, outside special areasMARPOL Annex I Reg. 34
150 GT / 400 GTOil tankers of 150 GT and above and other ships of 400 GT and above need an IOPP Certificate, an Oil Record Book and a SOPEPMARPOL Annex I Regs. 6, 17, 37
3 yearsOil Record Book kept on board for three years after the last entryMARPOL Annex I Reg. 17
12 nm, 25 m, 7 knotsMinimum distance from land, depth of water and speed for discharge of permitted NLS residues (Categories X, Y, Z)MARPOL Annex II Reg. 13
3 nm / 12 nmSewage: comminuted and disinfected beyond 3 nm; untreated beyond 12 nm at not less than 4 knotsMARPOL Annex IV Reg. 11
Plastics: neverDischarge of all plastics into the sea is prohibited everywhereMARPOL Annex V Reg. 3
Food waste 3 nm / 12 nmOutside special areas: comminuted food waste beyond 3 nm, uncomminuted beyond 12 nm, ship en routeMARPOL Annex V Reg. 4
0.50% / 0.10% sulphurFuel sulphur limit outside and inside SOx Emission Control AreasMARPOL Annex VI Reg. 14
CII A to EAnnual operational carbon intensity rating; D for three years running or one E triggers a corrective action plan in the SEEMPMARPOL Annex VI Regs. 28 and 26

What are the common traps in MARPOL questions?

The most common MARPOL trap is mixing up machinery-space bilge rules (Annex I Reg. 15, 15 ppm) with cargo-area rules for oil tankers (Annex I Reg. 34, 30 litres per nautical mile and 50 nm). Here are the others that cost marks:

  • "Special area" means a ban for everything. Not true. In Annex I special areas a ship may still discharge processed machinery-space bilge water at 15 ppm or less, en route, through equipment with an alarm and automatic stop. The Antarctic area is the strict exception. Tanker cargo-area discharges are prohibited in special areas.
  • Comminuted food waste is plastic-free food waste, not any waste. Food waste mixed with plastic is treated as plastic: no discharge.
  • Retention periods differ. The Oil Record Book is kept three years after the last entry; the Garbage Record Book two years; the bunker delivery note three years.
  • The sulphur limit is not just about use. Since 1 March 2020 a ship without a scrubber may not even carry non-compliant fuel for use on board[3].
  • Tier III NOx applies in NOx ECAs only, and only by build date. Tier III is not a global limit. Read the dates in Annex VI Reg. 13 before you answer.
  • Category X is the most harmful NLS category, not the least. Some candidates reverse X and Z. Remember X needs a prewash and the residues go to a reception facility.
  • Cooking oil is not food waste. It may not be discharged into the sea under Annex V.

If you keep falling for the same trap, the MARPOL oral topic page explains the reason behind each rule, which makes the numbers easier to remember. For the machinery side, see the oily water separator and fuel sulphur rules and scrubbers topic pages.

How do you work the calculation questions on MARPOL?

MARPOL looks like a list of numbers, but written papers turn several of those numbers into short calculations. Four types cover most of them.

Example 1: tanker discharge totals (questions 6 and 39). A tanker delivered after 31 December 1979 may discharge at most 1/30,000 of the previous cargo, and no more than 30 litres per nautical mile, more than 50 nm from land and en route. For a 90,000 t cargo: 90,000 ÷ 30,000 = 3 t in total. At 12 knots and the full 30 L/nm, the instantaneous limit allows 30 × 12 = 360 litres per hour. Taking the oil density as 0.9 t/m³, 3 t is about 3.3 m³, or 3,333 litres, which at 360 L/h would take over 9 hours of discharge at the maximum rate. In practice the oil discharge monitoring equipment stops the discharge long before that, and any residue that cannot meet the limits stays on board for reception facilities.

Example 2: distance and time for sewage and garbage (questions 16, 17, 19). Untreated sewage needs the ship en route, more than 12 nm from the nearest land and at not less than 4 knots[4]. A ship leaving port at 14 knots on a course straight away from the coast reaches 12 nm in 12 ÷ 14 = 0.86 hours, about 51 minutes. If the coast curves and the nearest land is a headland, measure from that, not from the departure port. Comminuted food waste outside special areas needs 3 nm; uncomminuted food waste needs 12 nm[5].

Example 3: ppm into litres (questions 1 and 8). A machinery-space bilge discharge of 6 m³ at 12 ppm releases 6,000 × 12 ÷ 1,000,000 = 0.072 litres of oil. The number is tiny, which is why a visible sheen means the equipment is not working and the discharge must stop (question 38).

Example 4: sulphur inside and outside ECAs (questions 25–28). A ship burns 30 t/day. Outside ECAs at 0.50% sulphur it emits about 30 × 0.005 = 0.15 t of sulphur a day, which becomes about 0.30 t of SO2 (sulphur's mass doubles as SO2, since 32 + 32 = 64). Inside an ECA at 0.10%, the same consumption gives 0.03 t of sulphur and about 0.06 t of SO2: one fifth. That ratio is what the ECA boundary is designed to achieve.

Examiner's note: A senior examiner may ask "how much oil could your tanker legally discharge on this ballast voyage?" The weak answer recites "30 litres per mile". The strong answer gives both limits (rate and total), works the 1/30,000 figure for the last cargo, and adds the 50 nm, en route and ODME conditions and the ban in special areas.

Which traps does this MARPOL set use, and what is the rule?

MARPOL distractors usually take a real number from the wrong annex, the wrong area or the wrong ship type. These are the patterns in this set.

Trap pattern Questions Rule that defeats it
Machinery bilge vs tanker cargo area 1, 5, 6, 39 15 ppm for machinery bilges (no distance rule). Cargo area: more than 50 nm, en route, 30 L/nm, 1/30,000 total. Pump-room bilges belong to the cargo rules.
Size thresholds 3, 10, 11, 18, 40 IOPP and SOPEP: tankers 150 GT, others 400 GT. ORB Part II: tankers 150 GT. Annex IV: 400 GT or more than 15 persons. Garbage Record Book: 100 GT since May 2024.
Special area lists 7, 9, 27 Gulf of Aden is an Annex I special area; Antarctic bans all oil discharge; the Mediterranean is a SOx ECA from 1 May 2025[6].
Record retention 4, 23, 29 ORB 3 years; Garbage Record Book 2 years; BDN 3 years.
Annex II categories 12, 13, 14 X is major hazard; Category Y washings go out en route at 7 knots or more, 12 nm or more from land, in water at least 25 m deep, below the waterline; operations go in the Cargo Record Book.
Sewage numbers 16, 17 3 nm comminuted and disinfected; 12 nm untreated at 4 knots or more.
Food waste numbers 2, 19, 20, 22 Outside special areas 3 nm (comminuted, 25 mm) or 12 nm; in special areas 12 nm and comminuted only; mixed with plastic means treat as plastic.
Cooking oil and plastics 21, 22 Cooking oil is garbage that may not be discharged at all.
Sulphur and carriage 25, 26, 28 0.50% outside, 0.10% in ECAs; non-compliant fuel may not even be carried for use without a scrubber.
NOx scope 30, 31 Over 130 kW; Tier III only inside NOx ECAs for ships built after each ECA's date.
Ozone and incinerators 32, 33 New HCFC installations banned; PCBs never incinerated.
Distance from what? 2, 16, 19, 36 MARPOL distances are from the nearest land (baseline); BWM exchange prefers 200 nm and 200 m depth.

Before choosing, name the annex and the ship type. If an option's number belongs to another annex, cross it out.

MARPOL revision table

Read across each row and test yourself on the middle column.

Quick revision for MARPOL
AnnexKey numbersReference
I (machinery)15 ppm en route; ORB kept 3 years; IOPP from 400 GTReg. 6, 15, 17
I (tanker cargo)More than 50 nm, en route, 30 L/nm, 1/30,000 totalReg. 34
I (special areas)Antarctic: no oil discharge; others 15 ppm with alarm and stopReg. 15
IICategory X/Y/Z; Y washings at 7 kn, 12 nm, 25 m depthReg. 6, 13
IIIGiven effect through the IMDG CodeReg. 1
IV400 GT or more than 15 persons; 3 nm / 12 nm at 4 knReg. 2, 11
VFood waste 3 nm (25 mm) / 12 nm; GRB from 100 GT; kept 2 yearsReg. 4, 6, 10
VI (SOx)0.50% global, 0.10% ECA; carriage banReg. 14
VI (NOx and ODS)Over 130 kW; Tier III in NOx ECAs; no new HCFCReg. 12, 13
VI (carbon)CII rated A–E; D for 3 years or E needs a corrective planReg. 28

Where is MARPOL examined?

MARPOL is examined at every officer level, deck and engine, in written papers and in orals. At operational level you are expected to know the discharge rules, the records and your own duties. At management level the examiner asks about certificates, surveys, port State control and how you would run compliance on board.

Company screening tests also test MARPOL. See CES for deck officers and CES for engineers.

What should you study after this MARPOL set?

Once you score well here, move to the topics MARPOL questions lean on:

  • Ballast water management: the D-1 and D-2 standards. All ships in scope had to meet D-2 by 8 September 2024[7].
  • Tanker operations for ODME, slop tanks and Oil Record Book Part II.
  • SOLAS MCQ and ISM and ISPS MCQ, because examiners link pollution prevention to the safety management system.
  • Cargo work MCQ for dangerous goods (Annex III and the IMDG Code).
  • Pumps and purifiers MCQ for engineers, where sludge and bilge handling meet MARPOL.

Before the oral, run through the oral exam day checklist.

Practice set

40 practice questions with answers

Pick an answer to see if it is right and why. Your score stays on this page only.

–0/40 done
  1. 1
    CoreMARPOL Annex I Reg. 15

    A cargo ship of 20,000 GT is en route outside any special area. What is the maximum oil content of machinery-space bilge water it may discharge through its oil filtering equipment?

    Show answer

    Answer: C. Annex I Reg. 15 allows discharge of processed machinery-space bilge water only when the oil content without dilution does not exceed 15 ppm. 30 litres per nautical mile is the tanker cargo-area rate under Reg. 34, not the bilge limit.

  2. 2
    DeeperMARPOL Annex V Reg. 6

    Inside an Annex V special area, under what conditions may a ship en route discharge food waste?

    Show answer

    Answer: A. Annex V Reg. 6 allows food waste in special areas only when comminuted or ground to pass a 25 mm screen, not mixed with other garbage, with the ship en route at least 12 nm from the nearest land or ice shelf. The 3 nm figure applies to comminuted food waste outside special areas.

  3. 3
    CoreMARPOL Annex I Reg. 6

    Which ships must carry an International Oil Pollution Prevention (IOPP) Certificate?

    Show answer

    Answer: D. Annex I Reg. 6 requires the IOPP Certificate for oil tankers of 150 GT and above and other ships of 400 GT and above (on voyages to ports or terminals of other Parties). The reversed thresholds are the classic trap.

  4. 4
    CoreMARPOL Annex I Reg. 17.6

    For how long must the Oil Record Book be retained on board after the last entry?

    Show answer

    Answer: B. Annex I Reg. 17 requires the Oil Record Book to be kept on board for three years after the last entry. Two years is the Garbage Record Book period under Annex V.

  5. 5
    DeeperMARPOL Annex I Reg. 15

    Bilge water from which space may NOT be processed and discharged under the 15 ppm rule of Annex I Reg. 15?

    Show answer

    Answer: B. Reg. 15 discharges must not originate from cargo pump-room bilges on oil tankers, and must not be mixed with oil cargo residues. Cargo pump-room bilges are cargo-area waste handled under the tanker rules.

  6. 6
    DeeperMARPOL Annex I Reg. 34

    An oil tanker wants to discharge oily mixtures from its cargo area outside a special area. Which condition is required?

    Show answer

    Answer: D. Annex I Reg. 34 sets cumulative conditions for tanker cargo-area discharges: more than 50 nm from the nearest land, en route, instantaneous rate not over 30 litres per nautical mile, ODME and slop tanks in operation, plus a total quantity limit. The 12 nm and 15 ppm figures belong to other rules.

  7. 7
    DeeperMARPOL Annex I Reg. 1

    Which of these is designated as a special area under MARPOL Annex I?

    Show answer

    Answer: A. The Gulf of Aden is an Annex I special area, as are the Mediterranean, Baltic, Black Sea, Red Sea, Gulfs area, Antarctic, North West European waters, Oman area of the Arabian Sea and Southern South African waters. The Bay of Bengal and South China Sea are not.

  8. 8
    TrapMARPOL Annex I Reg. 15.3

    A ship of 400 GT and above is en route inside the Mediterranean special area. Under what condition may it discharge machinery-space bilge water?

    Show answer

    Answer: C. Annex I Reg. 15 still permits processed bilge water at 15 ppm or less in special areas (except the Antarctic area) when the equipment has an alarm and automatic stopping device. Thinking 'special area means total ban' is the trap.

  9. 9
    TrapMARPOL Annex I Reg. 15.4

    In which MARPOL Annex I special area is the discharge of any oil or oily mixture from any ship prohibited?

    Show answer

    Answer: D. Annex I Reg. 15 prohibits any discharge of oil or oily mixture from any ship in the Antarctic area. In the other special areas processed bilge water at 15 ppm or less may still be discharged under conditions.

  10. 10
    CoreMARPOL Annex I Reg. 37

    Which ships must carry an approved Shipboard Oil Pollution Emergency Plan (SOPEP)?

    Show answer

    Answer: C. Annex I Reg. 37 uses the same thresholds as the IOPP Certificate. Some candidates think SOPEP is a tanker-only document; it is not.

  11. 11
    DeeperMARPOL Annex I Reg. 36

    The Oil Record Book Part II is required on which ships?

    Show answer

    Answer: B. Part II records cargo and ballast operations and is required on oil tankers of 150 GT and above. Part I (machinery space operations) is required on all ships within Annex I thresholds, including tankers.

  12. 12
    CoreMARPOL Annex II Reg. 6

    Under Annex II, which category of noxious liquid substance is considered a major hazard, so its discharge into the sea is prohibited?

    Show answer

    Answer: A. Category X substances present a major hazard and their residues go to a reception facility after a prewash. Category Z is the minor-hazard group, which candidates sometimes reverse with X.

  13. 13
    DeeperMARPOL Annex II Reg. 13

    A chemical tanker wants to discharge permitted Category Y tank washings. Which set of conditions applies?

    Show answer

    Answer: A. Annex II Reg. 13 sets 7 knots, 12 nm, 25 m depth and discharge below the waterline. The 200 nm and 200 m figures come from ballast water exchange, and 4 knots from sewage.

  14. 14
    CoreMARPOL Annex II Reg. 15

    Which document records cargo and ballast operations involving noxious liquid substances on a chemical tanker?

    Show answer

    Answer: B. Annex II requires a Cargo Record Book for NLS operations. The P&A Manual tells you how to do the operations; it does not record them.

  15. 15
    CoreMARPOL Annex III Reg. 1

    Annex III (harmful substances in packaged form) is given effect in practice mainly through which code?

    Show answer

    Answer: C. Packaged dangerous goods, including marine pollutants, are carried under the IMDG Code. The IBC Code covers chemicals in bulk (Annex II), the IGC Code liquefied gases in bulk and the IMSBC Code solid bulk cargoes.

  16. 16
    CoreMARPOL Annex IV Reg. 11

    Without an approved sewage treatment plant, a ship en route discharges comminuted and disinfected sewage. What is the minimum distance from the nearest land?

    Show answer

    Answer: D. Annex IV Reg. 11 allows comminuted and disinfected sewage beyond 3 nm. Sewage that is not comminuted or disinfected needs more than 12 nm, which is the tempting wrong choice.

  17. 17
    DeeperMARPOL Annex IV Reg. 11

    Untreated sewage from a holding tank is discharged more than 12 nm from land. What is the minimum speed of the ship required by Annex IV?

    Show answer

    Answer: C. Annex IV Reg. 11 requires a moderate rate of discharge while the ship is en route at not less than 4 knots. The 7 knots figure is from Annex II.

  18. 18
    DeeperMARPOL Annex IV Reg. 2

    Annex IV applies to ships on international voyages of which size?

    Show answer

    Answer: A. Annex IV Reg. 2 applies to new and existing ships of 400 GT and above, and to smaller ships certified to carry more than 15 persons. 150 GT is the oil-tanker threshold under Annex I.

  19. 19
    CoreMARPOL Annex V Reg. 4

    Outside special areas, a ship en route wants to discharge food waste that has NOT been comminuted. What is the minimum distance from the nearest land?

    Show answer

    Answer: D. Annex V Reg. 4 permits uncomminuted food waste beyond 12 nm. Comminuted food waste (able to pass a 25 mm screen) may go beyond 3 nm.

  20. 20
    DeeperMARPOL Annex V Reg. 4

    Food waste may be discharged at 3 nm from land outside special areas if it has been comminuted. It must be able to pass a screen with openings no greater than:

    Show answer

    Answer: B. Annex V Reg. 4 says comminuted or ground food waste must be capable of passing through a screen with openings no greater than 25 mm.

  21. 21
    TrapMARPOL Annex V Reg. 3

    A rating wants to put used cooking oil from the galley overboard 20 nm from land. What does Annex V say?

    Show answer

    Answer: B. Annex V prohibits discharge of cooking oil into the sea; it must be landed or handled as the Garbage Management Plan allows. Treating it as food waste is the trap: cooking oil is a separate garbage category.

  22. 22
    TrapMARPOL Annex V Reg. 4.3

    Food waste has been mixed with plastic bags in the galley bin. How must it be treated?

    Show answer

    Answer: D. When garbage is mixed with other garbage that has stricter requirements, the stricter requirement applies. Plastics may never be discharged, so the mixture goes ashore or is handled as plastic.

  23. 23
    DeeperMARPOL Annex V Reg. 10

    For how long must the Garbage Record Book be retained on board after the last entry?

    Show answer

    Answer: A. Annex V Reg. 10 requires the Garbage Record Book to be kept for at least two years after the last entry. Three years is the Oil Record Book period.

  24. 24
    DeeperMARPOL Annex V Reg. 10

    Which ships must display placards telling crew and passengers about the garbage discharge requirements?

    Show answer

    Answer: C. Annex V Reg. 10 requires placards on every ship of 12 m or more in length overall. The 100 GT / 15 persons threshold applies to the Garbage Management Plan, which is why it tempts.

  25. 25
    CoreMARPOL Annex VI Reg. 14

    What is the general limit on the sulphur content of fuel oil used on board outside an Emission Control Area?

    Show answer

    Answer: D. Annex VI Reg. 14 has set 0.50% m/m globally since 1 January 2020. 3.50% was the previous limit, and 0.10% applies inside SOx ECAs.

  26. 26
    CoreMARPOL Annex VI Reg. 14

    A ship without an exhaust gas cleaning system enters the North Sea ECA. What is the maximum sulphur content of the fuel it may burn?

    Show answer

    Answer: C. Inside a SOx ECA the limit under Annex VI Reg. 14 is 0.10% m/m. 0.50% is the global limit outside ECAs.

  27. 27
    TrapMARPOL Annex VI Reg. 14 and Appendix VII

    Which of these sea areas is a designated SOx Emission Control Area under MARPOL Annex VI?

    Show answer

    Answer: B. The Mediterranean became a SOx ECA with effect from 1 May 2025, joining the Baltic, North Sea, North American and US Caribbean ECAs. The Red Sea, Gulfs and Gulf of Aden are Annex I special areas, not Annex VI ECAs.

  28. 28
    DeeperMARPOL Annex VI Reg. 14

    Since 1 March 2020, what does Annex VI say about fuel oil above 0.50% sulphur on a ship with no scrubber?

    Show answer

    Answer: A. Resolution MEPC.305(73) added the carriage ban: a ship without an approved equivalent may not carry non-compliant fuel for combustion. Blending on board to reach an average is not a compliance method.

  29. 29
    DeeperMARPOL Annex VI Reg. 18.6 and 18.8

    For how long must a bunker delivery note be kept on board?

    Show answer

    Answer: A. Annex VI Reg. 18 requires the bunker delivery note to be kept on board for three years after delivery. 'Until consumed' is the rule for the representative fuel sample (kept at least 12 months), which is the trap.

  30. 30
    DeeperMARPOL Annex VI Reg. 13

    MARPOL Annex VI Reg. 13 (NOx) applies to which engines?

    Show answer

    Answer: B. Reg. 13 applies to each marine diesel engine with a power output of more than 130 kW, with listed exceptions such as engines used solely in emergencies. Tier III dates apply only within NOx ECAs.

  31. 31
    TrapMARPOL Annex VI Reg. 13

    Where do the Tier III NOx limits of Annex VI apply?

    Show answer

    Answer: C. Tier III is an ECA-only limit tied to construction dates (North American and US Caribbean ECAs from 2016, Baltic and North Sea from 2021). Outside NOx ECAs, Tier II applies to newer engines.

  32. 32
    DeeperMARPOL Annex VI Reg. 12

    A refrigeration contractor proposes fitting a new air-conditioning unit charged with an HCFC refrigerant in 2026. What does Annex VI say?

    Show answer

    Answer: D. Annex VI Reg. 12 prohibits new installations containing hydrochlorofluorocarbons on or after 1 January 2020. Recording ODS in a record book does not make a prohibited installation legal.

  33. 33
    DeeperMARPOL Annex VI Reg. 16

    Which of the following may NOT be incinerated in a shipboard incinerator under Annex VI?

    Show answer

    Answer: C. Annex VI Reg. 16 prohibits incineration of PCBs, Annex I, II and III cargo residues, garbage with more than traces of heavy metals and some other items. Sludge oil generated on board may be burned in an approved incinerator.

  34. 34
    TrapMARPOL Annex VI Reg. 28.6

    A ship's operational Carbon Intensity Indicator rating is D for the third consecutive year. What must the company do?

    Show answer

    Answer: A. Under the CII rules that took effect from 2023, a ship rated D for three consecutive years, or E in a single year, must develop a corrective action plan as part of the SEEMP. Ignoring a run of D ratings is the trap.

  35. 35
    CoreMARPOL Annex VI Reg. 6

    Which Annex VI certificate is issued to a ship of 400 GT and above engaged on international voyages after the air pollution survey?

    Show answer

    Answer: D. The IAPP Certificate is issued to the ship under Annex VI Reg. 6. The EIAPP Certificate is issued to an individual engine, which is why it tempts candidates.

  36. 36
    DeeperBWM Convention Reg. B-4

    Under the Ballast Water Management Convention, what are the preferred distance and depth for ballast water exchange (standard D-1)?

    Show answer

    Answer: B. Regulation B-4 of the BWM Convention asks for exchange at least 200 nm from land in at least 200 m depth, and if that is not possible at least 50 nm and 200 m. The D-2 discharge standard has replaced exchange for most ships.

  37. 37
    DeeperMARPOL Annex I Reg. 14

    Under Annex I Reg. 14, what equipment must a ship of 10,000 GT and above have for discharging machinery-space bilge water?

    Show answer

    Answer: B. Annex I Reg. 14 requires ships of 10,000 GT and above to have 15 ppm oil filtering equipment with an alarm and arrangements to stop the discharge automatically. The ODME is for tanker cargo-area discharges.

  38. 38
    TrapMARPOL Annex I Regs. 14, 15 and 17

    During the night watch the EOOW finds the overboard valve of the oily water separator open while the 15 ppm monitor shows a fault. What is the correct action?

    Show answer

    Answer: D. With the 15 ppm monitor not working, compliance with Reg. 15 cannot be shown, so discharge must stop and the event must be recorded (Oil Record Book Part I, including equipment failure). Bypassing the monitor is a serious MARPOL violation.

  39. 39
    DeeperMARPOL Annex I Reg. 34.1

    An oil tanker delivered in 2012 carried 90,000 tonnes of crude oil on its last voyage. Under Annex I, the total oil it may discharge into the sea from the cargo area on the ballast voyage is at most:

    Show answer

    Answer: A. For tankers delivered after 31 December 1979 the total must not exceed 1/30,000 of the cargo of which the residue formed part: 90,000 ÷ 30,000 = 3 tonnes. 6 tonnes uses the 1/15,000 figure for older tankers.

  40. 40
    CoreMARPOL Annex V Reg. 10.3 (as amended by MEPC.360(79))

    Since 1 May 2024, which ships must carry a Garbage Record Book under MARPOL Annex V?

    Show answer

    Answer: C. MEPC.360(79) lowered the threshold from 400 GT to 100 GT from 1 May 2024. 12 m length is the threshold for placards, not the record book; smaller ships record discharges in the official log book.

Reading answers is not the same as saying them. Our AI voice examiner asks these out loud, listens to your answer, asks the follow-up and marks you against the rule. Join early access or try the free timed mock oral drill.

Frequently asked questions

What is the 15 ppm rule in MARPOL?

Under MARPOL Annex I Reg. 15, a ship may discharge machinery-space bilge water only if the oil content without dilution does not exceed 15 parts per million. The ship must be en route and the water must pass through approved oil filtering equipment. The mixture must not come from cargo pump-room bilges or be mixed with cargo oil residues.

How many annexes does MARPOL have?

MARPOL has six annexes. Annex I covers oil, II noxious liquid substances in bulk, III harmful substances in packaged form, IV sewage, V garbage and VI air pollution and energy efficiency.

How long must the Oil Record Book be kept on board?

The Oil Record Book must be kept on board, readily available for inspection, for three years after the last entry. The Garbage Record Book is kept for two years after the last entry, which is a common trap.

Can garbage be thrown overboard in a special area?

Only a few types. In Annex V special areas, food waste may be discharged only when comminuted, the ship is en route and at least 12 nm from the nearest land or ice shelf. Plastics are banned everywhere, in or out of special areas.

What is the sulphur limit for marine fuel in 2026?

The global limit is 0.50% m/m, in force since 1 January 2020[1]. Inside a SOx Emission Control Area it is 0.10% m/m. A ship can use higher-sulphur fuel only with an approved equivalent such as an exhaust gas cleaning system.

Which sea areas are SOx Emission Control Areas?

The Baltic Sea, the North Sea, the North American area, the United States Caribbean Sea area and the Mediterranean Sea. The Mediterranean ECA took effect on 1 May 2025[2].

What are CII and EEXI?

EEXI is a one-time technical efficiency index for existing ships; CII is an annual operational carbon intensity rating from A to E. Both took effect from 1 January 2023[8]. A ship rated D three years running, or E once, must add a corrective action plan to its SEEMP.

What is the difference between Annex I Reg. 15 and Reg. 34?

Reg. 15 controls oily discharges from machinery spaces of all ships (15 ppm through oil filtering equipment). Reg. 34 controls discharges from the cargo area of oil tankers (more than 50 nm from land, at most 30 litres per nautical mile, ODME working, outside special areas).

What are the NLS categories under Annex II?

Category X is a major hazard and discharge into the sea is prohibited, so tanks are prewashed and residues go ashore. Category Y is a hazard and Category Z a minor hazard; both may be discharged under strict conditions. 'Other Substances' are outside X, Y and Z.

Is MARPOL asked in engineering orals?

Yes. MEO Class 4 and Class 2 candidates are asked about the oily water separator, the 15 ppm alarm, sludge, the Oil Record Book Part I, Annex VI fuel changeover and NOx tiers. Practise with this set and the oily water separator topic.

Are these the questions asked in the MMD or MCA exam?

No. We wrote every question ourselves from the text of MARPOL. They show the kind of question you should expect, not items from any exam paper. Use them to find gaps, then study the regulation.

How many questions should I get right before my exam?

Aim for 34 out of 40 or better on two runs a few days apart. Then practise speaking the same answers in the mock oral drill, because the oral tests whether you can explain, not just recognise.

Sources 8 documents

Each number in the text links to the source below. Labels show the type of source; see our editorial policy.

  1. Official IMO Resolution MEPC.176(58), revised MARPOL Annex VI, Reg. 14.1 and 14.4 · 10 October 2008
  2. Official IMO Resolution MEPC.361(79), Mediterranean Sea Emission Control Area for Sulphur Oxides and Particulate Matter · 16 December 2022
  3. Official IMO Resolution MEPC.305(73) · 26 October 2018
  4. Official IMO: Prevention of Pollution by Sewage from Ships
  5. Official IMO: Simplified overview of the discharge provisions of the revised MARPOL Annex V (in force 1 March 2018) · 13 June 2018
  6. Official REMPEC: Effective application of the Med SOx Emission Control Area under MARPOL Annex VI · 1 May 2025
  7. Official IMO Resolution MEPC.297(72), amendments to BWM Convention Reg. B-3 (implementation schedule) · 13 April 2018
  8. Official IMO press briefing: CII and EEXI entry into force · 1 November 2022

Where should you go next?

  • Question banks7 pages: free MCQ sets with answers and explanations
  • Oral topics14 pages: examiner questions with model answer points, deck and engine
  • CoC exam guides16 pages: every oral and written exam, authority by authority
  • Free tools4 pages: mock oral drill, lights trainer, sea-time calculator, practice tests
Exam Prep DeskMaritime exam researchers

We write from the conventions (STCW, COLREG, SOLAS, MARPOL), the authorities' own notices and published syllabi, and cite the source for every fee, rule and date. We are independent and not linked to any maritime administration or test provider. Found an error? It matters at sea: tell us and see how we correct · Disclaimer.

Related guides

AI voice mock oral

Say it out loud before the examiner asks.

Our examiner asks CoC oral questions by rank and function, listens to your answer, asks the follow-up and scores you against the rule. Early access is open for India first.

  • Deck and engine, every rank
  • Answers referenced to the conventions
  • Independent, not linked to any authority
WhatsApp us